Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[sonic_platform_test_plan.md]add reboot cause test #451

Merged
merged 1 commit into from
Sep 10, 2019
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
19 changes: 16 additions & 3 deletions doc/pmon/sonic_platform_test_plan.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,7 +6,7 @@
- [1.4 Check xcvrd information in DB](#14-check-xcvrd-information-in-db)
- [1.5 Sequential syncd/swss restart](#15-sequential-syncdswss-restart)
- [1.6 Reload configuration](#16-reload-configuration)
- [1.7 COLD/WARM/FAST reboot](#17-coldwarmfast-reboot)
- [1.7 COLD/WARM/FAST/POWER OFF/WATCHDOG reboot](#17-coldwarmfastpower-offwatchdog-reboot)
- [1.8 Check thermal sensors output using new OPTIC cables](#18-check-thermal-sensors-output-using-new-optic-cables)
- [1.9 Manually plug in and pull out PSU modules](#19-manually-plug-in-and-pull-out-psu-modules)
- [1.10 Manually plug in and pull out PSU power cord](#110-manually-plug-in-and-pull-out-psu-power-cord)
Expand Down Expand Up @@ -354,14 +354,26 @@ New automation required
### Automation
Partly covered by existing automation. New automation required.

## 1.7 COLD/WARM/FAST reboot
## 1.7 COLD/WARM/FAST/POWER OFF/WATCHDOG reboot

### Steps
* Perform cold/warm/fast reboot
* Perform cold/warm/fast/power off/watchdog reboot
* cold/warm/fast reboot
* Make use of commands to reboot the switch
* watchdog reboot
* Make use of new platform api to reboot the switch
* power off reboot
* Make use of PDUs to power on/off DUT.
* Power on/off the DUT for (number of PSUs + 1) * 2 times
* Power on each PSU solely
* Power on all the PSUs simultaneously
* Delay 5 and 15 seconds between powering off and on in each test
* After reboot, check:
* status of services: syncd, swss
* `sudo systemctl status syncd`
* `sudo systemctl status swss`
* reboot cause:
* `show reboot-cause`
* status of hw-management - **Mellanox specific**
* `sudo systemctl status hw-management`
* status of interfaces and port channels
Expand All @@ -375,6 +387,7 @@ Partly covered by existing automation. New automation required.
### Pass/Fail Criteria
* After reboot, status of services, interfaces and transceivers should be normal:
* Services syncd and swss should be active(running)
* Reboot cause should be correct
* Service hw-management should be active(exited) - **Mellanox specific**
* All interface and port-channel status should comply with current topology.
* All transcevers of ports specified in lab connection graph (`ansible/files/lab_connection_graph.xml`) should present.