Sonoff 4CH Pro factory reset #290
Comments
Can you try debugging it via serial? It would be useful to see if it's actually doing something... |
Original comment by Fabien MARCHEWKA (Bitbucket: Fab_33, GitHub: Unknown): Ok after many tests with other firmwares dip switch must be S6:1 K5: All ON and K6: All OFF |
Original comment by Fabien MARCHEWKA (Bitbucket: Fab_33, GitHub: Unknown): So mu latest comment is not clear. With Dip switch config I mention, it works fine except for "One and just One". If you want i can open another issue for this one. |
I have a 4Ch Pro and will test your configuration as soon as I can to document it. |
The issue with the "one and just one" is not specific for the 4CH, any device will show it. Working on it... |
Fixed in the dev branch. Will be released with 1.10.1 |
Released with 1.10.1 |
Actually it shouldn't matter the settings in K6. The device should be in self-locking mode, which means S1 to ON and K5 to ON (all of them). |
Removing milestone: 1.10.1 (automated comment) |
Originally reported by: Fabien MARCHEWKA (Bitbucket: Fab_33, GitHub: Unknown)
My new Sonoff 4CH pro doesn't work. For example moving switch in web UI doesn't have effect. or when switching one channel and switching to another it crash with factory reset (default password fibonacci).