Skip to content

Commit

Permalink
Fix heat mode for legrand outlet
Browse files Browse the repository at this point in the history
  • Loading branch information
piitaya committed Mar 11, 2024
1 parent e4d0663 commit 2de7ca9
Showing 1 changed file with 34 additions and 41 deletions.
75 changes: 34 additions & 41 deletions zhaquirks/legrand/cable_outlet.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,6 @@
"""Module for Legrand Cable Outlet (with pilot wire functionality)."""


from zigpy.profiles import zgp, zha
from zigpy.quirks import CustomCluster, CustomDevice
import zigpy.types as t
Expand All @@ -13,13 +14,7 @@
Scenes,
)
from zigpy.zcl.clusters.homeautomation import ElectricalMeasurement
from zigpy.zcl.foundation import (
BaseAttributeDefs,
BaseCommandDefs,
Direction,
ZCLAttributeDef,
ZCLCommandDef,
)
from zigpy.zcl.foundation import Direction, ZCLCommandDef

from zhaquirks.const import (
DEVICE_TYPE,
Expand All @@ -33,10 +28,7 @@

MANUFACTURER_SPECIFIC_CLUSTER_ID_2 = 0xFC40 # 64576


class DeviceMode(t.enum16):
PILOT_OFF = 0x0100
PILOT_ON = 0x0200
HEAT_MODE_ATTR = 0x00


class LegrandCluster(CustomCluster):
Expand All @@ -45,48 +37,49 @@ class LegrandCluster(CustomCluster):
cluster_id = MANUFACTURER_SPECIFIC_CLUSTER_ID
name = "LegrandCluster"
ep_attribute = "legrand_cluster"

class AttributeDefs(BaseAttributeDefs):
device_mode = ZCLAttributeDef(
id=0x0000,
type=t.data16, # DeviceMode
is_manufacturer_specific=True,
)
led_dark = ZCLAttributeDef(
id=0x0001,
type=t.Bool,
is_manufacturer_specific=True,
)
led_on = ZCLAttributeDef(
id=0x0002,
type=t.Bool,
is_manufacturer_specific=True,
)


class PilotWireMode(t.enum8):
COMFORT = 0x00
COMFORT_MINUS_1 = 0x01
COMFORT_MINUS_2 = 0x02
ECO = 0x03
FROST_PROTECTION = 0x04
OFF = 0x05
attributes = {
0x0000: ("device_mode", t.data16, True),
0x0001: ("led_dark", t.Bool, True),
0x0002: ("led_on", t.Bool, True),
}


class LegrandCableOutletCluster(CustomCluster):
"""Legrand second manufacturer-specific cluster."""

class HeatMode(t.enum8):
COMFORT = 0x00
COMFORT_MINUS_1 = 0x01
COMFORT_MINUS_2 = 0x02
ECO = 0x03
FROST_PROTECTION = 0x04
OFF = 0x05

cluster_id = MANUFACTURER_SPECIFIC_CLUSTER_ID_2
name = "CableOutlet"
ep_attribute = "cable_outlet_cluster"

class ServerCommandDefs(BaseCommandDefs):
set_pilot_wire_mode = ZCLCommandDef(
id=0x00,
schema={"mode": PilotWireMode},
attributes = {HEAT_MODE_ATTR: ("heat_mode", HeatMode, True)}

server_commands = {
HEAT_MODE_ATTR: ZCLCommandDef(
"set_heat_mode",
schema={"mode": HeatMode},
direction=Direction.Client_to_Server,
is_manufacturer_specific=True,
)
}

async def write_attributes(self, attributes, manufacturer=None) -> list:
attrs = {}
for attr, value in attributes.items():
attr_def = self.find_attribute(attr)
attr_id = attr_def.id
if attr_id == HEAT_MODE_ATTR:
await self.set_heat_mode(value, manufacturer=manufacturer)

Check warning on line 79 in zhaquirks/legrand/cable_outlet.py

View check run for this annotation

Codecov / codecov/patch

zhaquirks/legrand/cable_outlet.py#L74-L79

Added lines #L74 - L79 were not covered by tests
else:
attrs[attr] = value
return await super().write_attributes(attrs, manufacturer)

Check warning on line 82 in zhaquirks/legrand/cable_outlet.py

View check run for this annotation

Codecov / codecov/patch

zhaquirks/legrand/cable_outlet.py#L81-L82

Added lines #L81 - L82 were not covered by tests


class Legrand064882CableOutlet(CustomDevice):
Expand Down

0 comments on commit 2de7ca9