Fix #45, use separate dispatcher for messages #49

Merged
merged 1 commit into from
Mar 30, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
1 change: 1 addition & 0 deletions CMakeLists.txt
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,7 @@ project(CFS_HK C)

set(APP_SRC_FILES
fsw/src/hk_app.c
fsw/src/hk_dispatch.c
fsw/src/hk_utils.c
)

Expand Down
114 changes: 57 additions & 57 deletions docs/dox_src/cfs_hk.dox
Original file line number Diff line number Diff line change
Expand Up @@ -53,11 +53,11 @@
<H2> Scope </H2>

This document provides a complete specification for the commands and telemetry associated
with the CFS Housekeeping (HK) application software. The document is intended primarily
for users of the software (operations personal, test engineers, and maintenance personnel).
The last section of the document, the deployment guide section, is intended for mission
developers when deploying and configuring the FM application software for a mission
flight software build environment.
with the CFS Housekeeping (HK) application software. The document is intended primarily
for users of the software (operations personal, test engineers, and maintenance personnel).
The last section of the document, the deployment guide section, is intended for mission
developers when deploying and configuring the FM application software for a mission
flight software build environment.

\ref cfshkversion

Expand Down Expand Up @@ -121,16 +121,16 @@
The HK Application is a passive application and is completely packet driven.
There are no timers used to wake up the application. The housekeeping request
commands are not sent to the system apps by HK. A common system design uses the
Scheduler (SCH) Application to send the housekeeping
Scheduler (SCH) Application to send the housekeeping
requests to the system apps as well as the send-output-message-x command to HK.

A key component that is part of the HK application is the 'copy table'. The copy
A key component that is part of the HK application is the 'copy table'. The copy
table has a configurable number of entries. Each entry specifies a source (via
msgid and offset into the packet), destination (via msgid and offset) and a
msgid and offset into the packet), destination (via msgid and offset) and a
number of bytes to copy.

<H2> HK Design Overview </H2>

The HK Application has a single Software Bus pipe and wakes
up only when a message is received on the pipe (named HK_CMD_PIPE). The
HK_CMD_PIPE receives commands and input messages. If the message received
Expand All @@ -144,10 +144,10 @@
than one area in the same output packet. The number of output packets is also
limited only by the the number of entries in the table. The number of entries in
the table is a platform configuration parameter.
The output messages are sent to the software bus when HK receives the
'Send Output Message x' command. Where 'x' is a parameter in the command that
specifies the message ID of the output message to send. If a piece of data is

The output messages are sent to the software bus when HK receives the
'Send Output Message x' command. Where 'x' is a parameter in the command that
specifies the message ID of the output message to send. If a piece of data is
missing in the output message at the time the 'Send Output Message x' command
is received, the HK app will send a debug event (which is filtered by default)
and increment the 'missing data counter' in telemetry.
Expand All @@ -158,45 +158,45 @@

The operational interface of the HK application consists of two commands, two
tables and a few telemetry points. The following items detail the operational
interface.
interface.

<H2>1. The application version number</H2>

The application version number is displayed in the initialization event and the
no-op event. Both events are 'informational' type and are unfiltered by default.

<H2>2. Loading the copy table</H2>

The copy table is loaded by way of a file. The file must be present when the
application starts up. Otherwise, the app will terminate after initialization.
The location of the file is specified by the platform configuration parameter
named #HK_COPY_TABLE_FILENAME. The value of this define specifies the full
named #HK_COPY_TABLE_FILENAME. The value of this define specifies the full
path as well as the filename.
After initialization, a new copy table may be loaded at any time. The steps to

After initialization, a new copy table may be loaded at any time. The steps to
load a new copy table are:
- Transfer the table file to the on-board file system
- Send the #CFE_TBL_LOAD_CC \copybrief CFE_TBL_LOAD_CC
- Send the #CFE_TBL_VALIDATE_CC \copybrief CFE_TBL_VALIDATE_CC
- Send the #CFE_TBL_ACTIVATE_CC \copybrief CFE_TBL_ACTIVATE_CC

The HK application will clean up the items used for the old table (such as SB
subscriptions) before updating and processing the new table.

<H2>3. Sending the No-op Command</H2>

To verify connectivity with the Housekeeping application, the ground may send an
#HK_NOOP_CC \copybrief HK_NOOP_CC

If the packet length field in the
command is set to the value expected by the HK app, then the command counter will
If the packet length field in the
command is set to the value expected by the HK app, then the command counter will
increment and a #HK_NOOP_CMD_EID event message
will be sent. This no-op event will show the version number of the HK application.

<H2>4. Sending the reset counters command</H2>
The #HK_RESET_CC \copybrief HK_RESET_CC will reset counters in telemetry.

The #HK_RESET_COUNTERS_CC \copybrief HK_RESET_COUNTERS_CC will reset counters in telemetry.

<H2>5. Monitoring the command counter</H2>

The #HK_HkTlm_Payload_t.CmdCounter will increment only
Expand All @@ -208,7 +208,7 @@
b. Unexpected packet length field for #HK_SEND_COMBINED_PKT_MID command
c. Unexpected packet length field for #HK_SEND_HK_MID command
d. Unexpected packet length field for #HK_NOOP_CC command
e. Unexpected packet length field for #HK_RESET_CC command
e. Unexpected packet length field for #HK_RESET_COUNTERS_CC command

<H2>7. Monitoring the 'Combined Packets Sent" counter</H2>

Expand All @@ -229,12 +229,12 @@
The #HK_HkTlm_Payload_t.MissingDataCtr will advance
by one count (at most) and send one event (at most) for each
#HK_SEND_COMBINED_PKT_MID.

The HK app will not zero-out or alter the missing data section(s) in any way.
The missing data values will match the last 'good' section received.

<H2>9. Using the Memory Pool handle to get mempool stats</H2>

The HK memory pool is used to allocate the memory needed to store the output
packets. Each time a new copy table is processed, the memory for the output
packets is dynamically allocated from the memory pool. The memory pool handle is
Expand All @@ -248,30 +248,30 @@
\page cfshkdg CFS Housekeeping Deployment Guide

Follow the general guidelines below for platform deployment of the Housekeeping app.

There are two message IDs that must be included in the CFS Scheduler Table:
#HK_SEND_HK_MID is sent out at the housekeeping request interval. The housekeeping app must send its
housekeeping data to itself like any other app.
#HK_SEND_COMBINED_PKT_MID is sent out at the desired rate for each combined packet. UP to four
combined packets are available.

The HK app can build up to four combined packets based on the definitions supplied in the
HK copy table. The Scheduler Table uses each telemetry IDs (#HK_COMBINED_PKT1_MID ,
HK copy table. The Scheduler Table uses each telemetry IDs (#HK_COMBINED_PKT1_MID ,
#HK_COMBINED_PKT2_MID , #HK_COMBINED_PKT3_MID , and #HK_COMBINED_PKT4_MID ) as a valid parameter
in the #HK_SEND_COMBINED_PKT_MID table entries.

The ES app uses the HK performance ID, #HK_APPMAIN_PERF_ID , to keep track of the performance
of the HK app.
The platform configuration file hk_platform_cfg.h contains parameters that can be adjusted to

The platform configuration file hk_platform_cfg.h contains parameters that can be adjusted to
specific platforms. See \ref cfshkplatformcfg.

See \ref cfshkmissioncfg for mission configuration parameters.
**/

/**
\page cfshktbl CFS Housekeeping Table Definitions

The Housekeeping Application uses two tables. A load-dump table referred to as
the "copy table" and a dump-only table referred to as the "run-time table". Each
table has the same number of entries, defined by the configuration parameter
Expand All @@ -281,12 +281,12 @@
tables were chosen so that checksumming can be executed on the more-static copy
table.

<B>HK Copy Table Validation</B> - The HK copy table currently has an empty validation
call-back function that always returns success. At the time of development,
<B>HK Copy Table Validation</B> - The HK copy table currently has an empty validation
call-back function that always returns success. At the time of development,
a validation process that would apply to all projects was not perceived.

<B>HK Copy Table Entries</B> - Entries follow the concept of:
<I>Copy A bytes from input message B, byte-offset C to output message Y,
<I>Copy A bytes from input message B, byte-offset C to output message Y,
byte-offset Z. </I>

The structure format of a single copy table entry is defined by #hk_copy_table_entry_t.
Expand All @@ -309,7 +309,7 @@
/**
\page cfshkcons CFS Housekeeping Constraints

The Housekeeping Application needs to find a valid table at the location
The Housekeeping Application needs to find a valid table at the location
specified by the configuration parameter #HK_COPY_TABLE_FILENAME in order to
startup. Otherwise the application will send an error event or syslog message
then terminate. See \ref cfshktbl for more detail.
Expand All @@ -323,10 +323,10 @@
\page cfshkfaqs CFS Housekeeping Frequently Asked Questions

<B> (Q)
Does the protocol for collecting telemetry use a single housekeeping request
Does the protocol for collecting telemetry use a single housekeeping request
command for all apps or a unique housekeeping request command for each app?
</B> <BR> <BR> <I>
It is unknown to the HK application because HK does not send the
It is unknown to the HK application because HK does not send the
housekeeping request command(s). These commands are usually sent by the
scheduler. However, each CFS application is capable of receiving a unique
housekeeping request command. The message ID of this command is specified in the
Expand All @@ -336,15 +336,15 @@
housekeeping request commands for each app or using a single command for all
apps. In the latter case, all the defines would be set to the same value.
</I>

<B> (Q)
What is the basic flow of the application?
</B> <BR> <BR> <I>
The HK application uses a common application format. When the app starts,
The HK application uses a common application format. When the app starts,
initialization is performed, then the app enters an infinite loop waiting for
commands from the software bus.
</I>

<B> (Q)
In general, what is done during initialization?
</B> <BR> <BR> <I>
Expand All @@ -356,24 +356,24 @@
variables. If any error is encountered during initialization, the application
will send an event or syslog message, then terminate.
</I>

<B> (Q)
How does the app react if the file to load the copy table (during
How does the app react if the file to load the copy table (during
initialization) is not found?
</B> <BR> <BR> <I>
HK will send an error event or a syslog message, then terminate.
</I>

<B> (Q)
At what frequency is the housekeeping request command sent to the system
At what frequency is the housekeeping request command sent to the system
applications?
</B> <BR> <BR> <I>
The HK application does not send the housekeeping request command to the
system applications. The frequency of the housekeeping request commands is
typically specified in the scheduler table and sent by the scheduler
system applications. The frequency of the housekeeping request commands is
typically specified in the scheduler table and sent by the scheduler
application.
</I>

<B> (Q)
What factor controls the input message timing?
</B> <BR> <BR> <I>
Expand All @@ -382,7 +382,7 @@
command(s). The housekeeping request command(s) are not sent by the HK
application. Rather, it is typically sent by the scheduler application.
</I>

<B> (Q)
What determines the timing of the combined output messages?
</B> <BR> <BR> <I>
Expand All @@ -391,12 +391,12 @@
command periodically. Where 'x' is a parameter in the command that specifies the
message ID of the output message to send.
</I>

<B> (Q)
How is the format of the combined output messages defined?
</B> <BR> <BR> <I>
The output message format is defined by the entries in the copy table. If a
format change to one or more output messages is needed, a new table must be
The output message format is defined by the entries in the copy table. If a
format change to one or more output messages is needed, a new table must be
loaded.
</I>
**/
2 changes: 1 addition & 1 deletion fsw/inc/hk_msg.h
Original file line number Diff line number Diff line change
Expand Up @@ -73,7 +73,7 @@ typedef struct
/**
* \brief No-Operation command packet structure
*
* For command details see #HK_RESET_CC
* For command details see #HK_RESET_COUNTERS_CC
*/
typedef struct
{
Expand Down
2 changes: 1 addition & 1 deletion fsw/inc/hk_msgdefs.h
Original file line number Diff line number Diff line change
Expand Up @@ -86,7 +86,7 @@
* to be designed such that they react to changes in the counter
* values that are reset by this command.
*/
#define HK_RESET_CC 1
#define HK_RESET_COUNTERS_CC 1

/**\}*/

Expand Down