Servo Servo Set Pulse Width One Channel

Set the pulse width of the specified servo channel.

A pulse width of 1500uS is typically the center point of rotation (90 degrees). Most servos can rotate between 1000 and 2000 uS but the actual limits will vary depending on the specific servo.

servo-set-pulse-width-one-channel.png

Inputs

LINX Resource

Contains LINX connection resources.

Servo Channel

Specifies the LINX device servo channel to update.

Pulse Width (uS)

Specifies the pulse width in uS to send to the servo. A pulse width of 1500uS is typically the center point of rotation (90 degrees). Most servos can rotate between 1000 and 2000 uS but the actual limits will vary depending on the specific servo.

Error In

Describes error conditions that occur before this node runs. This input provides standard error in functionality.

Outputs

LINX Resource

Contains LINX connection resources.

Error Out

Contains error information. This output provides standard error out functionality.