Skip to content

Commit

Permalink
[201811] DellEMC S6100 - Port SSD upgrade status checker (#10955)
Browse files Browse the repository at this point in the history
Why I did it
To port DellEMC S6100 SSD upgrade status checker changes from master (based on #7289) to 201811 branch

Handle newer SSD firmware version (S210506G - 3IE devices)
Recover SSD upgrade state if in case ssd_fw_upgrade folder got deleted
  • Loading branch information
ArunSaravananBalachandran authored Jun 15, 2022
1 parent 81ce8b1 commit beb9eac
Showing 1 changed file with 5 additions and 8 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -50,13 +50,13 @@ if [ $SSD_UPGRADE_STATUS1 == "2" ]; then

echo "$0 `date` Upgraded to unknown version after first mp_64 upgrade." >> $SSD_UPGRADE_LOG

elif [ $SSD_UPGRADE_STATUS2 == "2" ];then
elif [ $SSD_MODEL == "3IE3" ] && [ $SSD_UPGRADE_STATUS2 == "2" ];then
rm -rf $SSD_FW_UPGRADE/GPIO7_*
touch $SSD_FW_UPGRADE/GPIO7_error

echo "$0 `date` Upgraded to unknown version after second mp_64 upgrade." >> $SSD_UPGRADE_LOG

elif [ $SSD_FW_VERSION == "s141002g" ] || [ $SSD_FW_VERSION == "s16425cg" ]; then
elif [ $SSD_FW_VERSION == "s210506g" ] || [ $SSD_FW_VERSION == "s16425cg" ]; then
# If SSD Firmware is upgraded
GPIO_STATUS=$(echo "$iSMART_CMD" | grep GPIO | awk '{print $NF}')

Expand All @@ -75,11 +75,11 @@ elif [ $SSD_FW_VERSION == "s141002g" ] || [ $SSD_FW_VERSION == "s16425cg" ]; the
systemctl start --no-block s6100-ssd-monitor.timer

if [ $SSD_MODEL == "3IE" ];then
echo "$0 `date` SSD FW upgraded from S141002C to S141002G in first mp_64." >> $SSD_UPGRADE_LOG
echo "$0 `date` SSD FW upgraded from S141002C to S210506G." >> $SSD_UPGRADE_LOG
else
echo "$0 `date` SSD FW upgraded from S16425c1 to S16425cG in first mp_64." >> $SSD_UPGRADE_LOG
fi
elif [ $SSD_UPGRADE_STATUS2 == "1" ]; then
elif [ $SSD_MODEL == "3IE3" ] && [ $SSD_UPGRADE_STATUS2 == "1" ]; then
rm -rf $SSD_FW_UPGRADE/GPIO7_*
touch $SSD_FW_UPGRADE/GPIO7_low
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
Expand All @@ -104,7 +104,7 @@ else

echo "$0 `date` SSD entered loader mode in first mp_64 upgrade." >> $SSD_UPGRADE_LOG

if [ $SSD_UPGRADE_STATUS2 == "0" ]; then
if [ $SSD_MODEL == "3IE3" ] && [ $SSD_UPGRADE_STATUS2 == "0" ]; then
echo "$0 `date` SSD entered loader mode in first mp_64 and recovered back to older version in second mp_64." >> $SSD_UPGRADE_LOG
fi
fi
Expand All @@ -116,6 +116,3 @@ echo "$0 `date` SMF Register 2 = $SSD_UPGRADE_STATUS2" >> $SSD_UPGRADE_LOG
echo "$SMART_CMD" >> $SSD_UPGRADE_LOG
echo "$iSMART_CMD" >> $SSD_UPGRADE_LOG
sync
# Clearing the upgrade status
io_rd_wr.py --set --val 06 --offset 210; io_rd_wr.py --set --val 09 --offset 211; io_rd_wr.py --set --val ff --offset 213
io_rd_wr.py --set --val 06 --offset 210; io_rd_wr.py --set --val 0A --offset 211; io_rd_wr.py --set --val ff --offset 213

0 comments on commit beb9eac