-
Notifications
You must be signed in to change notification settings - Fork 52
NI RFmx SpecAn PAVT Attributes
Alex Starche edited this page Feb 28, 2022
·
4 revisions
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_ENABLED
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LOCATION_TYPE
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_BANDWIDTH
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE
- RFMXSPECAN_ATTR_PAVT_NUMBER_OF_SEGMENTS
- RFMXSPECAN_ATTR_PAVT_SEGMENT_TYPE
- RFMXSPECAN_ATTR_PAVT_SEGMENT_START_TIME
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_OFFSET
- RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LENGTH
- RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_OFFSET
- RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_LENGTH
- RFMXSPECAN_ATTR_PAVT_PHASE_UNWRAP_ENABLED
- RFMXSPECAN_ATTR_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED
- RFMXSPECAN_ATTR_PAVT_FREQUENCY_TRACKING_ENABLED
- RFMXSPECAN_ATTR_PAVT_ALL_TRACES_ENABLED
- Results
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the Phase Amplitude Versus Time (PAVT) measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_PAVTGetMeasurementEnabled Set Function: RFmxSpecAn_PAVTSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the location at which the segment is measured is indicated by time or trigger. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME. Get Function: RFmxSpecAn_PAVTGetMeasurementLocationType Set Function: RFmxSpecAn_PAVTSetMeasurementLocationType |
Values: |
RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME (0) | The measurement is performed over a single record across multiple segments separated in time. The measurement locations of the segments are specified by the RFMXSPECAN_ATTR_PAVT_SEGMENT_START_TIME attribute. The number of segments is equal to the number of segment start times. |
---|---|
RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TRIGGER (1) | The measurement is performed across segments obtained in multiple records, where each record is obtained when a trigger is received. The number of segments is equal to the number of triggers (records). |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the bandwidth over which the signal is measured. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10 MHz. Get Function: RFmxSpecAn_PAVTGetMeasurementBandwidth Set Function: RFmxSpecAn_PAVTSetMeasurementBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the mode of configuring the measurement interval. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM. Get Function: RFmxSpecAn_PAVTGetMeasurementIntervalMode Set Function: RFmxSpecAn_PAVTSetMeasurementIntervalMode |
Values: |
RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM (0) | The time offset from the start of segment and the duration over which the measurement is performed is uniform for all segments and is given by the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_OFFSET attribute and the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LENGTH attribute respectively. |
---|---|
RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE (1) | The time offset from the start of segment and the duration over which the measurement is performed is configured separately for each segment and is given by the RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_OFFSET attribute and the RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_LENGTH attribute respectively. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of segments to be measured. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_PAVTGetNumberOfSegments Set Function: RFmxSpecAn_PAVTSetNumberOfSegments |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the type of segment. Use 'segment(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE. Get Function: RFmxSpecAn_PAVTGetSegmentType Set Function: RFmxSpecAn_PAVTSetSegmentType |
Values: |
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE (0) | Phase and amplitude is measured in this segment. |
---|---|
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_AMPLITUDE (1) | Amplitude is measured in this segment. |
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_FREQUENCY_ERROR_MEASUREMENT (2) | Frequency error is measured in this segment. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the start time of measurement of the segments. This value is expressed in seconds. You can use this attribute only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LOCATION_TYPE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME. Use 'segment(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_PAVTGetSegmentStartTime Set Function: RFmxSpecAn_PAVTSetSegmentStartTime |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the time offset from the start of the segment for which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0. Get Function: RFmxSpecAn_PAVTGetMeasurementOffset Set Function: RFmxSpecAn_PAVTSetMeasurementOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the duration within the segment over which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1 millisecond. Get Function: RFmxSpecAn_PAVTGetMeasurementLength Set Function: RFmxSpecAn_PAVTSetMeasurementLength |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the time offset from the start of the segment for which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE. Use 'segment(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_PAVTGetSegmentMeasurementOffset Set Function: RFmxSpecAn_PAVTSetSegmentMeasurementOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the duration within each segment over which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE. Use 'segment(n)' as the selector string to configure or read this attribute. The default value is 1 millisecond. Get Function: RFmxSpecAn_PAVTGetSegmentMeasurementLength Set Function: RFmxSpecAn_PAVTSetSegmentMeasurementLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the phase measurement results are unwrapped or wrapped. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_FALSE. Get Function: RFmxSpecAn_PAVTGetPhaseUnwrapEnabled Set Function: RFmxSpecAn_PAVTSetPhaseUnwrapEnabled |
Values: |
RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_FALSE (0) | Phase measurement results are wrapped within +/-180 degrees. |
---|---|
RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_TRUE (1) | Phase measurement results are unwrapped. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable frequency offset correction for the measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_FALSE. Get Function: RFmxSpecAn_PAVTGetFrequencyOffsetCorrectionEnabled Set Function: RFmxSpecAn_PAVTSetFrequencyOffsetCorrectionEnabled |
Values: |
RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_FALSE (0) | Disables the frequency offset correction. |
---|---|
RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_TRUE (1) | Enables the frequency offset correction. The measurement computes and corrects any frequency offset between the reference and the acquired waveforms. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable frequency offset correction per segment for the measurement. While you set this attribute to RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_TRUE, ensure that the RFMXSPECAN_ATTR_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED attribute is set to RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_TRUE and the RFMXSPECAN_ATTR_PAVT_SEGMENT_TYPE attribute is set to RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_FALSE. Get Function: RFmxSpecAn_PAVTGetFrequencyTrackingEnabled Set Function: RFmxSpecAn_PAVTSetFrequencyTrackingEnabled |
Values: |
RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_FALSE (0) | Disables the drift correction for the measurement. |
---|---|
RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_TRUE (1) | Enables the drift correction. The measurement corrects and reports the frequency offset per segment. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the PAVT measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_PAVTGetAllTracesEnabled Set Function: RFmxSpecAn_PAVTSetAllTracesEnabled |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean phase of the segment, relative to the phase of the reference segment. This value is expressed in degrees. Use 'segment(n)' as the selector string to read this result. Get Function: RFmxSpecAn_PAVTGetResultsMeanRelativePhase |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean amplitude of the segment, relative to the amplitude of the reference segment. This value is expressed in dB. Mean Relative Amplitude = ai - ar ai is the absolute amplitude of the segment i, expressed in dBm ar is the absolute amplitude of the reference segment r, expressed in dBm where, r = 1, if Segment0 is configured as Frequency Error Measurement segment r = 0, otherwise Use 'segment(n)' as the selector string to read this result. Get Function: RFmxSpecAn_PAVTGetResultsMeanRelativeAmplitude |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean absolute phase of the segment. This value is expressed in degrees. Use 'segment(n)' as the selector string to read this result. Get Function: RFmxSpecAn_PAVTGetResultsMeanAbsolutePhase |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean absolute amplitude of the segment. This value is expressed in dBm. Use 'segment(n)' as the selector string to read this result. Get Function: RFmxSpecAn_PAVTGetResultsMeanAbsoluteAmplitude |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean frequency error of the segment. This value is expressed in Hz Use 'segment(n)' as the selector string to read this result. Get Function: RFmxSpecAn_PAVTGetResultsFrequencyErrorMean |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions