Some subsystems inside the Portapack would benefit from some sort of temperature compensation being added into the code, as discussed in the original Portapack Github repository with it's developer.
Such need gave birth to the Portapack temperature logger, accessible from DEBUG->Temperature menu options.
Temperature data is provided by the MAX2837 On-Chip Digital Temperature Sensor. MAX2837 Datasheet can be found here.
But, if you read the discussion about it on the earlier Github link, the temperature precision on the MAX2837 is too coarse (about +/- 5ºC) to be really useful.
This is why jboone, the Portapack creator, finally decided this value had no real use and thus the temperature widget further development / refinement and usage enhancement was dropped.
Monitoring MAX2837 temperature is important because it's VCO (Voltage Controlled Oscillator) is able to maintain lock only while inside +/- 40ºC variation from ambient temperature.
NOTE: The MAX 2837 operating temperature range goes from -40ºC to +85ºC.
This sensor can be activated and read through the SPI interface. By accessing the TEMP_SENSE register we can read the ADC output with a precision of 5 bits.
The datasheet provides the following reference values:
TA = +25ºC -> 01111 (DEC 15)
TA = +85ºC -> 11101 (DEC 29)
TA = -40ºC -> 00001 (DEC 1)
In short, the temp sensor inside MAX2837 returns a decimal number between 1 and 29 for a -40ºC to +85ºC temperature range, which would put the precision on about 4.33ºC per each value.
NOTE: As Jboone stated on the Github link provided above, this is definitely a coarse precision value.
This is accomplished on /firmware/application/hw/max2837.cpp
with the following code:
reg_t MAX2837::temp_sense() {
if( !_map.r.rx_top.ts_en ) {
_map.r.rx_top.ts_en = 1;
flush_one(Register::RX_TOP);
chThdSleepMilliseconds(1);
}
_map.r.rx_top.ts_adc_trigger = 1;
flush_one(Register::RX_TOP);
halPolledDelay(ticks_for_temperature_sense_adc_conversion);
const auto value = read(Register::TEMP_SENSE);
_map.r.rx_top.ts_adc_trigger = 0;
flush_one(Register::RX_TOP);
return value;
}
The above code follows the max2837 datasheet's Temperature Sensor Readout Through DOUT Pin procedure, which includes the following steps:
-
Enable on-chip temperature sensor by setting address 9 (RX_TOP), register 1 (ts_en) with value 1.
-
Wait a while ( suggested 100us to 1ms, Portapack code waits 1ms) for the sensor to stabilize and settle within 5 to 1 ºC precision.
-
Trigger the ADC conversion by setting RX_TOP register 0 (ts_adc_trigger) with value 1
-
According to the max2837 datasheet, the ADC will acquire the temperature value in 2us time (but as we follow the definition of ticks_for_temperature_sense_adc_conversion we find a comment in Portapack's code stating a wait of 25 us -shrug-).
-
Get the temperature by reading address 7 (TEMP_SENSE)
-
Finally, turn off the ADC converter by setting address RX_TOP, register ts_adc_trigger with value 0
The logging code functions can be found at /firmware/application/temperature_logger.cpp
.
There is an array uint8_t samples dimensioned for 128 temperature values. The sample_interval is set at 5 seconds between each read_sample().
The m0 events dispatcher handle_rtc_tick located at /fimrware/application/event_m0.cpp
taps periodically into the function second_tick(). When the number of seconds defined by sample_interval is reached, the temperature is measured and pushed into the samples array.
The temperature graph widget is defined on /firmware/application/apps/ui_debug.cpp
.
It should graph the 128 temperature values, stored on the samples arrray. On the botton right side of the graph, it shows the most recent logged value.
Warning: Here is when things get weird (for me at least). The Temperature Widget seems to be wrong ("Spoiler": Later I learn it is ok):
-
First, the temperature graph had the y axis going from 0ºC to 60ºC (which at first glance is not aligned with MAX2837 temp data output, going from -40ºC to 85ºC).
-
Secondly, when plotting each temperature value, the original sensor value is processed through the following function:
return -45 + sensor_value * 5;
which seems a bit off, particularly when tested against the Ambient Reference sensor value of 15 (for 25ºC) according to the MAX2837 Datasheet.
I bypassed the ºC conversion functionality in order to watch the raw decimal value being returned by the MAX2837 On-Chip Digital Temperature Sensor. My test room temperature is about 22ºC
Portapack is on, in iddle mode and the sensor returns a value of 9 . If converted into ºC, such value should correspond to a temperature of about 0 / 1 ºC, which seems to be wrong. Portapack aluminium case is at about 26.7ºC.
I placed my Portapack in transmit mode, loop-playing a random earlier captured radio sample for about 30 minutes. The exterior aluminium case is at about 31.4ºC.
Right after stopping the transmission, the sensor value is 10. We give it about 10 seconds and the value drops to 9. But Portapacks aluminium case is still about 31.4ºC.
I placed my Portapack outside, where it cooled down for about 30 minutes (Temperature outside is about 15ºC).
Back inside, I powered it up and got a first sensor value of 7, which would correspond to -10ºC. Portapack's case temp was about 15ºC
About a minute later the sensor value increased by one, returning 8, which should correspond to -5ºC. Portapack's case temp was about 20ºC
My observation indicates that MAX2832 temperature sensor is NOT giving out an absolute temp value (It reflects neither the ambient temperature inside the Portapack, nor an on-chip temperature).
At first glance, this sensor value might be the relative temperature change (increase) between ambient temperature (Which goes up when Portapack is transmitting, as evidenced on the aluminium case external measurement) and the MAX2837 temperature itself.
So what could be wrong ? Consider the following:
- MAX2837 Datasheet may be wrong
- I am not correctly interpreting the MAX2837 description for the On-Chip Digital Temperature Sensor
- Portapack's code might have a bug and reading are wrong
After more code delving, a conclusion is reached: MAX2837 documentation is failing to correctly explain the On-Chip Digital Temperature Sensor values.
Apparently, the sensor returns the temperature difference between ambient temperature and MAX2837 temperature!
Note
The wiki is incomplete. Please add content and collaborate.
Important
- This is a public wiki. Everything is visible to everyone. Don't use it for personal notes.
- Avoid linking to external tutorials/articles; they may become outdated or contain false information.
How to collaborate
How to ask questions correctly
- First steps
- Usage cautions
- Intended use and Legality
- Features
- PortaPack Versions (which one to buy)
- HackRF Versions
- Firmware update procedure
- Description of the hardware
- User interface
- Powering the PortaPack
-
Troubleshooting
- Won't boot
- Config Menu
- Firmware upgrade
- Diagnose firmware update in Windows
- Receive Quality Issues
- No TX/RX
- TX Carrier Only
- H2+ speaker modifications
- Dead Coin Cell Battery
- Factory Defaults
- SD card not recognized by PC with the SD-card over USB selected
- DFU overlay
- Full reset
- SolveBoard
- How to Format SDCard
- Applications
-
Compilation of the firmware
- Compile on WSL with ninja
- How to compile on Windows faster with WSL 2
- Using Docker and Kitematic
- Docker command-line reference
- Using Buddyworks and other CI platforms
- Notes for Buddy.Works (and other CI platforms)
- Using ARM on Debian host
- All in one script for ARM on Debian host
- Compile on Arch based distro (exclude Asahi)
- Dev build versions
- Notes About ccache
- Create a custom map
- Code formatting
- PR process
- Description of the Structure
- Software Dev Guides
- Tools
- Research
- UI Screenshots
- Maintaining
- Creating a prod/stable release (Maintainers only)
- Maintaining rules
- Development States Notes