#3976 - OS:Coil:Cooling:DX:TwoSpeed - MinOAT **AND** 'Unit Internal S…
Browse files Browse the repository at this point in the history
…tatic Air Pressure'
  • Loading branch information
jmarrec committed May 13, 2020
1 parent 244d569 commit 1c1ed9b
Showing 1 changed file with 25 additions and 12 deletions.
37 changes: 25 additions & 12 deletions resources/model/OpenStudio.idd
Original file line number Diff line number Diff line change
Expand Up @@ -15746,6 +15746,15 @@ OS:Coil:Cooling:DX:TwoSpeed,
\autosizable
\units m3/s
\minimum> 0
N5 , \field Unit Internal Static Air Pressure
\note Enter pressure drop for the unit containing the coil.
\note This value is only used to calculate Energy Efficiency Ratio
\note (EER), Integrated Energy Efficiency Ratio (IEER), and the
\note Standard Rating (Net) Cooling Capacity. This value is not
\note used for modeling the evaporator fan during simulations.
\type real
\units Pa
\minimum> 0.0
A4, \field Air Inlet Node Name
\type object-list
\required-field
Expand Down Expand Up @@ -15789,7 +15798,7 @@ OS:Coil:Cooling:DX:TwoSpeed,
\type object-list
\required-field
\object-list QuadraticCubicCurves
N5, \field Rated Low Speed Total Cooling Capacity
N6, \field Rated Low Speed Total Cooling Capacity
\note gross capacity excluding supply air fan heat
\note rating point: air entering the cooling coil at 26.7 C dry-bulb/19.4 C wet-bulb, and
\note air entering the outdoor condenser coil at 35 C dry-bulb/23.9 C wet-bulb
Expand All @@ -15798,22 +15807,22 @@ OS:Coil:Cooling:DX:TwoSpeed,
\autosizable
\units W
\minimum> 0
N6, \field Rated Low Speed Sensible Heat Ratio
N7, \field Rated Low Speed Sensible Heat Ratio
\note Rated sensible heat ratio (gross sensible capacity/gross total capacity)
\note sensible and total capacities do not include supply fan heat
\type real
\required-field
\autosizable
\minimum 0.5
\maximum 1
N7, \field Rated Low Speed COP
N8, \field Rated Low Speed COP
\note Gross cooling capacity divided by power input to the compressor and outdoor fan,
\note does not include supply fan heat or supply fan electrical energy input
\type real
\units W/W
\minimum> 0
\default 3.0
N8, \field Rated Low Speed Air Flow Rate
N9, \field Rated Low Speed Air Flow Rate
\note Flow rate corresponding to rated total cooling capacity, Rated SHR
\note and Rated COP. Should be between 0.00004027 m3/s and .00006041 m3/s per watt
\note of rated total cooling capacity.
Expand Down Expand Up @@ -15845,37 +15854,41 @@ OS:Coil:Cooling:DX:TwoSpeed,
\default AirCooled
\key AirCooled
\key EvaporativelyCooled
N9, \field High Speed Evaporative Condenser Effectiveness
N10, \field Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
\type real
\default -25.0
\units C
N11, \field High Speed Evaporative Condenser Effectiveness
\type real
\units dimensionless
\minimum 0
\maximum 1
\default 0.9
N10, \field High Speed Evaporative Condenser Air Flow Rate
N12, \field High Speed Evaporative Condenser Air Flow Rate
\note Used to calculate evaporative condenser water use
\type real
\autosizable
\units m3/s
\minimum> 0
N11, \field High Speed Evaporative Condenser Pump Rated Power Consumption
N13, \field High Speed Evaporative Condenser Pump Rated Power Consumption
\note Rated power consumed by the evaporative condenser's water pump at high speed
\type real
\autosizable
\units W
\minimum 0
N12, \field Low Speed Evaporative Condenser Effectiveness
N14, \field Low Speed Evaporative Condenser Effectiveness
\type real
\units dimensionless
\minimum 0
\maximum 1
\default 0.9
N13, \field Low Speed Evaporative Condenser Air Flow Rate
N15, \field Low Speed Evaporative Condenser Air Flow Rate
\note Used to calculate evaporative condenser water use
\type real
\autosizable
\units m3/s
\minimum> 0
N14, \field Low Speed Evaporative Condenser Pump Rated Power Consumption
N16, \field Low Speed Evaporative Condenser Pump Rated Power Consumption
\note Rated power consumed by the evaporative condenser's water pump at low speed
\type real
\autosizable
Expand All @@ -15887,7 +15900,7 @@ OS:Coil:Cooling:DX:TwoSpeed,
A16, \field Condensate Collection Water Storage Tank Name
\type object-list
\object-list WaterStorageTankNames
N15, \field Basin Heater Capacity
N17, \field Basin Heater Capacity
\note This field is only used for Condenser Type = EvaporativelyCooled and for periods
\note when the basin heater is available (field Basin Heater Operating Schedule Name).
\note For this situation, the heater maintains the basin water temperature at the basin heater
Expand All @@ -15897,7 +15910,7 @@ OS:Coil:Cooling:DX:TwoSpeed,
\units W/K
\minimum 0
\default 0.0
N16, \field Basin Heater Setpoint Temperature
N18, \field Basin Heater Setpoint Temperature
\note This field is only used for Condenser Type = EvaporativelyCooled.
\note Enter the outdoor dry-bulb temperature when the basin heater turns on.
\type real
Expand Down