@@ -0,0 +1,255 @@ | ||
"""Tuya pool sensor.""" | ||
|
||
import asyncio | ||
|
||
from zigpy.quirks.v2 import CustomDeviceV2 | ||
from zigpy.quirks.v2.homeassistant import UnitOfTime, UnitOfElectricPotential | ||
from zigpy.quirks.v2.homeassistant.sensor import SensorDeviceClass, SensorStateClass | ||
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass | ||
|
||
import zigpy.types as t | ||
|
||
from zhaquirks.tuya import TUYA_QUERY_DATA, TuyaNewManufCluster, EnchantedDevice | ||
from zhaquirks.tuya.mcu import TuyaMCUCluster, TuyaPowerConfigurationCluster | ||
from zhaquirks.tuya.builder import TuyaQuirkBuilder | ||
|
||
|
||
# Create a quirks v2 of Tuya's EnchantedDevice as we need Tuya spells | ||
EnchantedDevice.__bases__ = (CustomDeviceV2,) | ||
class EnchantedDeviceV2(EnchantedDevice): | ||
"""Updated version of EnchantedDevice based on CustomDeviceV2.""" | ||
tuya_spell_data_query: bool = True # Enable data query spell | ||
|
||
|
||
class TuyaPoolManufCluster(TuyaMCUCluster): | ||
def __init__(self, *args, **kwargs): | ||
"""Init.""" | ||
super().__init__(*args, **kwargs) | ||
self._update_timer_handle = None | ||
self.check_interval = 60 | ||
self.next_refresh_interval = 0 | ||
self._loop = asyncio.get_running_loop() | ||
self.handle_auto_update_check_change() | ||
|
||
def handle_auto_update_cancel(self): | ||
if self._update_timer_handle: | ||
self._update_timer_handle.cancel() | ||
self._update_timer_handle = None | ||
|
||
def handle_auto_update_setup_next_call(self, force_new_interval=False): | ||
tuya_cluster = self.endpoint.device.endpoints[1].in_clusters.get(TuyaMCUCluster.cluster_id, None) | ||
if tuya_cluster and "auto_refresh_interval" in tuya_cluster.attributes_by_name: | ||
interval = tuya_cluster.get("auto_refresh_interval", 0) * 60 | ||
# Check for a change to auto refresh number | ||
if interval != self.next_refresh_interval: | ||
self.handle_auto_update_cancel() | ||
self.next_refresh_interval = interval | ||
force_new_interval = True | ||
|
||
if force_new_interval == True and self.next_refresh_interval > 0: | ||
self.debug("using refresh interval of %d minutes", self.next_refresh_interval) | ||
self._update_timer_handle = self._loop.call_later(self.next_refresh_interval, | ||
self.handle_auto_update_timer_wrapper) | ||
|
||
def handle_auto_update_check_change(self): | ||
self.handle_auto_update_setup_next_call() | ||
self._loop.call_later(self.check_interval, self.handle_auto_update_check_change) | ||
|
||
def handle_auto_update_timer_wrapper(self): | ||
self.create_catching_task(self.handle_auto_update()) | ||
self.handle_auto_update_setup_next_call(force_new_interval=True) | ||
|
||
async def handle_auto_update(self): | ||
tuya_cluster = self.endpoint.device.endpoints[1].in_clusters[TuyaMCUCluster.cluster_id] | ||
self.debug("sending refresh query command") | ||
await tuya_cluster.command(TUYA_QUERY_DATA) | ||
|
||
|
||
( | ||
TuyaQuirkBuilder("_TZE200_v1jqz5cy", "TS0601") | ||
.device_class(EnchantedDeviceV2) | ||
.replaces(TuyaPoolManufCluster) | ||
|
||
.tuya_battery(dp_id=7, power_cfg=TuyaPowerConfigurationCluster, scale=1) | ||
.tuya_temperature(dp_id=2, scale=10) | ||
.tuya_sensor( | ||
dp_id=10, | ||
attribute_name="ph_measured_value", | ||
divisor=100, | ||
type=t.uint16_t, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
device_class=SensorDeviceClass.PH, | ||
translation_key="ph_measured_value", | ||
fallback_name="pH", | ||
) | ||
.tuya_sensor( | ||
dp_id=1, | ||
attribute_name="total_dissolved_solids", | ||
type=t.uint16_t, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
translation_key="total_dissolved_solids", | ||
fallback_name="Total Dissolved Solids", | ||
) | ||
.tuya_sensor( | ||
dp_id=11, | ||
attribute_name="ec_measured_value", | ||
type=t.uint16_t, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
translation_key="ec_measured_value", | ||
fallback_name="Electrical Conductivity", | ||
) | ||
.tuya_sensor( | ||
dp_id=117, | ||
attribute_name="salt_measured_value", | ||
type=t.uint16_t, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
translation_key="salt_measured_value", | ||
fallback_name="Salt Concentration", | ||
) | ||
.tuya_sensor( | ||
dp_id=101, | ||
attribute_name="redox_potential", | ||
type=t.uint16_t, | ||
unit=UnitOfElectricPotential.MILLIVOLT, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
translation_key="redox_potential", | ||
fallback_name="ORP Level", | ||
) | ||
.tuya_sensor( | ||
dp_id=102, | ||
attribute_name="cl_measured_value", | ||
type=t.uint16_t, | ||
state_class=SensorStateClass.MEASUREMENT, | ||
translation_key="cl_measured_value", | ||
fallback_name="Chlorine Concentration", | ||
) | ||
# TODO: 103 enum ? pH Calibration | ||
# TODO: 104 bool ? | ||
# TODO: 105 uint16 | ||
.tuya_number( | ||
dp_id=106, | ||
attribute_name="ph_max_value", | ||
type=t.uint16_t, | ||
multiplier=0.1, | ||
step=0.1, | ||
min_value=0, | ||
max_value=14, | ||
mode="box", | ||
device_class=NumberDeviceClass.PH, | ||
translation_key="ph_max_value", | ||
fallback_name="pH Maximum Value", | ||
) | ||
.tuya_number( | ||
dp_id=107, | ||
attribute_name="ph_min_value", | ||
type=t.uint16_t, | ||
multiplier=0.1, | ||
step=0.1, | ||
min_value=0, | ||
max_value=14, | ||
mode="box", | ||
device_class=NumberDeviceClass.PH, | ||
translation_key="ph_min_value", | ||
fallback_name="pH Minimum Value", | ||
) | ||
.tuya_number( | ||
dp_id=108, | ||
attribute_name="ec_max_value", | ||
type=t.uint16_t, | ||
multiplier=11, | ||
step=1, | ||
min_value=0, | ||
max_value=20000, | ||
mode="box", | ||
translation_key="ec_max_value", | ||
fallback_name="EC Maximum Value", | ||
) | ||
.tuya_number( | ||
dp_id=109, | ||
attribute_name="ec_min_value", | ||
type=t.uint16_t, | ||
multiplier=1, | ||
step=1, | ||
min_value=0, | ||
max_value=20000, | ||
mode="box", | ||
translation_key="ec_min_value", | ||
fallback_name="EC Minimum Value", | ||
) | ||
.tuya_number( | ||
dp_id=110, | ||
attribute_name="orp_max_value", | ||
type=t.uint16_t, | ||
multiplier=1, | ||
step=1, | ||
min_value=-999, | ||
max_value=999, | ||
mode="box", | ||
unit=UnitOfElectricPotential.MILLIVOLT, | ||
device_class=NumberDeviceClass.VOLTAGE, | ||
translation_key="orp_max_value", | ||
fallback_name="ORP Maximum Value", | ||
) | ||
.tuya_number( | ||
dp_id=111, | ||
attribute_name="orp_min_value", | ||
type=t.uint16_t, | ||
multiplier=1, | ||
step=1, | ||
min_value=-999, | ||
max_value=999, | ||
mode="box", | ||
unit=UnitOfElectricPotential.MILLIVOLT, | ||
device_class=NumberDeviceClass.VOLTAGE, | ||
translation_key="orp_min_value", | ||
fallback_name="ORP Minimum Value", | ||
) | ||
.tuya_number( | ||
dp_id=112, | ||
attribute_name="cl_max_value", | ||
type=t.uint16_t, | ||
multiplier=0.1, | ||
step=0.1, | ||
min_value=0, | ||
max_value=4, | ||
mode="box", | ||
translation_key="cl_max_value", | ||
fallback_name="Cl Maximum Value", | ||
) | ||
.tuya_number( | ||
dp_id=113, | ||
attribute_name="cl_min_value", | ||
type=t.uint16_t, | ||
multiplier=0.1, | ||
step=0.1, | ||
min_value=0, | ||
max_value=4, | ||
mode="box", | ||
translation_key="cl_min_value", | ||
fallback_name="Cl Minimum Value", | ||
) | ||
# TODO: 114 uint16_t payload=0 pH Calibration | ||
# TODO: 115 uint16_t payload=0 EC Calibration | ||
# TODO: 116 uint16_t payload=0 ORP Calibration | ||
# TODO: 118 bool payload=0 (false) | ||
# Press button to manually refresh sensor data. | ||
.command_button( | ||
command_name="query_data", | ||
cluster_id=TuyaNewManufCluster.cluster_id, | ||
translation_key="Update", | ||
fallback_name="Update", | ||
) | ||
# Automatic refresh interval in minutes. Set to 0 to disable. | ||
.tuya_number( | ||
dp_id=0x09, | ||
attribute_name="auto_refresh_interval", | ||
type=t.uint16_t, | ||
translation_key="auto_refresh_interval", | ||
fallback_name="Refresh Interval", | ||
unit=UnitOfTime.MINUTES, | ||
step=5, | ||
min_value=0, | ||
max_value=1440, | ||
) | ||
.add_to_registry() | ||
) |