HD bug fix: depth-based axial hydrodynamic coefficients are now set c…
Browse files Browse the repository at this point in the history
…orrectly

Also corrected typos in error messages for member-based hydrodynamic coefficients
  • Loading branch information
luwang00 committed Nov 15, 2024
1 parent 024dbc1 commit 77d483e
Show file tree
Hide file tree
Showing 2 changed files with 7 additions and 7 deletions.
8 changes: 4 additions & 4 deletions modules/hydrodyn/src/HydroDyn_Input.f90
Original file line number Diff line number Diff line change
Expand Up @@ -1911,19 +1911,19 @@ SUBROUTINE HydroDynInput_ProcessInitData( InitInp, Interval, InputFileData, ErrS
RETURN
END IF
IF ( InputFileData%Morison%CoefMembers(I)%MemberAxCa1 < 0 ) THEN
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberCa1 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberAxCa1 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
RETURN
END IF
IF ( InputFileData%Morison%CoefMembers(I)%MemberAxCa2 < 0 ) THEN
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberCa2 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberAxCa2 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
RETURN
END IF
IF ( InputFileData%Morison%CoefMembers(I)%MemberAxCaMG1 < 0 ) THEN
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberCaMG1 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberAxCaMG1 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
RETURN
END IF
IF ( InputFileData%Morison%CoefMembers(I)%MemberAxCaMG2 < 0 ) THEN
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberCaMG2 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
CALL SetErrStat( ErrID_Fatal,'In the member-based hydrodynamic coefficients table, MemberAxCaMG2 must be greater or equal to zero.',ErrStat,ErrMsg,RoutineName)
RETURN
END IF
IF ( InputFileData%Morison%CoefMembers(I)%MemberCb1 < 0 ) THEN
Expand Down
6 changes: 3 additions & 3 deletions modules/hydrodyn/src/Morison.f90
Original file line number Diff line number Diff line change
Expand Up @@ -1111,9 +1111,9 @@ SUBROUTINE SetDepthBasedCoefs( z, tMG, NCoefDpth, CoefDpths, Cd, Ca, Cp, AxCd, A
Cd = CoefDpths(indx1)%DpthCd*(1-s) + CoefDpths(indx2)%DpthCd*s
Ca = CoefDpths(indx1)%DpthCa*(1-s) + CoefDpths(indx2)%DpthCa*s
Cp = CoefDpths(indx1)%DpthCp*(1-s) + CoefDpths(indx2)%DpthCp*s
AxCd = CoefDpths(indx1)%DpthCd*(1-s) + CoefDpths(indx2)%DpthAxCd*s
AxCa = CoefDpths(indx1)%DpthCa*(1-s) + CoefDpths(indx2)%DpthAxCa*s
AxCp = CoefDpths(indx1)%DpthCp*(1-s) + CoefDpths(indx2)%DpthAxCp*s
AxCd = CoefDpths(indx1)%DpthAxCd*(1-s) + CoefDpths(indx2)%DpthAxCd*s
AxCa = CoefDpths(indx1)%DpthAxCa*(1-s) + CoefDpths(indx2)%DpthAxCa*s
AxCp = CoefDpths(indx1)%DpthAxCp*(1-s) + CoefDpths(indx2)%DpthAxCp*s
Cb = CoefDpths(indx1)%DpthCb*(1-s) + CoefDpths(indx2)%DpthCb*s
end if