AIRTERMINAL:SINGLEDUCT:UNCONTROLLED,
zone1DirectAir, !- Name
, !- Availability Schedule Name
zone1 Inlet Node, !- Zone Supply Air Node Name
autosize; !- Maximum Air Flow Rate

AIRTERMINAL:SINGLEDUCT:UNCONTROLLED,
zone2DirectAir, !- Name
, !- Availability Schedule Name
zone2 Inlet Node, !- Zone Supply Air Node Name
autosize; !- Maximum Air Flow Rate

AIRTERMINAL:SINGLEDUCT:UNCONTROLLED,
zone3DirectAir, !- Name
, !- Availability Schedule Name
zone3 Inlet Node, !- Zone Supply Air Node Name
autosize; !- Maximum Air Flow Rate

ZONEHVAC:EQUIPMENTLIST,
zone1 equip list, !- Name
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type
zone1DirectAir, !- Zone Equipment 1 Name
1, !- Zone Equipment 1 Cooling Sequence
1; !- Zone Equipment 1 Heating or NoLoad Sequence

ZONEHVAC:EQUIPMENTLIST,
zone2 equip list, !- Name
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type
zone2DirectAir, !- Zone Equipment 1 Name
1, !- Zone Equipment 1 Cooling Sequence
1; !- Zone Equipment 1 Heating or NoLoad Sequence

ZONEHVAC:EQUIPMENTLIST,
zone3 equip list, !- Name
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type
zone3DirectAir, !- Zone Equipment 1 Name
1, !- Zone Equipment 1 Cooling Sequence
1; !- Zone Equipment 1 Heating or NoLoad Sequence

ZONEHVAC:EQUIPMENTCONNECTIONS,
zone1, !- Zone Name
zone1 equip list, !- Zone Conditioning Equipment List Name
zone1 Inlet Node, !- Zone Air Inlet Node or NodeList Name
, !- Zone Air Exhaust Node or NodeList Name
zone1 Node, !- Zone Air Node Name
zone1 Outlet Node; !- Zone Return Air Node Name

ZONEHVAC:EQUIPMENTCONNECTIONS,
zone2, !- Zone Name
zone2 equip list, !- Zone Conditioning Equipment List Name
zone2 Inlet Node, !- Zone Air Inlet Node or NodeList Name
, !- Zone Air Exhaust Node or NodeList Name
zone2 Node, !- Zone Air Node Name
zone2 Outlet Node; !- Zone Return Air Node Name

ZONEHVAC:EQUIPMENTCONNECTIONS,
zone3, !- Zone Name
zone3 equip list, !- Zone Conditioning Equipment List Name
zone3 Inlet Node, !- Zone Air Inlet Node or NodeList Name
, !- Zone Air Exhaust Node or NodeList Name
zone3 Node, !- Zone Air Node Name
zone3 Outlet Node; !- Zone Return Air Node Name

AIRLOOPHVAC,
a_loop, !- Name
, !- Controller List Name
, !- Availability Manager List Name
0, !- Design Supply Air Flow Rate
a_loop Branches, !- Branch List Name
a_loop Connectors, !- Connector List Name
a_loop Supply Inlet, !- Supply Side Inlet Node Name
a_loop Demand Outlet, !- Demand Side Outlet Node Name
a_loop Demand Inlet, !- Demand Side Inlet Node Names
a_loop Supply Outlet; !- Supply Side Outlet Node Names

AIRLOOPHVAC:ZONESPLITTER,
a_loop Demand Side Splitter, !- Name
a_loop Demand Inlet, !- Inlet Node Name
zone1 Inlet Node, !- Outlet 1 Node Name
zone2 Inlet Node, !- Outlet 2 Node Name
zone3 Inlet Node; !- Outlet 3 Node Name

AIRLOOPHVAC:SUPPLYPATH,
a_loopSupplyPath, !- Name
a_loop Demand Inlet, !- Supply Air Path Inlet Node Name
AirLoopHVAC:ZoneSplitter, !- Component 1 Object Type
a_loop Demand Side Splitter; !- Component 1 Name

AIRLOOPHVAC:ZONEMIXER,
a_loop Demand Side Mixer, !- Name
a_loop Demand Outlet, !- Outlet Node Name
zone1 Outlet Node, !- Inlet 1 Node Name
zone2 Outlet Node, !- Inlet 2 Node Name
zone3 Outlet Node; !- Inlet 3 Node Name

AIRLOOPHVAC:RETURNPATH,
a_loopReturnPath, !- Name
a_loop Demand Outlet, !- Return Air Path Outlet Node Name
AirLoopHVAC:ZoneMixer, !- Component 1 Object Type
a_loop Demand Side Mixer; !- Component 1 Name

BRANCH,
sb0, !- Name
0, !- Maximum Flow Rate
, !- Pressure Drop Curve Name
duct, !- Component 1 Object Type
sb0_duct, !- Component 1 Name
a_loop Supply Inlet, !- Component 1 Inlet Node Name
sb0_duct_outlet, !- Component 1 Outlet Node Name
Bypass; !- Component 1 Branch Control Type

BRANCH,
sb1, !- Name
0, !- Maximum Flow Rate
, !- Pressure Drop Curve Name
duct, !- Component 1 Object Type
sb1_duct, !- Component 1 Name
sb1_duct_inlet, !- Component 1 Inlet Node Name
sb1_duct_outlet, !- Component 1 Outlet Node Name
Bypass; !- Component 1 Branch Control Type

BRANCH,
sb2, !- Name
0, !- Maximum Flow Rate
, !- Pressure Drop Curve Name
duct, !- Component 1 Object Type
sb2_duct, !- Component 1 Name
sb2_duct_inlet, !- Component 1 Inlet Node Name
sb2_duct_outlet, !- Component 1 Outlet Node Name
Bypass; !- Component 1 Branch Control Type

BRANCH,
sb3, !- Name
0, !- Maximum Flow Rate
, !- Pressure Drop Curve Name
duct, !- Component 1 Object Type
sb3_duct, !- Component 1 Name
sb3_duct_inlet, !- Component 1 Inlet Node Name
sb3_duct_outlet, !- Component 1 Outlet Node Name
Bypass; !- Component 1 Branch Control Type

BRANCH,
sb4, !- Name
0, !- Maximum Flow Rate
, !- Pressure Drop Curve Name
duct, !- Component 1 Object Type
sb4_duct, !- Component 1 Name
sb4_duct_inlet, !- Component 1 Inlet Node Name
a_loop Supply Outlet, !- Component 1 Outlet Node Name
Bypass; !- Component 1 Branch Control Type

BRANCHLIST,
a_loop Branches, !- Name
sb0, !- Branch 1 Name
sb1, !- Branch 2 Name
sb2, !- Branch 3 Name
sb3, !- Branch 4 Name
sb4; !- Branch 5 Name

CONNECTOR:SPLITTER,
a_loop_supply_splitter, !- Name
sb0, !- Inlet Branch Name
sb1, !- Outlet Branch 1 Name
sb2, !- Outlet Branch 2 Name
sb3; !- Outlet Branch 3 Name

CONNECTOR:MIXER,
a_loop_supply_mixer, !- Name
sb4, !- Outlet Branch Name
sb1, !- Inlet Branch 1 Name
sb2, !- Inlet Branch 2 Name
sb3; !- Inlet Branch 3 Name

CONNECTORLIST,
a_loop Connectors, !- Name
Connector:Splitter, !- Connector 1 Object Type
a_loop_supply_splitter, !- Connector 1 Name
Connector:Mixer, !- Connector 2 Object Type
a_loop_supply_mixer; !- Connector 2 Name

DUCT,
sb0_duct, !- Name
a_loop Supply Inlet, !- Inlet Node Name
sb0_duct_outlet; !- Outlet Node Name

DUCT,
sb1_duct, !- Name
sb1_duct_inlet, !- Inlet Node Name
sb1_duct_outlet; !- Outlet Node Name

DUCT,
sb2_duct, !- Name
sb2_duct_inlet, !- Inlet Node Name
sb2_duct_outlet; !- Outlet Node Name

DUCT,
sb3_duct, !- Name
sb3_duct_inlet, !- Inlet Node Name
sb3_duct_outlet; !- Outlet Node Name

DUCT,
sb4_duct, !- Name
sb4_duct_inlet, !- Inlet Node Name
a_loop Supply Outlet; !- Outlet Node Name
Binary file modified docs/build/doctrees/HVAC_Tutorial.doctree
Binary file not shown.
Binary file modified docs/build/doctrees/environment.pickle
Binary file not shown.
Binary file modified docs/build/doctrees/eppy_api.doctree
Binary file not shown.
Binary file modified docs/build/doctrees/index.doctree
Binary file not shown.
Binary file modified docs/build/doctrees/installation.doctree
Binary file not shown.
Binary file modified docs/build/doctrees/newfunctions.doctree
Binary file not shown.
Loading

0 comments on commit cd7e2de

Please sign in to comment.