Skip to content

Commit

Permalink
build: Make configure file parseable on python3
Browse files Browse the repository at this point in the history
Display python3-compatible error message for some systems use python3 as
default.

PR-URL: #9657
Reviewed-By: Ben Noordhuis <[email protected]>
Reviewed-By: Johan Bergström <[email protected]>
Reviewed-By: Gibson Fahnestock <[email protected]>
Reviewed-By: Roman Reiss <[email protected]>
Reviewed-By: Sakthipriyan Vairamani <[email protected]>
  • Loading branch information
kalrover authored and MylesBorins committed Dec 21, 2016
1 parent d03cac8 commit fd31cb3
Showing 1 changed file with 36 additions and 31 deletions.
67 changes: 36 additions & 31 deletions configure
Original file line number Diff line number Diff line change
@@ -1,13 +1,17 @@
#!/usr/bin/env python

import sys
if sys.version_info[0] != 2 or sys.version_info[1] not in (6, 7):
sys.stdout.write("Please use either Python 2.6 or 2.7\n")
sys.exit(1)

import errno
import optparse
import os
import pprint
import re
import shlex
import subprocess
import sys
import shutil
import string

Expand Down Expand Up @@ -488,7 +492,7 @@ def pkg_config(pkg):
shlex.split(pkg_config) + ['--silence-errors', flag, pkg],
stdout=subprocess.PIPE)
val = proc.communicate()[0].strip()
except OSError, e:
except OSError as e:
if e.errno != errno.ENOENT: raise e # Unexpected error.
return (None, None, None) # No pkg-config/pkgconf installed.
retval += (val,)
Expand Down Expand Up @@ -524,12 +528,12 @@ def get_version_helper(cc, regexp):
proc = subprocess.Popen(shlex.split(cc) + ['-v'], stdin=subprocess.PIPE,
stderr=subprocess.PIPE, stdout=subprocess.PIPE)
except OSError:
print '''Node.js configure error: No acceptable C compiler found!
print('''Node.js configure error: No acceptable C compiler found!
Please make sure you have a C compiler installed on your system and/or
consider adjusting the CC environment variable if you installed
it in a non-standard prefix.
'''
''')
sys.exit()

match = re.search(regexp, proc.communicate()[1])
Expand All @@ -555,12 +559,12 @@ def get_gas_version(cc):
stdin=subprocess.PIPE, stderr=subprocess.PIPE,
stdout=subprocess.PIPE)
except OSError:
print '''Node.js configure error: No acceptable C compiler found!
print('''Node.js configure error: No acceptable C compiler found!
Please make sure you have a C compiler installed on your system and/or
consider adjusting the CC environment variable if you installed
it in a non-standard prefix.
'''
''')
sys.exit()

match = re.match(r"GNU assembler version ([2-9]\.[0-9]+)",
Expand Down Expand Up @@ -615,12 +619,12 @@ def cc_macros(cc=None):
stdout=subprocess.PIPE,
stderr=subprocess.PIPE)
except OSError:
print '''Node.js configure error: No acceptable C compiler found!
print('''Node.js configure error: No acceptable C compiler found!
Please make sure you have a C compiler installed on your system and/or
consider adjusting the CC environment variable if you installed
it in a non-standard prefix.
'''
''')
sys.exit()

p.stdin.write('\n')
Expand Down Expand Up @@ -955,7 +959,7 @@ def configure_static(o):

def write(filename, data):
filename = os.path.join(root_dir, filename)
print 'creating ', filename
print('creating %s' % filename)
f = open(filename, 'w+')
f.write(data)

Expand All @@ -975,7 +979,7 @@ def glob_to_var(dir_base, dir_sub, patch_dir):
patchfile = '%s/%s/%s' % (dir_base, patch_dir, file)
if os.path.isfile(patchfile):
srcfile = '%s/%s' % (patch_dir, file)
print 'Using version-specific floating patch %s' % patchfile
print('Using version-specific floating patch %s' % patchfile)
list.append(srcfile)
break
return list
Expand All @@ -990,8 +994,8 @@ def configure_intl(o):
def icu_download(path):
# download ICU, if needed
if not os.access(options.download_path, os.W_OK):
print 'Error: cannot write to desired download path. ' \
'Either create it or verify permissions.'
print('Error: cannot write to desired download path. ' \
'Either create it or verify permissions.')
sys.exit(1)
for icu in icus:
url = icu['url']
Expand All @@ -1002,16 +1006,16 @@ def configure_intl(o):
if nodedownload.candownload(auto_downloads, "icu"):
nodedownload.retrievefile(url, targetfile)
else:
print ' Re-using existing %s' % targetfile
print(' Re-using existing %s' % targetfile)
if os.path.isfile(targetfile):
sys.stdout.write(' Checking file integrity with MD5:\r')
gotmd5 = nodedownload.md5sum(targetfile)
print ' MD5: %s %s' % (gotmd5, targetfile)
print(' MD5: %s %s' % (gotmd5, targetfile))
if (md5 == gotmd5):
return targetfile
else:
print ' Expected: %s *MISMATCH*' % md5
print '\n ** Corrupted ZIP? Delete %s to retry download.\n' % targetfile
print(' Expected: %s *MISMATCH*' % md5)
print('\n ** Corrupted ZIP? Delete %s to retry download.\n' % targetfile)
return None
icu_config = {
'variables': {}
Expand All @@ -1031,7 +1035,7 @@ def configure_intl(o):
with_icu_source = options.with_icu_source
have_icu_path = bool(options.with_icu_path)
if have_icu_path and with_intl != 'none':
print 'Error: Cannot specify both --with-icu-path and --with-intl'
print('Error: Cannot specify both --with-icu-path and --with-intl')
sys.exit(1)
elif have_icu_path:
# Chromium .gyp mode: --with-icu-path
Expand Down Expand Up @@ -1060,8 +1064,8 @@ def configure_intl(o):
o['variables']['v8_enable_i18n_support'] = 1
pkgicu = pkg_config('icu-i18n')
if pkgicu[0] is None:
print 'Error: could not load pkg-config data for "icu-i18n".'
print 'See above errors or the README.md.'
print('Error: could not load pkg-config data for "icu-i18n".')
print('See above errors or the README.md.')
sys.exit(1)
(libs, cflags, libpath) = pkgicu
# libpath provides linker path which may contain spaces
Expand Down Expand Up @@ -1114,17 +1118,17 @@ def configure_intl(o):
# --with-icu-source processing
# now, check that they didn't pass --with-icu-source=deps/icu
elif with_icu_source and os.path.abspath(icu_full_path) == os.path.abspath(with_icu_source):
print 'Ignoring redundant --with-icu-source=%s' % (with_icu_source)
print('Ignoring redundant --with-icu-source=%s' % with_icu_source)
with_icu_source = None
# if with_icu_source is still set, try to use it.
if with_icu_source:
if os.path.isdir(icu_full_path):
print 'Deleting old ICU source: %s' % (icu_full_path)
print('Deleting old ICU source: %s' % icu_full_path)
shutil.rmtree(icu_full_path)
# now, what path was given?
if os.path.isdir(with_icu_source):
# it's a path. Copy it.
print '%s -> %s' % (with_icu_source, icu_full_path)
print('%s -> %s' % (with_icu_source, icu_full_path))
shutil.copytree(with_icu_source, icu_full_path)
else:
# could be file or URL.
Expand All @@ -1148,7 +1152,8 @@ def configure_intl(o):
os.rename(tmp_icu, icu_full_path)
shutil.rmtree(icu_tmp_path)
else:
print ' Error: --with-icu-source=%s did not result in an "icu" dir.' % with_icu_source
print(' Error: --with-icu-source=%s did not result in an "icu" dir.' % \
with_icu_source)
shutil.rmtree(icu_tmp_path)
sys.exit(1)

Expand All @@ -1157,22 +1162,22 @@ def configure_intl(o):
# ICU source dir relative to tools/icu (for .gyp file)
o['variables']['icu_path'] = icu_full_path
if not os.path.isdir(icu_full_path):
print '* ECMA-402 (Intl) support didn\'t find ICU in %s..' % (icu_full_path)
print('* ECMA-402 (Intl) support didn\'t find ICU in %s..' % icu_full_path)
# can we download (or find) a zipfile?
localzip = icu_download(icu_full_path)
if localzip:
nodedownload.unpack(localzip, icu_parent_path)
if not os.path.isdir(icu_full_path):
print ' Cannot build Intl without ICU in %s.' % (icu_full_path)
print ' (Fix, or disable with "--with-intl=none" )'
print(' Cannot build Intl without ICU in %s.' % icu_full_path)
print(' (Fix, or disable with "--with-intl=none" )')
sys.exit(1)
else:
print '* Using ICU in %s' % (icu_full_path)
print('* Using ICU in %s' % icu_full_path)
# Now, what version of ICU is it? We just need the "major", such as 54.
# uvernum.h contains it as a #define.
uvernum_h = os.path.join(icu_full_path, 'source/common/unicode/uvernum.h')
if not os.path.isfile(uvernum_h):
print ' Error: could not load %s - is ICU installed?' % uvernum_h
print(' Error: could not load %s - is ICU installed?' % uvernum_h)
sys.exit(1)
icu_ver_major = None
matchVerExp = r'^\s*#define\s+U_ICU_VERSION_SHORT\s+"([^"]*)".*'
Expand All @@ -1182,7 +1187,7 @@ def configure_intl(o):
if m:
icu_ver_major = m.group(1)
if not icu_ver_major:
print ' Could not read U_ICU_VERSION_SHORT version from %s' % uvernum_h
print(' Could not read U_ICU_VERSION_SHORT version from %s' % uvernum_h)
sys.exit(1)
icu_endianness = sys.byteorder[0];
o['variables']['icu_ver_major'] = icu_ver_major
Expand All @@ -1209,8 +1214,8 @@ def configure_intl(o):
# this is the icudt*.dat file which node will be using (platform endianness)
o['variables']['icu_data_file'] = icu_data_file
if not os.path.isfile(icu_data_path):
print ' Error: ICU prebuilt data file %s does not exist.' % icu_data_path
print ' See the README.md.'
print(' Error: ICU prebuilt data file %s does not exist.' % icu_data_path)
print(' See the README.md.')
# .. and we're not about to build it from .gyp!
sys.exit(1)
# map from variable name to subdirs
Expand Down

0 comments on commit fd31cb3

Please sign in to comment.