Fix incorrectly focused Combobox.Input
component on page load
#2654
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This PR fixes an odd issue in the
Combobox
where it incorrectly focuses theCombobox.Input
.We have some code that ensures that the selection range of the
Combobox.Input
is correct when syncing values to the input field. However, callingsetSelectionRange
will actually focus theinput
DOM element if it is not focused yet.This PR will only try to set the selection range if the input is the focused element.
Fixes: #2653