Fix calibration using jointCalibrationSolution #348

Merged
merged 1 commit into from
Apr 4, 2023
Merged

Conversation

lrapetti
Copy link
Member

@lrapetti lrapetti commented Apr 4, 2023

In #341, after the code review we have introduced a bug and the calibration was no longer performed correctly.

The problem was that the jointCalibrationSolution was never used, while the current configuration (jointConfigurationSolution) was used to calibrate the joints. This PR fix the bug

@lrapetti lrapetti requested a review from RiccardoGrieco as a code owner April 4, 2023 10:25
@lrapetti lrapetti requested a review from dariosortino April 4, 2023 10:25
@lrapetti lrapetti self-assigned this Apr 4, 2023
Copy link
Contributor

@RiccardoGrieco RiccardoGrieco left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LGTM

@lrapetti lrapetti merged commit aee6863 into master Apr 4, 2023
@lrapetti lrapetti deleted the fix-calibration branch April 4, 2023 12:31