- RFMXLTE_ATTR_MODACC_MEASUREMENT_ENABLED
- RFMXLTE_ATTR_MODACC_MULTICARRIER_FILTER_ENABLED
- RFMXLTE_ATTR_MODACC_SYNCHRONIZATION_MODE
- RFMXLTE_ATTR_MODACC_MEASUREMENT_OFFSET
- RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH
- IQ Impairmenets
- RFMXLTE_ATTR_MODACC_SPECTRUM_INVERTED
- RFMXLTE_ATTR_MODACC_CHANNEL_ESTIMATION_TYPE
- RFMXLTE_ATTR_MODACC_EVM_UNIT
- RFMXLTE_ATTR_MODACC_FFT_WINDOW_TYPE
- RFMXLTE_ATTR_MODACC_FFT_WINDOW_OFFSET
- RFMXLTE_ATTR_MODACC_FFT_WINDOW_LENGTH
- RFMXLTE_ATTR_MODACC_COMMON_CLOCK_SOURCE_ENABLED
- RFMXLTE_ATTR_MODACC_EVM_WITH_EXCLUSION_PERIOD_ENABLED
- RFMXLTE_ATTR_MODACC_SPECTRAL_FLATNESS_CONDITION
- RFMXLTE_ATTR_MODACC_IN_BAND_EMISSION_MASK_TYPE
- Averaging
- RFMXLTE_ATTR_MODACC_ALL_TRACES_ENABLED
- RFMXLTE_ATTR_MODACC_NUMBER_OF_ANALYSIS_THREADS
-
Results
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_COMPOSITE_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MAXIMUM_PEAK_COMPOSITE_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_COMPOSITE_MAGNITUDE_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_MAXIMUM_PEAK_COMPOSITE_MAGNITUDE_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_COMPOSITE_PHASE_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_MAXIMUM_PEAK_COMPOSITE_PHASE_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_PEAK_COMPOSITE_EVM_SLOT_INDEX
- RFMXLTE_ATTR_MODACC_RESULTS_PEAK_COMPOSITE_EVM_SYMBOL_INDEX
- RFMXLTE_ATTR_MODACC_RESULTS_PEAK_COMPOSITE_EVM_SUBCARRIER_INDEX
-
Downlink
-
PDSCH
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_QPSK_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_16QAM_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_64QAM_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_256QAM_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PDSCH_MEAN_RMS_1024QAM_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_CSRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PSS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_SSS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PBCH_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PCFICH_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PDCCH_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PHICH_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_DOWNLINK_RS_TRANSMIT_POWER
- RFMXLTE_ATTR_MODACC_RESULTS_DOWNLINK_OFDM_SYMBOL_TRANSMIT_POWER
- RFMXLTE_ATTR_MODACC_RESULTS_DOWNLINK_DETECTED_CELL_ID
-
PDSCH
- RFMXLTE_ATTR_MODACC_RESULTS_IN_BAND_EMISSION_MARGIN
- Spectral Flatness
-
Uplink
-
PUSCH
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MEAN_RMS_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MAXIMUM_PEAK_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MEAN_RMS_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MAXIMUM_PEAK_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MEAN_DATA_POWER
- RFMXLTE_ATTR_MODACC_RESULTS_PUSCH_MEAN_DMRS_POWER
- SRS
-
NPUSCH
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MEAN_RMS_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MAXIMUM_PEAK_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MEAN_RMS_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MAXIMUM_PEAK_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MEAN_DATA_POWER
- RFMXLTE_ATTR_MODACC_RESULTS_NPUSCH_MEAN_DMRS_POWER
- Spectral Flatness
- RFMXLTE_ATTR_MODACC_RESULTS_SUBBLOCK_IN_BAND_EMISSION_MARGIN
-
PUSCH
-
Sidelink
-
PSSCH
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MEAN_RMS_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MAXIMUM_PEAK_DATA_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MEAN_RMS_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MAXIMUM_PEAK_DMRS_EVM
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MEAN_DATA_POWER
- RFMXLTE_ATTR_MODACC_RESULTS_PSSCH_MEAN_DMRS_POWER
-
PSSCH
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_FREQUENCY_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_IQ_ORIGIN_OFFSET
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_IQ_GAIN_IMBALANCE
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_QUADRATURE_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_IQ_TIMING_SKEW
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_TIME_OFFSET
- RFMXLTE_ATTR_MODACC_RESULTS_MEAN_SYMBOL_CLOCK_ERROR
- RFMXLTE_ATTR_MODACC_RESULTS_SUBBLOCK_MEAN_IQ_ORIGIN_OFFSET
- RFMXLTE_ATTR_MODACC_RESULTS_SUBBLOCK_MEAN_IQ_GAIN_IMBALANCE
- RFMXLTE_ATTR_MODACC_RESULTS_SUBBLOCK_MEAN_QUADRATURE_ERROR
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_FALSE. Get Function: RFmxLTE_ModAccGetMeasurementEnabled Set Function: RFmxLTE_ModAccSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to use a filter to suppress the interference from out of band emissions into the carriers being measured. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetMulticarrierFilterEnabled Set Function: RFmxLTE_ModAccSetMulticarrierFilterEnabled |
Values: |
RFMXLTE_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_FALSE (0) | The measurement does not use the multicarrier filter. |
---|---|
RFMXLTE_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_TRUE (1) | The measurement filters out interference from out of band emissions into the carriers being measured. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether the measurement is performed from the frame or the slot boundary. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. Refer to the LTE Modulation Accuracy (ModAcc) topic for more information about synchronization mode. The default value is RFMXLTE_VAL_MODACC_SYNCHRONIZATION_MODE_SLOT. When you set the Link Direction attribute to Downlink, the measurement supports only Frame synchronization mode. Get Function: RFmxLTE_ModAccGetSynchronizationMode Set Function: RFmxLTE_ModAccSetSynchronizationMode |
Values: |
RFMXLTE_VAL_MODACC_SYNCHRONIZATION_MODE_FRAME (0) | The frame boundary is detected, and the measurement is performed over the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute, starting at the RFMXLTE_ATTR_MODACC_MEASUREMENT_OFFSET attribute from the frame boundary. When you set the RFMXLTE_ATTR_TRIGGER_TYPE attribute to RFMXLTE_VAL_TRIGGER_TYPE_DIGITAL_EDGE, the measurement expects a trigger at the frame boundary. |
---|---|
RFMXLTE_VAL_MODACC_SYNCHRONIZATION_MODE_SLOT (1) | The slot boundary is detected, and the measurement is performed over the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute starting at the RFMXLTE_ATTR_MODACC_MEASUREMENT_OFFSET attribute from the slot boundary. When you set the RFMXLTE_ATTR_TRIGGER_TYPE attribute to Digital Edge, the measurement expects a trigger at any slot boundary. |
RFMXLTE_VAL_MODACC_SYNCHRONIZATION_MODE_MARKER (2) | The measurement expects a marker (trigger) at the frame boundary from the user. The measurement takes advantage of triggered acquisitions to reduce processing resulting in faster measurement time. Measurement is performed over the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute starting at RFMXLTE_ATTR_MODACC_MEASUREMENT_OFFSET attribute from the frame boundary. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the measurement offset to skip from the synchronization boundary. The synchronization boundary is specified by the RFMXLTE_ATTR_MODACC_SYNCHRONIZATION_MODE attribute. This value is expressed in slots. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0. For uplink, the upper limit is 19. For downlink, the upper limit is (2*DL Num Subframe - 1). Get Function: RFmxLTE_ModAccGetMeasurementOffset Set Function: RFmxLTE_ModAccSetMeasurementOffset |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the number of slots to be measured. This value is expressed in slots. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxLTE_ModAccGetMeasurementLength Set Function: RFmxLTE_ModAccSetMeasurementLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to estimate IQ origin offset. Note: IQ origin offset estimation is supported only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK or RFMXLTE_VAL_LINK_DIRECTION_SIDELINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_IQ_ORIGIN_OFFSET_ESTIMATION_ENABLED_TRUE. Get Function: RFmxLTE_ModAccGetIQOriginOffsetEstimationEnabled Set Function: RFmxLTE_ModAccSetIQOriginOffsetEstimationEnabled |
Values: |
RFMXLTE_VAL_MODACC_IQ_ORIGIN_OFFSET_ESTIMATION_ENABLED_FALSE (0) | IQ origin offset estimation and correction is disabled. |
---|---|
RFMXLTE_VAL_MODACC_IQ_ORIGIN_OFFSET_ESTIMATION_ENABLED_TRUE (1) | IQ origin offset estimation and correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to estimate IQ mismatch such as gain imbalance, quadrature skew, and timing skew. Note: Timing skew value is estimated only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_TRUE. Get Function: RFmxLTE_ModAccGetIQMismatchEstimationEnabled Set Function: RFmxLTE_ModAccSetIQMismatchEstimationEnabled |
Values: |
RFMXLTE_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_FALSE (0) | IQ mismatch estimation is disabled. |
---|---|
RFMXLTE_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_TRUE (1) | IQ mismatch estimation is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable IQ gain imbalance correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetIQGainImbalanceCorrectionEnabled Set Function: RFmxLTE_ModAccSetIQGainImbalanceCorrectionEnabled |
Values: |
RFMXLTE_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_FALSE (0) | IQ gain imbalance correction is disabled. |
---|---|
RFMXLTE_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_TRUE (1) | IQ gain imbalance correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable IQ quadrature error correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetIQQuadratureErrorCorrectionEnabled Set Function: RFmxLTE_ModAccSetIQQuadratureErrorCorrectionEnabled |
Values: |
RFMXLTE_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_FALSE (0) | IQ quadrature error correction is disabled. |
---|---|
RFMXLTE_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_TRUE (1) | IQ quadrature error correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable IQ timing skew correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetIQTimingSkewCorrectionEnabled Set Function: RFmxLTE_ModAccSetIQTimingSkewCorrectionEnabled |
Values: |
RFMXLTE_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_FALSE (0) | IQ timing skew correction is disabled. |
---|---|
RFMXLTE_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_TRUE (1) | IQ timing skew correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether the spectrum of the measured signal is inverted. The inversion happens when the I and the Q components of the baseband complex signal are swapped. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_SPECTRUM_INVERTED_FALSE. Get Function: RFmxLTE_ModAccGetSpectrumInverted Set Function: RFmxLTE_ModAccSetSpectrumInverted |
Values: |
RFMXLTE_VAL_MODACC_SPECTRUM_INVERTED_FALSE (0) | The spectrum of the measured signal is not inverted. |
---|---|
RFMXLTE_VAL_MODACC_SPECTRUM_INVERTED_TRUE (1) | The measured signal is inverted and the measurement corrects the signal by swapping the I and the Q components. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the method used for the channel estimation for the ModAcc measurement. The measurement ignores this attribute, when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_DOWNLINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is Reference+Data. Get Function: RFmxLTE_ModAccGetChannelEstimationType Set Function: RFmxLTE_ModAccSetChannelEstimationType |
Values: |
RFMXLTE_VAL_MODACC_CHANNEL_ESTIMATION_TYPE_REFERENCE (0) | Only the demodulation reference signal (DMRS) symbol is used to calculate the channel coefficients. |
---|---|
RFMXLTE_VAL_MODACC_CHANNEL_ESTIMATION_TYPE_REFERENCE_AND_DATA (1) | Both the DMRS symbol and the data symbol are used to calculate the channel coefficients, as specified by the 3GPP 36.521 specification, Annexe E. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the units of the EVM results. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE. Get Function: RFmxLTE_ModAccGetEVMUnit Set Function: RFmxLTE_ModAccSetEVMUnit |
Values: |
RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE (0) | The EVM is reported as a percentage. |
---|---|
RFMXLTE_VAL_MODACC_EVM_UNIT_DB (1) | The EVM is reported in dB. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the FFT window type used for the EVM calculation for the ModAcc measurement. Refer to the LTE Modulation Accuracy (ModAcc) topic for more information about FFT window type. The default value is RFMXLTE_VAL_MODACC_FFT_WINDOW_TYPE_CUSTOM. Get Function: RFmxLTE_ModAccGetFFTWindowType Set Function: RFmxLTE_ModAccSetFFTWindowType |
Values: |
RFMXLTE_VAL_MODACC_FFT_WINDOW_TYPE_3GPP (0) | The maximum EVM between the start window position and the end window position is returned according to the 3GPP specification. The FFT window positions are specified by the attribute. Refer to the Annexe E.3.2 of 3GPP TS 36.521 specification for more information on the FFT window. |
---|---|
RFMXLTE_VAL_MODACC_FFT_WINDOW_TYPE_CUSTOM (1) | Only one FFT window position is used for the EVM calculation. FFT window position is specified by RFMXLTE_ATTR_MODACC_FFT_WINDOW_OFFSET attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeF64 RFmxLTE_GetAttributeF64 |
Description: | Specifies the position of the FFT window used to calculate the EVM. The offset is expressed as a percentage of the cyclic prefix length. If you set this attribute to 0, the EVM window starts at the end of cyclic prefix. If you set this attribute to 100, the EVM window starts at the beginning of cyclic prefix. The default value is 50. Valid values are 0 to 100, inclusive. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. Get Function: RFmxLTE_ModAccGetFFTWindowOffset Set Function: RFmxLTE_ModAccSetFFTWindowOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeF64 RFmxLTE_GetAttributeF64 |
Description: | Specifies the FFT window length (W). This value is expressed as a percentage of the cyclic prefix length. This attribute is used when you set the RFMXLTE_ATTR_MODACC_FFT_WINDOW_TYPE attribute to RFMXLTE_VAL_MODACC_FFT_WINDOW_TYPE_3GPP, where it is needed to calculate the EVM using two different FFT window positions, Delta_C-W/2, and Delta_C+W/2. Refer to the Annexe E.3.2 of 3GPP 36.521 specification for more information. Refer to the LTE Modulation Accuracy (ModAcc) topic for more information about FFT Window Length. The default value is as given in the 3GPP specification. The default value is 91.7 %CP for 10M bandwidth. Valid values range from -1 to 100, inclusive. When this attribute is set to -1, RFmx populates the FFT Window Length based on carrier bandwidth automatically, as given in the Annexe E.5.1 of 3GPP 36.104 specification. Get Function: RFmxLTE_ModAccGetFFTWindowLength Set Function: RFmxLTE_ModAccSetFFTWindowLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether the same Reference Clock is used for the local oscillator and the digital-to-analog converter in the transmitter. When the same Reference Clock is used, the carrier frequency offset is proportional to Sample Clock error. The modacc measurement ignores this attribute, when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_DOWNLINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_TRUE. Get Function: RFmxLTE_ModAccGetCommonClockSourceEnabled Set Function: RFmxLTE_ModAccSetCommonClockSourceEnabled |
Values: |
RFMXLTE_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_FALSE (0) | The Sample Clock error is estimated independently. |
---|---|
RFMXLTE_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_TRUE (1) | The Sample Clock error is estimated from carrier frequency offset. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to exclude some portion of the slots when calculating the EVM. This attribute is applicable only when there is a power change at the slot boundary. Refer to section 6.5.2.1A of the 3GPP TS 36.521-1 specification for more information about exclusion. The measurement ignores this attribute, when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_DOWNLINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_EVM_WITH_EXCLUSION_PERIOD_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetEVMWithExclusionPeriodEnabled Set Function: RFmxLTE_ModAccSetEVMWithExclusionPeriodEnabled |
Values: |
RFMXLTE_VAL_MODACC_EVM_WITH_EXCLUSION_PERIOD_ENABLED_FALSE (0) | EVM is calculated on complete slots. |
---|---|
RFMXLTE_VAL_MODACC_EVM_WITH_EXCLUSION_PERIOD_ENABLED_TRUE (1) | EVM is calculated on truncated slots. The power changes at the slot boundaries are detected by the measurement, and the defined 3GPP specification period is excluded from the slots being measured. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the frequency ranges at which to measure spectral flatness. The measurement ignores this attribute, when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_DOWNLINK. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_NORMAL. Get Function: RFmxLTE_ModAccGetSpectralFlatnessCondition Set Function: RFmxLTE_ModAccSetSpectralFlatnessCondition |
Values: |
RFMXLTE_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_NORMAL (0) | Uses the frequency range defined in the section 6.5.2.4.5, and table 6.5.2.4.3-1 of 3GPP 36.521 specification. |
---|---|
RFMXLTE_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_EXTREME (1) | Uses the frequency range defined in the section 6.5.2.4.5, and table 6.5.2.4.3-2 of 3GPP 36.521 specification. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the in-band emissions mask type to be used for measuring in-band emission margin (dB) and subblock in-Band emission margin (dB) results. Refer to section 6.5.2.3.5 of the 3GPP 36.521-1 specification for more information. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is Release 8-10 for bandwidths other than 200 KHz and RFMXLTE_ATTR_EMTC_ANALYSIS_ENABLED is False. It is Release 11 Onwards, otherwise. Get Function: RFmxLTE_ModAccGetInBandEmissionMaskType Set Function: RFmxLTE_ModAccSetInBandEmissionMaskType |
Values: |
RFMXLTE_VAL_MODACC_IN_BAND_EMISSION_MASK_TYPE_RELEASE_8_10 (0) | Specifies the mask type to be used for UE, supporting 3GPP Release 8 to 3GPP Release 10 specification. |
---|---|
RFMXLTE_VAL_MODACC_IN_BAND_EMISSION_MASK_TYPE_RELEASE_11_ONWARDS (1) | Specifies the mask type to be used for UE, supporting 3GPP Release 11 and higher specification. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable averaging for the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_MODACC_AVERAGING_ENABLED_FALSE. Get Function: RFmxLTE_ModAccGetAveragingEnabled Set Function: RFmxLTE_ModAccSetAveragingEnabled |
Values: |
RFMXLTE_VAL_MODACC_AVERAGING_ENABLED_FALSE (0) | The measurement is performed on a single acquisition. |
---|---|
RFMXLTE_VAL_MODACC_AVERAGING_ENABLED_TRUE (1) | The measurement is averaged over multiple acquisitions. The number of acquisitions is obtained by the RFMXLTE_ATTR_MODACC_AVERAGING_COUNT attribute. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the number of acquisitions used for averaging when you set the RFMXLTE_ATTR_MODACC_AVERAGING_ENABLED attribute to RFMXLTE_VAL_MODACC_AVERAGING_ENABLED_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxLTE_ModAccGetAveragingCount Set Function: RFmxLTE_ModAccSetAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_FALSE. Get Function: RFmxLTE_ModAccGetAllTracesEnabled Set Function: RFmxLTE_ModAccSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for the ModAcc measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxLTE_ModAccGetNumberOfAnalysisThreads Set Function: RFmxLTE_ModAccSetNumberOfAnalysisThreads |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the RMS EVMs calculated on all the configured channels, over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsMeanRMSCompositeEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of the peak EVMs calculated on all the configured channels over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMaximumPeakCompositeEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the RMS mean value of the composite magnitude error calculated over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute on all the configured channels. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSCompositeMagnitudeError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak value of the composite magnitude error calculated over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute on all the configured channels. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMaximumPeakCompositeMagnitudeError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the RMS mean value of the composite phase error calculated over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute on all the configured channels. This value is expressed in degrees. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSCompositePhaseError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak value of phase error calculated over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute on all thee configured channels. This value is expressed in degrees. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMaximumPeakCompositePhaseError |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeI32 |
Description: | Returns the slot index where the ModAcc maximum peak composite EVM occurs. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPeakCompositeEVMSlotIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeI32 |
Description: | Returns the symbol index of the RFMXLTE_ATTR_MODACC_RESULTS_MAXIMUM_PEAK_COMPOSITE_EVM attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPeakCompositeEVMSymbolIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeI32 |
Description: | Returns the subcarrier index where the maximum peak composite EVM for ModAcc occurs. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPeakCompositeEVMSubcarrierIndex |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on PDSCH data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on all QPSK modulated PDSCH resource blocks over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMSQPSKEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on all 16QAM modulated PDSCH resource blocks over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMS16QAMEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on all 64 QAM modulated PDSCH resource blocks over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMS64QAMEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on all 256 QAM modulated PDSCH resource blocks over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMS256QAMEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on all 1024 QAM modulated PDSCH resource blocks over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPDSCHMeanRMS1024QAMEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on RS resource elements over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSCSRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on primary synchronization signal (PSS) channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSPSSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on secondary synchronization signal (SSS) channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSSSSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on PBCH channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSPBCHEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on PCFICH channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSPCFICHEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on PDCCH channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSPDCCHEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on PHICH channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSPHICHEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of power calculated on cell-specific reference signal (CSRS) resource elements over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsDownlinkRSTransmitPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of power calculated in one OFDM symbol over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsDownlinkOFDMSymbolTransmitPower |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeI32 |
Description: | Returns the detected cell ID value. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsDownlinkDetectedCellID |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the in-band emission margin. This value is expressed in dB. The margin is the lowest difference between the in-band emission measurement trace and the limit trace. The limit is defined in section 6.5.2.3.5 of the 3GPP TS 36.521 specification. The in-band emissions are a measure of the interference falling into the non-allocated resources blocks. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsInBandEmissionMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients within the frequency Range1. This value is expressed in dB. The frequency Range1 is defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSpectralFlatnessRange1MaximumToRange1Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients within the frequency Measurement Offset parameter. This value is expressed in dB. The frequency Measurement Offset parameter is defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSpectralFlatnessRange2MaximumToRange2Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients from the frequency Range1 to the frequency Measurement Offset parameter. The frequency Range1 and frequency Measurement Offset parameter are defined in the section 6.5.2.4.5 of the 3GPP TS 36.521 specification. This value is expressed in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSpectralFlatnessRange1MaximumToRange2Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the RMS EVMs calculated on the physical uplink shared channel (PUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPUSCHMeanRMSDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of the peak EVMs calculated on the physical uplink shared channel (PUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPUSCHMaximumPeakDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the RMS EVMs calculated on the PUSCH DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPUSCHMeanRMSDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of the peak EVMs calculated on PUSCH DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPUSCHMaximumPeakDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the physical uplink shared channel (PUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPUSCHMeanDataPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the PUSCH DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPUSCHMeanDMRSPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on the SRS symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanRMSSRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of power calculated on SRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This values is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanSRSPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on the narrowband physical uplink shared channel (NPUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to percentage, the result is returned as a percentage, and when you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the result is returned in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMeanRMSDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated on the narrowband physical uplink shared channel (NPUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to percentage, the result is returned as a percentage, and when you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the result is returned in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. The default value is 0. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMaximumPeakDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated on the narrowband physical uplink shared channel (NPUSCH) DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the result is returned as a percentage, and when you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the result is returned in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. The default value is 0. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMeanRMSDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated on NPUSCH DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the result is returned as a percentage, and when you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the result is returned in dB. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. The default value is 0. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMaximumPeakDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the narrowband physical uplink shared channel (NPUSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. The default value is 0. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMeanDataPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the narrowband physical uplink shared channel (NPUSCH) DMRS over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxLTE_ModAccGetResultsNPUSCHMeanDMRSPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients from frequency Measurement Offset parameter to frequency Range1. This value is expressed in dB. The frequency Range1 and frequency Measurement Offset parameter are defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSpectralFlatnessRange2MaximumToRange1Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the in-band emission margin of a subblock aggregated bandwidth. This value is expressed in dB. The margin is the lowest difference between the in-band emission measurement trace and the limit trace. The limit is defined in section 6.5.2A.3 of the 3GPP TS 36.521 specification. The in-band emissions are a measure of the interference falling into the non-allocated resources blocks. The result of this attribute is valid only when you set the RFMXLTE_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXLTE_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Use 'subblock(n)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSubblockInBandEmissionMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the RMS EVMs calculated on the physical sidelink shared channel (PSSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPSSCHMeanRMSDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of the peak EVMs calculated on the physical sidelink shared channel (PSSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPSSCHMaximumPeakDataEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the RMS EVMs calculated on the PSSCH DMRS symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPSSCHMeanRMSDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the maximum value of the peak EVMs calculated on PSSCH DMRS symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to RFMXLTE_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Get Function: RFmxLTE_ModAccGetResultsPSSCHMaximumPeakDMRSEVM |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the physical sidelink shared channel (PSSCH) data symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPSSCHMeanDataPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the mean value of the power calculated on the PSSCH DMRS symbols over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsPSSCHMeanDMRSPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated carrier frequency offset averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in Hz. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanFrequencyError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated I/Q origin offset averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dBc. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK. This result will not be measured in case of downlink. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanIQOriginOffset |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated I/Q gain imbalance averaged over the measurement length. The I/Q gain imbalance is the ratio of the amplitude of the I component to the Q component of the I/Q signal being measured. This value is expressed in dB. Note: When you set the RFMXLTE_ATTR_COMPONENT_CARRIER_BANDWIDTH attribute to 200.0 k and the RFMXLTE_ATTR_NPUSCH_NUMBER_OF_TONES attribute to 12, this result is available. For other values of RFMXLTE_ATTR_NPUSCH_NUMBER_OF_TONES, this result will be reported as NaN. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanIQGainImbalance |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated quadrature error averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in degrees. Quadrature error is a measure of the skewness of the I component with respect to the Q component of the I/Q signal being measured. When you set the RFMXLTE_ATTR_COMPONENT_CARRIER_BANDWIDTH attribute to 200.0 k and the RFMXLTE_ATTR_NPUSCH_NUMBER_OF_TONES attribute to 12, this result is available. For other values of RFMXLTE_ATTR_NPUSCH_NUMBER_OF_TONES, this result will be reported as NaN. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanQuadratureError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated IQ timing skew averaged over measured length. IQ timing skew is the difference between the group delay of the in-phase (I) and quadrature (Q) components of the signal. This value is expressed in seconds. Use 'carrier' or 'subblock/carrier' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanIQTimingSkew |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the time difference between the detected slot or frame boundary and the reference trigger location depending on the value of RFMXLTE_ATTR_MODACC_SYNCHRONIZATION_MODE attribute. This value is expressed in seconds. Use 'carrier' or 'subblock/carrier' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanTimeOffset |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated symbol clock error averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in ppm. Use 'carrier(k)' or 'subblock(n)/carrier(k)' as the selector string to read this result. Use 'carrier' or 'subblock/carrier' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsMeanSymbolClockError |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated I/Q origin offset averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute in the subblock. This value is expressed in dBc. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK and the RFMXLTE_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXLTE_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Use 'subblock(n)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSubblockMeanIQOriginOffset |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated I/Q gain imbalance averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in dB. The I/Q gain imbalance is the ratio of the amplitude of the I component to the Q component of the I/Q signal being measured in the subblock. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK and the RFMXLTE_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXLTE_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Otherwise, this parameter returns NaN, as measurement of this result is currently not supported. Use 'subblock(n)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSubblockMeanIQGainImbalance |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxLTE_GetAttributeF64 |
Description: | Returns the estimated quadrature error averaged over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute. This value is expressed in degrees. Quadrature error is a measure of the skewness of the I component with respect to the Q component of the I/Q signal being measured in the subblock. This result is valid only when you set the RFMXLTE_ATTR_LINK_DIRECTION attribute to RFMXLTE_VAL_LINK_DIRECTION_UPLINK and the RFMXLTE_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXLTE_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Otherwise, this parameter returns NaN, as measurement of this result is currently not supported. Use 'subblock(n)' as the selector string to read this result. Get Function: RFmxLTE_ModAccGetResultsSubblockMeanQuadratureError |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions