Notifications
You must be signed in to change notification settings - Fork 114
digital read pulse width
Read a digital pulse width. Use the Stimulus input to specify a pulse type to send before measuring the response pulse.
Stimulus Pulse (Active High)
Specifies the polarity of the stimulus pulse as None, Active High, or Acitve Low.
Incoming Pulse Polarity (Active High)
Specifies the polarity of the incoming pulse as Active High or Active Low.
LINX Resource
Contains LINX connection resources.
DI Channel
Specifies the digital input channel on which to measure the pulse.
DO Channel
(Optional) Specifies the digital output channel on which to generate the stimulus pulse (if any)
Error In
Describes error conditions that occur before this node runs. This input provides standard error in functionality.
Timeout (250 mS)
Specifies the amount of time to wait for the incoming pulse to begin.
LINX Resource
Contains LINX connection resources.
Pulse Width (uS)
Returns the measured pulse width in uS.
Error Out