Adding Plenum height causes Model running failure.

Current Behavior

After adding the Plenum height, the simulation fails to run.

Expected Behavior

After adding the Plenum height, the simulation should run well.

Steps to Reproduce

  1. Add Plenum height in the Geometry/Editor/Story.
  2. Click Merge with Current OSM.
  3. Click run.
    Following is the video link of this bug.
    https://drive.google.com/file/d/1ktQqWDNuxEvNIjGbz2CheoUnfoL3SCvL/view?usp=sharing

Details

Environment

  • Platform (Operating system, version): Windows 10 Pro (1909) for Workstations
  • Version of OpenStudioApplication: OpenStudio Application 1.0.0
@LouYingli LouYingli added the Triage Issue needs to be assessed and labeled, further information on reported might be needed label Jan 11, 2021
@macumber macumber added component - Geometry Editor severity - Major Bug 💥 and removed Triage Issue needs to be assessed and labeled, further information on reported might be needed labels Jan 17, 2021
@macumber macumber added this to the OpenStudio Application 1.2.0 milestone Jan 17, 2021
@macumber
Copy link
Collaborator

Thanks for the report, this seems like a bad issue.

@macumber
Copy link
Collaborator

I think there are two separate issues here.

First issue:

  1. Create floor plan, merge with model
  2. Set building construction set
  3. Return to floor plan, merge with model
  4. Building construction set is removed

Second issue:

  1. Create floor plan, add plenum height, merge with model
  2. Assign thermal zone to plenum
  3. Return to floor plan, merge with model
  4. Additional thermal zones are created