# XY-FZ25 & XY-FZ35 Electronic Load Control Program

This program controls "Electronic Load" devices XY-FZ25 and XY-FZ35, sold on different internet sites, mainly from Asia. Instruction manuals for those devices can often be found on the resellers web sites. In folder [**Doc**](https://github.com/yellobyte/ElectronicLoad_Control_XY-FZ35/tree/main/Doc) you find some specs.
This program controls "Electronic Load" devices XY-FZ25 and XY-FZ35, sold on different webshops, mainly from Asia. Most of them provide detailed instruction manuals as well. In folder [**Doc**](https://github.com/yellobyte/ElectronicLoad_Control_XY-FZ35/tree/main/Doc) you find some specs.

![github](https://github.com/yellobyte/ElectronicLoad-Control-XY-FZ35/raw/main/Doc/XY-FZ35a.jpg)

A **programmable electronic load** emulates DC or AC resistance loads required to perform functional tests on batteries, all sorts of power supplies, solar cells, technical equipment, etc. There are many other useful scenarios.
In the simplest case an electronic load just sinks current (absorbes power). The amount of current can be set and the load tries to keep it stable even when the applied voltage changes.

The XY-FZ25 is limited to 4A/25W and the XY-FZ35 to 5A/35W. That doesn't sound much but really is enough for most cases.

I use the combination program + electronic load mainly for battery/accumulator discharge tests and solar power cell tests every now and then.
The XY-FZ25 is limited to 4A/25W and the XY-FZ35 to 5A/35W. That doesn't sound much but really is enough for most cases. I use the combination program + electronic load mainly for battery/accumulator discharge tests and solar power cell tests every now and then.

## :zap: The Control Program

The program "Electronic Load" in folder [**Program**](https://github.com/yellobyte/ElectronicLoad_Control_XY-FZ35/tree/main/Program) does **display** live readings in a chart. Furthermore it can:
- **save** charts to hard drive as **data file** (_.eld_), **bitmap file** (_*.bmp_) or **csv file** (_*.csv_)
- **save** charts as **data file** (_.eld_), **bitmap file** (_*.bmp_) or **csv file** (_*.csv_)
- **print** charts
- **load** previously saved charts (_*.eld_ data files) from hard drive, which gives you the easy ability to compare the final test results of various batteries/accumulators/etc later on
- **load** previously saved charts (_*.eld_ data files), which gives you the easy ability to compare the various test results later on

If you **associate** _*.eld_ files with this program you only need to double click them to see saved charts.

Expand All @@ -33,27 +31,30 @@ The program lets you set various operational parameters. The most important of c

Additionally the load will monitor various definable parameters and trigger an alarm plus turn itself off if required:

- **LVP**...Low Voltage Protection: When the load voltage drops below a set value. This is important for discharge tests in order to protect the accumulator/battery.
- **OAH**...Maximum Discharge Capacity: When the load reaches a defined accumulated discharge capacity (in Ah). This feature too is for protecting the accumulator/battery when doing discharge tests.
- **OHP**...Maximum Discharge Time: When the runtime reaches a set timespan. Important for discharge tests that need to run for hours or even days.
- **LVP**...Low Voltage Protection: When the load voltage drops below a set limit. This is important for discharge tests in order to protect the accumulator/battery.
- **OAH**...Maximum Discharge Capacity: When the load reaches a defined accumulated discharge capacity limit (in Ah). This feature too is for protecting the accumulator/battery when doing discharge tests.
- **OHP**...Maximum Discharge Time: When the runtime reaches a set timespan. Important for tests that need to run for hours or even days.

### :heavy_exclamation_mark: Important
Don't forget to **set the correct hardware version** of the device before controlling it (Settings->Hardware Version->25W/35W) !

## :information_source: Installation
Depending on your Windows architecture copy the 32bit or 64bit version of the executable into a program folder and that's basically it.

In case you get a windows error message trying to run the program (like "mfc140u.dll missing" or similar) depending on your Windows installation you additionally need to install the **Microsoft Visual C++ Redistributables 2019 (x86/x64)** or higher. Those packages are easily available on Microsofts websites, as of today (02/2022) from [here](https://docs.microsoft.com/en-us/cpp/windows/latest-supported-vc-redist?view=msvc-170) for example.
In case you get a windows error message trying to run the program (like "mfc140u.dll missing" or similar) depending on your Windows installation you additionally need to install the **Microsoft Visual C++ Redistributables 2019 (x86/x64)** or higher. Momentarily (02/2022) they are available from [here](https://docs.microsoft.com/en-us/cpp/windows/latest-supported-vc-redist?view=msvc-170).

## :safety_vest: XY-FZ25 & XY-FZ35 Integrated Overload Protection

The devices have different self protection mechanisms built in. If triggered, the device will switch off:
The devices have different self protection mechanisms built in and will turn off when triggered:

- **OVP**...Over Voltage Protection: When the load voltage gets higher than the set OVP voltage limit.
- **OCP**...Over Current Protection: When the load current gets higher than the set OCP current limit.
- **OPP**...Over Power Protection: When the power it absorbes gets greater than the set OPP power limit.

- **OVP**...Over Voltage Protection: When the load voltage is higher then a set value.
- **OCP**...Over Current Protection: When the load current is higher then a set value.
- **OPP**...Over Power Protection: When the load power it absorbes exceeds a set value.
Pressing CTRL+L will retrieve the actual protection limits from the device and show them in the program window (top left section), provided the device is properly connected.

Pressing CTRL+L will retrieve the actual protection limits from the device and show them in the program window (top left), provided the device is properly connected.
**Please note:**
Some alarms (OPP, OAH, OHP) can't be cleared via serial communication. In such cases the On/Off Button on the device itself must be pressed to end the alarm and get the device operational again. Message Boxes will tell you if that's the case.

## :information_source: Wiring

Expand All @@ -63,9 +64,6 @@ This program uses this option to control the devices. For that you only need a c

![github](https://github.com/yellobyte/ElectronicLoad-Control-XY-FZ35/raw/main/Doc/USB-TTL-Wiring.jpg)

**Please note:**
Some alarms (OPP,OAH,OHP) can't be cleared via serial communication. In such cases the On/Off Button on the device itself must be pressed to end the alarm and get the device operational again. Message Boxes will tell you if that's the case.