@@ -0,0 +1,205 @@ | ||
|
||
AIRTERMINAL:SINGLEDUCT:UNCONTROLLED, | ||
zone1DirectAir, !- Name | ||
, !- Availability Schedule Name | ||
zone1 Inlet Node, !- Zone Supply Air Node Name | ||
autosize; !- Maximum Air Flow Rate | ||
|
||
AIRTERMINAL:SINGLEDUCT:UNCONTROLLED, | ||
zone2DirectAir, !- Name | ||
, !- Availability Schedule Name | ||
zone2 Inlet Node, !- Zone Supply Air Node Name | ||
autosize; !- Maximum Air Flow Rate | ||
|
||
AIRTERMINAL:SINGLEDUCT:UNCONTROLLED, | ||
zone3DirectAir, !- Name | ||
, !- Availability Schedule Name | ||
zone3 Inlet Node, !- Zone Supply Air Node Name | ||
autosize; !- Maximum Air Flow Rate | ||
|
||
ZONEHVAC:EQUIPMENTLIST, | ||
zone1 equip list, !- Name | ||
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type | ||
zone1DirectAir, !- Zone Equipment 1 Name | ||
1, !- Zone Equipment 1 Cooling Sequence | ||
1; !- Zone Equipment 1 Heating or NoLoad Sequence | ||
|
||
ZONEHVAC:EQUIPMENTLIST, | ||
zone2 equip list, !- Name | ||
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type | ||
zone2DirectAir, !- Zone Equipment 1 Name | ||
1, !- Zone Equipment 1 Cooling Sequence | ||
1; !- Zone Equipment 1 Heating or NoLoad Sequence | ||
|
||
ZONEHVAC:EQUIPMENTLIST, | ||
zone3 equip list, !- Name | ||
AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type | ||
zone3DirectAir, !- Zone Equipment 1 Name | ||
1, !- Zone Equipment 1 Cooling Sequence | ||
1; !- Zone Equipment 1 Heating or NoLoad Sequence | ||
|
||
ZONEHVAC:EQUIPMENTCONNECTIONS, | ||
zone1, !- Zone Name | ||
zone1 equip list, !- Zone Conditioning Equipment List Name | ||
zone1 Inlet Node, !- Zone Air Inlet Node or NodeList Name | ||
, !- Zone Air Exhaust Node or NodeList Name | ||
zone1 Node, !- Zone Air Node Name | ||
zone1 Outlet Node; !- Zone Return Air Node Name | ||
|
||
ZONEHVAC:EQUIPMENTCONNECTIONS, | ||
zone2, !- Zone Name | ||
zone2 equip list, !- Zone Conditioning Equipment List Name | ||
zone2 Inlet Node, !- Zone Air Inlet Node or NodeList Name | ||
, !- Zone Air Exhaust Node or NodeList Name | ||
zone2 Node, !- Zone Air Node Name | ||
zone2 Outlet Node; !- Zone Return Air Node Name | ||
|
||
ZONEHVAC:EQUIPMENTCONNECTIONS, | ||
zone3, !- Zone Name | ||
zone3 equip list, !- Zone Conditioning Equipment List Name | ||
zone3 Inlet Node, !- Zone Air Inlet Node or NodeList Name | ||
, !- Zone Air Exhaust Node or NodeList Name | ||
zone3 Node, !- Zone Air Node Name | ||
zone3 Outlet Node; !- Zone Return Air Node Name | ||
|
||
AIRLOOPHVAC, | ||
a_loop, !- Name | ||
, !- Controller List Name | ||
, !- Availability Manager List Name | ||
0, !- Design Supply Air Flow Rate | ||
a_loop Branches, !- Branch List Name | ||
a_loop Connectors, !- Connector List Name | ||
a_loop Supply Inlet, !- Supply Side Inlet Node Name | ||
a_loop Demand Outlet, !- Demand Side Outlet Node Name | ||
a_loop Demand Inlet, !- Demand Side Inlet Node Names | ||
a_loop Supply Outlet; !- Supply Side Outlet Node Names | ||
|
||
AIRLOOPHVAC:ZONESPLITTER, | ||
a_loop Demand Side Splitter, !- Name | ||
a_loop Demand Inlet, !- Inlet Node Name | ||
zone1 Inlet Node, !- Outlet 1 Node Name | ||
zone2 Inlet Node, !- Outlet 2 Node Name | ||
zone3 Inlet Node; !- Outlet 3 Node Name | ||
|
||
AIRLOOPHVAC:SUPPLYPATH, | ||
a_loopSupplyPath, !- Name | ||
a_loop Demand Inlet, !- Supply Air Path Inlet Node Name | ||
AirLoopHVAC:ZoneSplitter, !- Component 1 Object Type | ||
a_loop Demand Side Splitter; !- Component 1 Name | ||
|
||
AIRLOOPHVAC:ZONEMIXER, | ||
a_loop Demand Side Mixer, !- Name | ||
a_loop Demand Outlet, !- Outlet Node Name | ||
zone1 Outlet Node, !- Inlet 1 Node Name | ||
zone2 Outlet Node, !- Inlet 2 Node Name | ||
zone3 Outlet Node; !- Inlet 3 Node Name | ||
|
||
AIRLOOPHVAC:RETURNPATH, | ||
a_loopReturnPath, !- Name | ||
a_loop Demand Outlet, !- Return Air Path Outlet Node Name | ||
AirLoopHVAC:ZoneMixer, !- Component 1 Object Type | ||
a_loop Demand Side Mixer; !- Component 1 Name | ||
|
||
BRANCH, | ||
sb0, !- Name | ||
0, !- Maximum Flow Rate | ||
, !- Pressure Drop Curve Name | ||
duct, !- Component 1 Object Type | ||
sb0_duct, !- Component 1 Name | ||
a_loop Supply Inlet, !- Component 1 Inlet Node Name | ||
sb0_duct_outlet, !- Component 1 Outlet Node Name | ||
Bypass; !- Component 1 Branch Control Type | ||
|
||
BRANCH, | ||
sb1, !- Name | ||
0, !- Maximum Flow Rate | ||
, !- Pressure Drop Curve Name | ||
duct, !- Component 1 Object Type | ||
sb1_duct, !- Component 1 Name | ||
sb1_duct_inlet, !- Component 1 Inlet Node Name | ||
sb1_duct_outlet, !- Component 1 Outlet Node Name | ||
Bypass; !- Component 1 Branch Control Type | ||
|
||
BRANCH, | ||
sb2, !- Name | ||
0, !- Maximum Flow Rate | ||
, !- Pressure Drop Curve Name | ||
duct, !- Component 1 Object Type | ||
sb2_duct, !- Component 1 Name | ||
sb2_duct_inlet, !- Component 1 Inlet Node Name | ||
sb2_duct_outlet, !- Component 1 Outlet Node Name | ||
Bypass; !- Component 1 Branch Control Type | ||
|
||
BRANCH, | ||
sb3, !- Name | ||
0, !- Maximum Flow Rate | ||
, !- Pressure Drop Curve Name | ||
duct, !- Component 1 Object Type | ||
sb3_duct, !- Component 1 Name | ||
sb3_duct_inlet, !- Component 1 Inlet Node Name | ||
sb3_duct_outlet, !- Component 1 Outlet Node Name | ||
Bypass; !- Component 1 Branch Control Type | ||
|
||
BRANCH, | ||
sb4, !- Name | ||
0, !- Maximum Flow Rate | ||
, !- Pressure Drop Curve Name | ||
duct, !- Component 1 Object Type | ||
sb4_duct, !- Component 1 Name | ||
sb4_duct_inlet, !- Component 1 Inlet Node Name | ||
a_loop Supply Outlet, !- Component 1 Outlet Node Name | ||
Bypass; !- Component 1 Branch Control Type | ||
|
||
BRANCHLIST, | ||
a_loop Branches, !- Name | ||
sb0, !- Branch 1 Name | ||
sb1, !- Branch 2 Name | ||
sb2, !- Branch 3 Name | ||
sb3, !- Branch 4 Name | ||
sb4; !- Branch 5 Name | ||
|
||
CONNECTOR:SPLITTER, | ||
a_loop_supply_splitter, !- Name | ||
sb0, !- Inlet Branch Name | ||
sb1, !- Outlet Branch 1 Name | ||
sb2, !- Outlet Branch 2 Name | ||
sb3; !- Outlet Branch 3 Name | ||
|
||
CONNECTOR:MIXER, | ||
a_loop_supply_mixer, !- Name | ||
sb4, !- Outlet Branch Name | ||
sb1, !- Inlet Branch 1 Name | ||
sb2, !- Inlet Branch 2 Name | ||
sb3; !- Inlet Branch 3 Name | ||
|
||
CONNECTORLIST, | ||
a_loop Connectors, !- Name | ||
Connector:Splitter, !- Connector 1 Object Type | ||
a_loop_supply_splitter, !- Connector 1 Name | ||
Connector:Mixer, !- Connector 2 Object Type | ||
a_loop_supply_mixer; !- Connector 2 Name | ||
|
||
DUCT, | ||
sb0_duct, !- Name | ||
a_loop Supply Inlet, !- Inlet Node Name | ||
sb0_duct_outlet; !- Outlet Node Name | ||
|
||
DUCT, | ||
sb1_duct, !- Name | ||
sb1_duct_inlet, !- Inlet Node Name | ||
sb1_duct_outlet; !- Outlet Node Name | ||
|
||
DUCT, | ||
sb2_duct, !- Name | ||
sb2_duct_inlet, !- Inlet Node Name | ||
sb2_duct_outlet; !- Outlet Node Name | ||
|
||
DUCT, | ||
sb3_duct, !- Name | ||
sb3_duct_inlet, !- Inlet Node Name | ||
sb3_duct_outlet; !- Outlet Node Name | ||
|
||
DUCT, | ||
sb4_duct, !- Name | ||
sb4_duct_inlet, !- Inlet Node Name | ||
a_loop Supply Outlet; !- Outlet Node Name |