Agenda

  1. Previous action items.
  2. Release of Spawn coupling.
  3. Kyle, Michael: Refactoring room air heat and mass balance.
  4. Kyle, Michael: EnergyPlus I/O variables.
  5. Michael, Kyle: Support for radiant systems.
  6. Stuart: FMI-QSS.
  7. Kyle, Michael: Optimica license protection.
  8. Jianjun: JSON representation for OS front-end to Modelica
  9. Other items

Participants

Kyle Benne
Michael Wetter

Minutes

Release of Spawn coupling

See milestones.

Refactoring room air balance

Issues are at https://github.com/lbl-srg/modelica-buildings/issues?q=is%3Aissue+is%3Aopen+label%3Aspawn

Next, work on

LBL AOP 9/30 (go/no-go): Release that can couple Modelica-based control to E+. OK to release in early 2021.

Kyle to work on emitting all EnergyPlus objects that are supported by Spawn.

Contract:

  1. If there is a thermal zone in Modelica, then there need to be a Zone object in the idf file. Otherwise the simulation stops with an error. EnergyPlus reports a Fatal Error to its error file and to the FMI API call.
  2. If there is an Zone object in the idf file but no thermal zone in Modelica for this EnergyPlus zone, then EnergyPlus simulates the zone using free floating temperature. There is no HVAC system, but may be internal gains. EnergyPlus reports an information message to its error file and to the FMI API call.
  3. All HVAC objects in the idf file will be removed by the Spawn executable before it writes the idf file to the FMU.
  4. For the EnergyPlus envelope, either the CTF transfer function or the finite difference method can be used.
  5. Output variables and EMS actuators need not be present in the idf file.

Radiant systems

Specfication at https://lbl-srg.github.io/soep/softwareArchitecture.html#coupling-of-a-zone-surface.

To be done in FY 21.

FMI-QSS

No discuss.

Optimica license protection

Michael works with Modelon on license protection.

JSON representation for OS front-end to Modelica

No discussion.

To do:

  • Handling replaceable models.

Other items

None.

New action items

None.

Previous action items

Michael to keep working with Modelon on making dp of pressure drop elements a state rather than p using stateSelect. Check tearing variables and make sure they don't go to zero.