[Buffer] Added cable length config to buffer config template for EdgeZoneAggregator #14280
[Buffer] Added cable length config to buffer config template for EdgeZoneAggregator #14280
Conversation
@@ -0,0 +1,2869 @@ | |||
<DeviceMiniGraph xmlns="Microsoft.Search.Autopilot.Evolution" xmlns:i="http://www.w3.org/2001/XMLSchema-instance"> |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
can you model Arista-7060CX-32S-D48C8 instead? That is the hwsku that connects to EdgeZoneAggregator
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Ok
</ManagementAddress> | ||
<HwSku>Arista-VM</HwSku> | ||
</Device> | ||
<Device i:type="LeafRouter"> |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Make all the neighbors of type EdgeZoneAggregator
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Ok, but this has no effect on cable length since the rest of the neighbors are all leaf routers.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This is just to mimic actual environment where all neighbors are EdgeZone devices
Signed-off-by: dojha <[email protected]>
Signed-off-by: dojha <[email protected]>
@developfast , I think this change cannot be cleanly cherry-picked into 202012. Please check and raise a separate PR if needed |
@developfast PR conflicts with 202205 branch |
…ZoneAggregator (sonic-net#14280) Why I did it SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1. How I did it Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router. How to verify it Unit tests pass, and manually checked on a 7260 to see the changes take effect. Signed-off-by: dojha <[email protected]>
Cherry-pick PR to 202211: #14340 |
…ZoneAggregator (#14280) Why I did it SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1. How I did it Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router. How to verify it Unit tests pass, and manually checked on a 7260 to see the changes take effect. Signed-off-by: dojha <[email protected]>
…for EdgeZoneAggregator (#14539) #### Why I did it SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1. Original PR for master: #14280 #### How I did it Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router. #### How to verify it Unit tests pass, and manually checked on a 7260 to see the changes take effect. #### Description for the changelog [Buffer] Added cable length config to buffer config template for EdgeZoneAggregator
Why I did it
SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1.
How I did it
Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router.
How to verify it
Unit tests pass, and manually checked on a 7260 to see the changes take effect.
Which release branch to backport (provide reason below if selected)
Description for the changelog
[Buffer] Added cable length config to buffer config template for EdgeZoneAggregator