Notifications
You must be signed in to change notification settings - Fork 52
NI RFmx SpecAn SEM Attributes
Alex Starche edited this page Feb 28, 2022
·
4 revisions
- RFMXSPECAN_ATTR_SEM_MEASUREMENT_ENABLED
- Carrier
-
Offset
- RFMXSPECAN_ATTR_SEM_NUMBER_OF_OFFSETS
- RFMXSPECAN_ATTR_SEM_OFFSET_ENABLED
- RFMXSPECAN_ATTR_SEM_OFFSET_START_FREQUENCY
- RFMXSPECAN_ATTR_SEM_OFFSET_STOP_FREQUENCY
- RFMXSPECAN_ATTR_SEM_OFFSET_SIDEBAND
- RBW Filter
- RFMXSPECAN_ATTR_SEM_OFFSET_BANDWIDTH_INTEGRAL
- RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_ATTENUATION
- RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK
- Absolute Limit
- Relative Limit
- RFMXSPECAN_ATTR_SEM_OFFSET_FREQUENCY_DEFINITION
- RFMXSPECAN_ATTR_SEM_POWER_UNITS
- RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE
- Sweep Time
- Averaging
- FFT
- RFMXSPECAN_ATTR_SEM_AMPLITUDE_CORRECTION_TYPE
- RFMXSPECAN_ATTR_SEM_ALL_TRACES_ENABLED
- RFMXSPECAN_ATTR_SEM_NUMBER_OF_ANALYSIS_THREADS
-
Results
- RFMXSPECAN_ATTR_SEM_RESULTS_TOTAL_CARRIER_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_COMPOSITE_MEASUREMENT_STATUS
- RFMXSPECAN_ATTR_SEM_RESULTS_FREQUENCY_RESOLUTION
-
Carrier
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_TOTAL_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_PEAK_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_PEAK_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_CARRIER_INTEGRATION_BANDWIDTH
-
Lower Offset
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_MEASUREMENT_STATUS
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_TOTAL_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_TOTAL_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_PEAK_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_PEAK_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_PEAK_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_MARGIN
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_MARGIN_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_MARGIN_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_MARGIN_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_START_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_STOP_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_LOWER_OFFSET_POWER_REFERENCE_CARRIER
-
Upper Offset
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_MEASUREMENT_STATUS
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_TOTAL_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_TOTAL_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_PEAK_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_PEAK_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_PEAK_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_MARGIN
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_MARGIN_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_MARGIN_RELATIVE_POWER
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_MARGIN_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_START_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_STOP_FREQUENCY
- RFMXSPECAN_ATTR_SEM_RESULTS_UPPER_OFFSET_POWER_REFERENCE_CARRIER
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the SEM measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_SEMGetMeasurementEnabled Set Function: RFmxSpecAn_SEMSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of carriers. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_SEMGetNumberOfCarriers Set Function: RFmxSpecAn_SEMSetNumberOfCarriers |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to consider the carrier power as part of the total carrier power measurement. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_ENABLED_TRUE. Get Function: RFmxSpecAn_SEMGetCarrierEnabled Set Function: RFmxSpecAn_SEMSetCarrierEnabled |
Values: |
RFMXSPECAN_VAL_SEM_ENABLED_FALSE (0) | The carrier power is not considered as part of the total carrier power. |
---|---|
RFMXSPECAN_VAL_SEM_ENABLED_TRUE (1) | The carrier power is considered as part of the total carrier power. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the center frequency of the carrier, relative to the RF center frequency. This value is expressed in Hz. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_SEMGetCarrierFrequency Set Function: RFmxSpecAn_SEMSetCarrierFrequency |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the frequency range over which the measurement integrates the carrier power. This value is expressed in Hz. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 2 MHz. Get Function: RFmxSpecAn_SEMGetCarrierIntegrationBandwidth Set Function: RFmxSpecAn_SEMSetCarrierIntegrationBandwidth |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | specifies the channel bandwidth of the carrier. This parameter is used to calculate the values of the RFMXSPECAN_ATTR_SEM_OFFSET_START_FREQUENCY and RFMXSPECAN_ATTR_SEM_OFFSET_STOP_FREQUENCY attributes when you set the RFMXSPECAN_ATTR_SEM_OFFSET_FREQUENCY_DEFINITION attribute to RFMXSPECAN_VAL_SEM_CARRIER_EDGE_TO_MEASUREMENT_BANDWIDTH_CENTER or RFMXSPECAN_VAL_SEM_CARRIER_EDGE_TO_MEASUREMENT_BANDWIDTH_EDGE. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 2 MHz. Get Function: RFmxSpecAn_SEMGetCarrierChannelBandwidth Set Function: RFmxSpecAn_SEMSetCarrierChannelBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes the resolution bandwidth (RBW) of the carrier. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_CARRIER_RBW_AUTO_TRUE. Get Function: RFmxSpecAn_SEMGetCarrierRBWFilterAutoBandwidth Set Function: RFmxSpecAn_SEMSetCarrierRBWFilterAutoBandwidth |
Values: |
RFMXSPECAN_VAL_SEM_CARRIER_RBW_AUTO_FALSE (0) | The measurement uses the RBW that you specify in the RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_BANDWIDTH attribute. |
---|---|
RFMXSPECAN_VAL_SEM_CARRIER_RBW_AUTO_TRUE (1) | The measurement computes the RBW. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired carrier signal, when you set the RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_AUTO_BANDWIDTH attribute to RFMXSPECAN_VAL_SEM_CARRIER_RBW_AUTO_FALSE. This value is expressed in Hz. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 10 kHz. Get Function: RFmxSpecAn_SEMGetCarrierRBWFilterBandwidth Set Function: RFmxSpecAn_SEMSetCarrierRBWFilterBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the shape of the digital resolution bandwidth (RBW) filter. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_TYPE_GAUSSIAN. Get Function: RFmxSpecAn_SEMGetCarrierRBWFilterType Set Function: RFmxSpecAn_SEMSetCarrierRBWFilterType |
Values: |
RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_TYPE_FFT_BASED (0) | No RBW filtering is performed. |
---|---|
RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_TYPE_GAUSSIAN (1) | The RBW filter has a Gaussian response. |
RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_TYPE_FLAT (2) | The RBW filter has a flat response. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the bandwidth definition that you use to specify the value of the RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_BANDWIDTH attribute. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_BANDWIDTH_DEFINITION_3DB. Get Function: RFmxSpecAn_SEMGetCarrierRBWFilterBandwidthDefinition Set Function: RFmxSpecAn_SEMSetCarrierRBWFilterBandwidthDefinition |
Values: |
RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_BANDWIDTH_DEFINITION_3DB (0) | Defines the RBW in terms of the 3 dB bandwidth of the RBW filter. When you set the RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_TYPE attribute to RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_TYPE_FFT_BASED, RBW is the 3 dB bandwidth of the window specified by the RFMXSPECAN_ATTR_SEM_FFT_WINDOW attribute. |
---|---|
RFMXSPECAN_VAL_SEM_CARRIER_RBW_FILTER_BANDWIDTH_DEFINITION_BIN_WIDTH (2) | Defines the RBW in terms of the spectrum bin width computed using an FFT when you set the RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_TYPE attribute to FFT Based. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to apply the root-raised-cosine (RRC) filter on the acquired carrier channel before measuring the carrier channel power. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_RRC_FILTER_ENABLED_FALSE. Get Function: RFmxSpecAn_SEMGetCarrierRRCFilterEnabled Set Function: RFmxSpecAn_SEMSetCarrierRRCFilterEnabled |
Values: |
RFMXSPECAN_VAL_SEM_RRC_FILTER_ENABLED_FALSE (0) | The channel power of the acquired carrier channel is measured directly. |
---|---|
RFMXSPECAN_VAL_SEM_RRC_FILTER_ENABLED_TRUE (1) | The measurement applies the RRC filter on the acquired carrier channel before measuring the carrier channel power. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the roll-off factor for the root-raised-cosine (RRC) filter to apply on the acquired carrier channel before measuring the carrier channel power. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 0.1. Get Function: RFmxSpecAn_SEMGetCarrierRRCFilterAlpha Set Function: RFmxSpecAn_SEMSetCarrierRRCFilterAlpha |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of offset segments. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_SEMGetNumberOfOffsets Set Function: RFmxSpecAn_SEMSetNumberOfOffsets |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the offset segment for SEM measurement. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_ENABLED_TRUE. Get Function: RFmxSpecAn_SEMGetOffsetEnabled Set Function: RFmxSpecAn_SEMSetOffsetEnabled |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_ENABLED_FALSE (0) | Disables the offset segment for the SEM measurement. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_ENABLED_TRUE (1) | Enables the offset segment for the SEM measurement. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the start frequency of the offset segment relative to the closest configured carrier channel bandwidth center or carrier channel bandwidth edge based on the value of the RFMXSPECAN_ATTR_SEM_OFFSET_FREQUENCY_DEFINITION attribute. This value is expressed in Hz. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 1 MHz. Get Function: RFmxSpecAn_SEMGetOffsetStartFrequency Set Function: RFmxSpecAn_SEMSetOffsetStartFrequency |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the stop frequency of the offset segment relative to the closest configured carrier channel bandwidth center or carrier channel bandwidth edge based on the value of the RFMXSPECAN_ATTR_SEM_OFFSET_FREQUENCY_DEFINITION attribute. This value is expressed in Hz. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 2 MHz. Get Function: RFmxSpecAn_SEMGetOffsetStopFrequency Set Function: RFmxSpecAn_SEMSetOffsetStopFrequency |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the offset segment is present on one side, or on both sides of the carrier. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_SIDEBAND_BOTH. Get Function: RFmxSpecAn_SEMGetOffsetSideband Set Function: RFmxSpecAn_SEMSetOffsetSideband |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_SIDEBAND_NEGATIVE (0) | Configures a lower offset segment to the left of the leftmost carrier. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_SIDEBAND_POSITIVE (1) | Configures an upper offset segment to the right of the rightmost carrier. |
RFMXSPECAN_VAL_SEM_OFFSET_SIDEBAND_BOTH (2) | Configures both negative and positive offset segments. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes the resolution bandwidth (RBW). Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_RBW_AUTO_TRUE. Get Function: RFmxSpecAn_SEMGetOffsetRBWFilterAutoBandwidth Set Function: RFmxSpecAn_SEMSetOffsetRBWFilterAutoBandwidth |
Values: |
RFMXSPECAN_VAL_SEM_RBW_AUTO_FALSE (0) | The measurement uses the RBW that you specify in the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_BANDWIDTH attribute. |
---|---|
RFMXSPECAN_VAL_SEM_RBW_AUTO_TRUE (1) | The measurement computes the RBW. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired offset segment, when you set the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_AUTO_BANDWIDTH attribute to RFMXSPECAN_VAL_SEM_RBW_AUTO_FALSE. This value is expressed in Hz. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 10 kHz. Get Function: RFmxSpecAn_SEMGetOffsetRBWFilterBandwidth Set Function: RFmxSpecAn_SEMSetOffsetRBWFilterBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the shape of the digital resolution bandwidth (RBW) filter. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_RBW_FILTER_TYPE_GAUSSIAN. Get Function: RFmxSpecAn_SEMGetOffsetRBWFilterType Set Function: RFmxSpecAn_SEMSetOffsetRBWFilterType |
Values: |
RFMXSPECAN_VAL_SEM_RBW_FILTER_TYPE_FFT_BASED (0) | No RBW filtering is performed. |
---|---|
RFMXSPECAN_VAL_SEM_RBW_FILTER_TYPE_GAUSSIAN (1) | The RBW filter has a Gaussian response. |
RFMXSPECAN_VAL_SEM_RBW_FILTER_TYPE_FLAT (2) | The RBW filter has a flat response. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the bandwidth definition which you use to specify the value of the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_BANDWIDTH attribute. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_RBW_FILTER_BANDWIDTH_DEFINITION_3DB. Get Function: RFmxSpecAn_SEMGetOffsetRBWFilterBandwidthDefinition Set Function: RFmxSpecAn_SEMSetOffsetRBWFilterBandwidthDefinition |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_RBW_FILTER_BANDWIDTH_DEFINITION_3DB (0) | Defines the RBW in terms of the 3dB bandwidth of the RBW filter. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_TYPE attribute to RFMXSPECAN_VAL_SEM_RBW_FILTER_TYPE_FFT_BASED, RBW is the 3dB bandwidth of the window specified by the RFMXSPECAN_ATTR_SEM_FFT_WINDOW attribute. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_RBW_FILTER_BANDWIDTH_DEFINITION_BIN_WIDTH (2) | Defines the RBW in terms of the spectrum bin width computed using FFT when you set the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_TYPE attribute to FFT Based. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the resolution of the spectrum to compare with spectral mask limits as an integer multiple of the resolution bandwidth (RBW). If you set this attribute to a value greater than 1, the measurement acquires the spectrum with a narrow resolution and then processes it digitally to get a wider resolution that is equal to the product of the bandwidth integral and the RBW. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 1. Get Function: RFmxSpecAn_SEMGetOffsetBandwidthIntegral Set Function: RFmxSpecAn_SEMSetOffsetBandwidthIntegral |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the attenuation relative to the external attenuation specified by the RFMXSPECAN_ATTR_EXTERNAL_ATTENUATION attribute. This value is expressed in dB. Use the SEM Offset Rel Attn attribute to compensate for the variations in external attenuation when offset segments are spread wide in frequency. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_SEMGetOffsetRelativeAttenuation Set Function: RFmxSpecAn_SEMSetOffsetRelativeAttenuation |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the criteria to determine the measurement fail status. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_LIMIT_FAIL_MASK_ABSOLUTE_AND_RELATIVE. Get Function: RFmxSpecAn_SEMGetOffsetLimitFailMask Set Function: RFmxSpecAn_SEMSetOffsetLimitFailMask |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_LIMIT_FAIL_MASK_ABSOLUTE_AND_RELATIVE (0) | The measurement fails if the power in the segment exceeds both the absolute and relative masks. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_LIMIT_FAIL_MASK_ABSOLUTE_OR_RELATIVE (1) | The measurement fails if the power in the segment exceeds either the absolute or relative mask. |
RFMXSPECAN_VAL_SEM_OFFSET_LIMIT_FAIL_MASK_ABSOLUTE (2) | The measurement fails if the power in the segment exceeds the absolute mask. |
RFMXSPECAN_VAL_SEM_OFFSET_LIMIT_FAIL_MASK_RELATIVE (3) | The measurement fails if the power in the segment exceeds the relative mask. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the absolute limit mask is a flat line or a line with a slope. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_ABSOLUTE_LIMIT_MODE_COUPLE. Get Function: RFmxSpecAn_SEMGetOffsetAbsoluteLimitMode Set Function: RFmxSpecAn_SEMSetOffsetAbsoluteLimitMode |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_ABSOLUTE_LIMIT_MODE_MANUAL (0) | The line specified by the RFMXSPECAN_ATTR_SEM_OFFSET_ABSOLUTE_LIMIT_START and RFMXSPECAN_ATTR_SEM_OFFSET_ABSOLUTE_LIMIT_STOP attribute values as the two ends is considered as the mask. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_ABSOLUTE_LIMIT_MODE_COUPLE (1) | The two ends of the line are coupled to the value of the RFMXSPECAN_ATTR_SEM_OFFSET_ABSOLUTE_LIMIT_START attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the absolute power limit corresponding to the beginning of the offset segment. This value is expressed in dBm. This power limit is also set as the stop limit for the offset segment when you set the RFMXSPECAN_ATTR_SEM_OFFSET_ABSOLUTE_LIMIT_MODE attribute to RFMXSPECAN_VAL_SEM_OFFSET_ABSOLUTE_LIMIT_MODE_COUPLE. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is -10. Get Function: RFmxSpecAn_SEMGetOffsetAbsoluteLimitStart Set Function: RFmxSpecAn_SEMSetOffsetAbsoluteLimitStart |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the absolute power limit corresponding to the end of the offset segment. This value is expressed in dBm. The measurement ignores this attribute when you set the RFMXSPECAN_ATTR_SEM_OFFSET_ABSOLUTE_LIMIT_MODE attribute to RFMXSPECAN_VAL_SEM_OFFSET_ABSOLUTE_LIMIT_MODE_COUPLE. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is -10. Get Function: RFmxSpecAn_SEMGetOffsetAbsoluteLimitStop Set Function: RFmxSpecAn_SEMSetOffsetAbsoluteLimitStop |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the relative limit mask is a flat line or a line with a slope. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_SEM_OFFSET_RELATIVE_LIMIT_MODE_MANUAL. Get Function: RFmxSpecAn_SEMGetOffsetRelativeLimitMode Set Function: RFmxSpecAn_SEMSetOffsetRelativeLimitMode |
Values: |
RFMXSPECAN_VAL_SEM_OFFSET_RELATIVE_LIMIT_MODE_MANUAL (0) | The line specified by the RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_LIMIT_START and RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_LIMIT_STOP attribute values as the two ends is considered as the mask. |
---|---|
RFMXSPECAN_VAL_SEM_OFFSET_RELATIVE_LIMIT_MODE_COUPLE (1) | The two ends of the line are coupled to the value of the RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_LIMIT_START attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the relative power limit corresponding to the beginning of the offset segment. This value is expressed in dB. This power limit is also set as the stop limit for the offset segment when you set the RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_LIMIT_MODE attribute to RFMXSPECAN_VAL_SEM_OFFSET_RELATIVE_LIMIT_MODE_COUPLE. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is -20. Get Function: RFmxSpecAn_SEMGetOffsetRelativeLimitStart Set Function: RFmxSpecAn_SEMSetOffsetRelativeLimitStart |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the relative power limit corresponding to the end of the offset segment. This value is expressed in dB. The measurement ignores this attribute when you set the RFMXSPECAN_ATTR_SEM_OFFSET_RELATIVE_LIMIT_MODE attribute to RFMXSPECAN_VAL_SEM_OFFSET_RELATIVE_LIMIT_MODE_COUPLE. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is -30. Get Function: RFmxSpecAn_SEMGetOffsetRelativeLimitStop Set Function: RFmxSpecAn_SEMSetOffsetRelativeLimitStop |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the definition of the start frequency and stop frequency of the offset segments from the nearest carrier channels. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is Carrier Center to Meas BW Center. Get Function: RFmxSpecAn_SEMGetOffsetFrequencyDefinition Set Function: RFmxSpecAn_SEMSetOffsetFrequencyDefinition |
Values: |
RFMXSPECAN_VAL_SEM_CARRIER_CENTER_TO_MEASUREMENT_BANDWIDTH_CENTER (0) | The start frequency and stop frequency are defined from the center of the closest carrier channel bandwidth to the center of the offset segment measurement bandwidth. Measurement Bandwidth = Resolution Bandwidth * Bandwidth Integral. |
---|---|
RFMXSPECAN_VAL_SEM_CARRIER_CENTER_TO_MEASUREMENT_BANDWIDTH_EDGE (1) | The start frequency and stop frequency are defined from the center of the closest carrier channel bandwidth to the nearest edge of the offset segment measurement bandwidth. |
RFMXSPECAN_VAL_SEM_CARRIER_EDGE_TO_MEASUREMENT_BANDWIDTH_CENTER (2) | The start frequency and stop frequency are defined from the nearest edge of the closest carrier channel bandwidth to the center of the nearest offset segment measurement bandwidth. |
RFMXSPECAN_VAL_SEM_CARRIER_EDGE_TO_MEASUREMENT_BANDWIDTH_EDGE (3) | The start frequency and stop frequency are defined from the nearest edge of the closest carrier channel bandwidth to the edge of the nearest offset segment measurement bandwidth. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the units for the absolute power. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Get Function: RFmxSpecAn_SEMGetPowerUnits Set Function: RFmxSpecAn_SEMSetPowerUnits |
Values: |
RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM (0) | The absolute powers are reported in dBm. |
---|---|
RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ (1) | The absolute powers are reported in dBm/Hz. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the power reference is the integrated power or the peak power in the closest carrier channel. The leftmost carrier is the carrier closest to all the lower (negative) offset segments. The rightmost carrier is the carrier closest to all the upper (positive) offset segments. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION. Get Function: RFmxSpecAn_SEMGetReferenceType Set Function: RFmxSpecAn_SEMSetReferenceType |
Values: |
RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION (0) | The power reference is the integrated power of the closest carrier. |
---|---|
RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_PEAK (1) | The power reference is the peak power of the closest carrier. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_SWEEP_TIME_AUTO_TRUE. Get Function: RFmxSpecAn_SEMGetSweepTimeAuto Set Function: RFmxSpecAn_SEMSetSweepTimeAuto |
Values: |
RFMXSPECAN_VAL_SEM_SWEEP_TIME_AUTO_FALSE (0) | The measurement uses the sweep time that you specify in the RFMXSPECAN_ATTR_SEM_SWEEP_TIME_INTERVAL attribute. |
---|---|
RFMXSPECAN_VAL_SEM_SWEEP_TIME_AUTO_TRUE (1) | The measurement calculates the sweep time based on the value of the RFMXSPECAN_ATTR_SEM_OFFSET_RBW_FILTER_BANDWIDTH and RFMXSPECAN_ATTR_SEM_CARRIER_RBW_FILTER_BANDWIDTH attributes. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the sweep time when you set the RFMXSPECAN_ATTR_SEM_SWEEP_TIME_AUTO attribute to RFMXSPECAN_VAL_SEM_SWEEP_TIME_AUTO_FALSE. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0.001. Get Function: RFmxSpecAn_SEMGetSweepTimeInterval Set Function: RFmxSpecAn_SEMSetSweepTimeInterval |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable averaging for the SEM measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_AVERAGING_ENABLED_FALSE. Get Function: RFmxSpecAn_SEMGetAveragingEnabled Set Function: RFmxSpecAn_SEMSetAveragingEnabled |
Values: |
RFMXSPECAN_VAL_SEM_AVERAGING_ENABLED_FALSE (0) | The measurement is performed on a single acquisition. |
---|---|
RFMXSPECAN_VAL_SEM_AVERAGING_ENABLED_TRUE (1) | The SEM measurement uses the RFMXSPECAN_ATTR_SEM_AVERAGING_COUNT attribute as the number of acquisitions over which the SEM measurement is averaged. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of acquisitions used for averaging when you set the RFMXSPECAN_ATTR_SEM_AVERAGING_ENABLED attribute to RFMXSPECAN_VAL_SEM_AVERAGING_ENABLED_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxSpecAn_SEMGetAveragingCount Set Function: RFmxSpecAn_SEMSetAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for SEM measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_RMS. Get Function: RFmxSpecAn_SEMGetAveragingType Set Function: RFmxSpecAn_SEMSetAveragingType |
Values: |
RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. |
---|---|
RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_LOG (1) | The power spectrum is averaged in a logarithmic scale. |
RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_SCALAR (2) | The square root of the power spectrum is averaged. |
RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_MAXIMUM (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. |
RFMXSPECAN_VAL_SEM_AVERAGING_TYPE_MINIMUM (4) | The least power in the spectrum at each frequency bin is retained from one acquisition to the next. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the FFT window type to use to reduce spectral leakage. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_FFT_WINDOW_FLAT_TOP. Get Function: RFmxSpecAn_SEMGetFFTWindow Set Function: RFmxSpecAn_SEMSetFFTWindow |
Values: |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_NONE (0) | Analyzes transients for which duration is shorter than the window length. You can also use this window type to separate two tones with frequencies close to each other but with almost equal amplitudes. |
---|---|
RFMXSPECAN_VAL_SEM_FFT_WINDOW_FLAT_TOP (1) | Measures single-tone amplitudes accurately. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_HANNING (2) | Analyzes transients for which duration is longer than the window length. You can also use this window type to provide better frequency resolution for noise measurements. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_HAMMING (3) | Analyzes closely-spaced sine waves. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_GAUSSIAN (4) | Provides a good balance of spectral leakage, frequency resolution, and amplitude attenuation. Hence, this windowing is useful for time-frequency analysis. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_BLACKMAN (5) | Analyzes single tone because it has a low maximum side lobe level and a high side lobe roll-off rate. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_BLACKMAN_HARRIS (6) | Useful as a good general purpose window, having side lobe rejection greater than 90 dB and having a moderately wide main lobe. |
RFMXSPECAN_VAL_SEM_FFT_WINDOW_KAISER_BESSEL (7) | Separates two tones with frequencies close to each other but with widely-differing amplitudes. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the factor by which the time-domain waveform is zero-padded before FFT. The FFT size is given by the following formula: waveform size * padding This attribute is used only when the acquisition span is less than the device instantaneous bandwidth of the device. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is -1. Get Function: RFmxSpecAn_SEMGetFFTPadding Set Function: RFmxSpecAn_SEMSetFFTPadding |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the RFmxInstr_CfgExternalAttenuationTable function to configure the external attenuation table. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_SEM_AMPLITUDE_CORRECTION_TYPE_RF_CENTER_FREQUENCY. Get Function: RFmxSpecAn_SEMGetAmplitudeCorrectionType Set Function: RFmxSpecAn_SEMSetAmplitudeCorrectionType |
Values: |
RFMXSPECAN_VAL_SEM_AMPLITUDE_CORRECTION_TYPE_RF_CENTER_FREQUENCY (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the RF center frequency. |
---|---|
RFMXSPECAN_VAL_SEM_AMPLITUDE_CORRECTION_TYPE_SPECTRUM_FREQUENCY_BIN (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that frequency. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the SEM measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_SEMGetAllTracesEnabled Set Function: RFmxSpecAn_SEMSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for SEM measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_SEMGetNumberOfAnalysisThreads Set Function: RFmxSpecAn_SEMSetNumberOfAnalysisThreads |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the total integrated power, in dBm, of all the enabled carriers measured when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM. Returns the power spectral density, in dBm/Hz, when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_SEMGetResultsTotalCarrierPower |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Indicates the overall measurement status based on the measurement limits and the fail criteria that you set in the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute for each offset segment. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_SEMGetResultsCompositeMeasurementStatus |
Values: |
RFMXSPECAN_VAL_SEM_COMPOSITE_MEASUREMENT_STATUS_FAIL (0) | Indicates that the measurement has failed. |
---|---|
RFMXSPECAN_VAL_SEM_COMPOSITE_MEASUREMENT_STATUS_PASS (1) | Indicates that the measurement has passed. |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency bin spacing of the spectrum acquired by the measurement. This value is expressed in Hz. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_SEMGetResultsFrequencyResolution |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the carrier power relative to the total carrier power of all enabled carriers. This value is expressed in dB. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierTotalRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the carrier power. The carrier power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the peak power in the carrier channel. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierPeakAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency at which the peak power occurs in the carrier channel. This value is expressed in Hz. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierPeakFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the center frequency of the carrier relative to the Center Frequency attribute. This value is expressed in Hz. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency range, over which the measurement integrates the carrier power. This value is expressed in Hz. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsCarrierIntegrationBandwidth |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Indicates the lower offset segment measurement status based on measurement limits and the fail criteria that you specify in the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetMeasurementStatus |
Values: |
RFMXSPECAN_VAL_SEM_LOWER_OFFSET_MEASUREMENT_STATUS_FAIL (0) | Indicates that the measurement has failed. |
---|---|
RFMXSPECAN_VAL_SEM_LOWER_OFFSET_MEASUREMENT_STATUS_PASS (1) | Indicates that the measurement has passed. |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power measured in the lower (negative) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetTotalAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power measured in the lower (negative) offset segment relative to either the integrated or peak power of the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION, the reference carrier power is the total power in the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_PEAK, the reference carrier power is the peak power in the reference carrier. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetTotalRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the peak power measured in the lower (negative) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetPeakAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the peak power measured in the lower (negative) offset segment relative to the integrated or peak power of the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION, the reference carrier power is the total power in the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_PEAK, the reference carrier power is the peak power in the reference carrier. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetPeakRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency at which the peak power occurred in the lower offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetPeakFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the margin from the limit mask value that you set in the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute. This value is expressed in dB. Margin is defined as the maximum difference between the spectrum and the limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Absolute, the margin is with reference to the absolute limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Relative, the margin is with reference to the relative limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Abs AND Rel, the margin is the maximum of the margins referenced to the absolute and relative limit masks. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Abs OR Rel, the margin is the minimum of the margins referenced to the absolute and relative limit masks. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power, at which the margin occurred in the lower (negative) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetMarginAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power at which the margin occurred in the lower (negative) offset segment relative to the integrated or peak power of the reference carrier. This value is expressed in dB. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetMarginRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency at which the margin occurred in the lower (negative) offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetMarginFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the start frequency of the lower (negative) offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetStartFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the stop frequency of the lower (negative) offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetStopFrequency |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier that was used as the power reference to define the lower (negative) offset segment relative power. The reference carrier is the carrier that has an offset closest to the offset segment. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsLowerOffsetPowerReferenceCarrier |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Indicates the upper offset measurement status based on measurement limits and the fail criteria that you specify in the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetMeasurementStatus |
Values: |
RFMXSPECAN_VAL_SEM_UPPER_OFFSET_MEASUREMENT_STATUS_FAIL (0) | Indicates that the measurement has failed. |
---|---|
RFMXSPECAN_VAL_SEM_UPPER_OFFSET_MEASUREMENT_STATUS_PASS (1) | Indicates that the measurement has passed. |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the offset segment power measured in the upper (positive) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetTotalAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power measured in the upper (positive) offset segment relative to the integrated or peak power of the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION, the reference carrier power is the total power in the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_PEAK, the reference carrier power is the peak power in the reference. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetTotalRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the peak power measured in the upper (positive) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetPeakAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the peak power measured in the upper (positive) offset segment relative to the integrated or peak power of the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_INTEGRATION, the reference carrier power is the total power in the reference carrier. When you set the RFMXSPECAN_ATTR_SEM_REFERENCE_TYPE attribute to RFMXSPECAN_VAL_SEM_REFERENCE_TYPE_PEAK, the reference carrier power is the peak power in the reference carrier. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetPeakRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency at which the peak power occurred in the upper offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetPeakFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the margin from the limit mask value that you set in the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute. This value is expressed in dB. Margin is defined as the maximum difference between the spectrum and the limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Absolute, the margin is with reference to the absolute limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Relative, the margin is with reference to the relative limit mask. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Abs AND Rel, the margin is the maximum of the margin referenced to the absolute and relative limit masks. When you set the RFMXSPECAN_ATTR_SEM_OFFSET_LIMIT_FAIL_MASK attribute to Abs OR Rel, the margin is the minimum of the margin referenced to the absolute and relative limit masks. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power, at which the margin occurred in the upper (positive) offset segment. The power is reported in dBm when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_SEM_POWER_UNITS attribute to RFMXSPECAN_VAL_SEM_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetMarginAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the power at which the margin occurred in the upper (positive) offset segment relative to the integrated or peak power of the reference carrier. This value is expressed in dB. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetMarginRelativePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency at which the margin occurred in the upper (positive) offset. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetMarginFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the start frequency of the upper (positive) offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetStartFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the stop frequency of the upper (positive) offset segment. This value is expressed in Hz. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetStopFrequency |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier that was used as the power reference to define the upper (positive) offset segment relative power. The reference carrier is the carrier that has an offset closest to the offset segment. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_SEMGetResultsUpperOffsetPowerReferenceCarrier |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions