MKS_UPS

mks-viva edited this page Oct 23, 2020 · 2 revisions

How to buy

Video Tutorials

  • If display is LCD12864. It can be referred to LCD12864 UPS

Notice

  • MKS UPS12V can only be used for DC12V power,MKS UPS24V can only be used for DC24V power.

Working process

  • When AC power supply is cut off, the MKS UPS detects it and send signal to motherboard;
  • The power stored in the MKS UPS and PSU continues to supply power to the motherboard;
  • Motherboard detects the power-off signal, stop printing, turn off hotbed and hotend, lift z axis;
  • The power stored in MKS UPS is generally lift z axis 20mm-200mm;
  • When power supply is restored, resume printing through LCD/TFT screen.

Wiring:

  • MKS UPS L N connect to AC power, support AC110 and AC220
  • MKS UPS12V DC12V interface connect to DC12V power, MKS UPS24V DC24V interface connect DC24V power
  • MKS UPS signle out connect to PW_DET

Firmware setting

  • Configuration_adv.h:
    • Enable #define POWER_LOSS_RECOVERY
    • Set #define PLR_ENABLED_DEFAULT true
    • Enable #define BACKUP_POWER_SUPPLY
    • Set #define POWER_LOSS_ZRAISE 20 //mm,can change up to 200
    • Set #define POWER_LOSS_PIN PA2
    • Set #define POWER_LOSS_STATE HIGH

How to use

  • Work with MKS TS35

    • Usage method
      • The external power is cut off directly, the Z axis is improved
      • Power on again, LCD screen choose to resume printing
  • Work with LCD12864

    • Usage method
      • The external power is cut off directly, the Z axis is improved
      • Power on again, LCD screen choose to resume printing