H) Menu ‐ Calibrate

SK21 edited this page Jul 3, 2024 · 1 revision

Menu – Calibrate

This screen is used to get an accurate pulses/unit value for a product. The idea is to simulate driving at field speed with the meter roller turning at a consistent rpm each time the calibration is done.

Calibration steps:

  1. enter ground speed
  2. set calibration meter speed (rpm)
    • start with Master switch off
    • switch product on with the power button
    • enter initial base rate
    • enter initial Cal Factor
    • press start, RC attempts to adjust flow/rate to target
    • if successful meter speed is locked
    • press stop
  3. set Cal Factor (pulses/unit)
    • start with Master switch off
    • press start, turn Master switch on and let run to get an adequate sample amount
    • press stop and enter measured amount. Cal Factor is calculated.
    • press save to record new values
  4. options to start over
    • if RC is not successful in locking the meter speed adjust initial Cal Factor, ground speed, PWM minimum, PWM maximum or machine metering drive range. Start step 2 again.
    • to redo the meter speed the lock button can be pressed to unlock. RC will then attempt to find a new meter speed when step 2 is redone.
    • to start from a previously saved setting the lock button can be pressed to lock. Then continue with step 3.