Problem with first connection to HMS-1600-4t #1749

Open
13 tasks
cypel21 opened this issue Sep 15, 2024 · 18 comments
Open
13 tasks

Problem with first connection to HMS-1600-4t #1749

cypel21 opened this issue Sep 15, 2024 · 18 comments
Assignees
Labels
help wanted Extra attention is needed

Comments

@cypel21
Copy link

cypel21 commented Sep 15, 2024

Hardware

  • ESP8266
  • [ x] ESP32
  • Raspberry Pi

Modelname: ESP32
Retailer URL: https://a.aliexpress.com/_EHoIPTB

CMT2300A

Antenna:

  • circuit board
  • [x ] external antenna (SMA)

Power Stabilization:

  • 100uF Electrolytic Capacitor
    connected between +3.3V and GND (Pin 1 & 2) of the NRF Module
  • Voltage stabilizing motherboard

Version / Git SHA:

Version: 0.8.140 - f1f4481
Github Hash: _______

Build & Flash Method:

  • [X ] AhoyDTU Webinstaller
  • VSCode - Platform IO
  • Arduino
  • ESP Tools

Debugging:

  • USB Serial Log (attached)
  • Setup settings (use our templates ... to be added)

Good morning

This is my first post. Unfortunately I have not been able to connect to my HMS-1600-4t inverters. Yesterday I was able to connect the inverters to the grid.

I added them to the inverters, the radio shows as visible in the settings. Unfortunately I am unable to establish a connection. I have tried to check every frequency and unfortunately with no results.

I put the equipment practically right next to the inverters. The only barrier is the roof tile.

Is there something I can't find?

obraz

0.8.140 - f1f4481

12:29:58.000 W: CMT TX failed, code: 2
12:29:58.045 W: CMT TX failed, code: 2
12:29:58.046 -----
12:29:58.046 W: CMT TX failed, code: 2
12:29:58.099 W: CMT TX failed, code: 2
12:29:58.099 -----
12:29:58.100 W: CMT TX failed, code: 2
12:29:58.119 W: CMT TX failed, code: 2
12:29:58.119 -----
12:29:58.120 W: CMT TX failed, code: 2
12:29:58.284 W: CMT TX failed, code: 2
12:29:58.284 -----
12:29:58.285 I: com loop duration: 285ms
12:29:58.286 -----
12:30:13.000 W: CMT TX failed, code: 2
12:30:13.136 W: CMT TX failed, code: 2
12:30:13.137 -----
12:30:13.138 W: CMT TX failed, code: 2
12:30:13.189 W: CMT TX failed, code: 2
12:30:13.189 -----
12:30:13.190 W: CMT TX failed, code: 2
12:30:13.231 W: CMT TX failed, code: 2
12:30:13.231 -----
12:30:13.232 W: CMT TX failed, code: 2
12:30:13.329 W: CMT TX failed, code: 2
12:30:13.329 -----
12:30:13.330 I: com loop duration: 330ms
12:30:13.331 -----
12:30:43.000 W: CMT TX failed, code: 2
12:30:43.048 W: CMT TX failed, code: 2
12:30:43.049 -----
12:30:43.049 W: CMT TX failed, code: 2
12:30:43.213 W: CMT TX failed, code: 2
12:30:43.213 -----
12:30:43.214 W: CMT TX failed, code: 2
12:30:43.350 W: CMT TX failed, code: 2
12:30:43.350 -----
12:30:43.351 W: CMT TX failed, code: 2
12:30:43.468 W: CMT TX failed, code: 2
12:30:43.468 -----
12:30:43.469 I: com loop duration: 469ms
12:30:43.470 -----
12:30:58.000 W: CMT TX failed, code: 2
12:30:58.114 W: CMT TX failed, code: 2
12:30:58.115 -----
12:30:58.115 W: CMT TX failed, code: 2
12:30:58.208 W: CMT TX failed, code: 2
12:30:58.208 -----
12:30:58.209 W: CMT TX failed, code: 2
12:30:58.252 W: CMT TX failed, code: 2
12:30:58.252 -----
12:30:58.253 W: CMT TX failed, code: 2
12:30:58.372 W: CMT TX failed, code: 2
12:30:58.373 -----
12:30:58.374 I: com loop duration: 374ms
12:30:58.374 -----
12:31:13.000 W: CMT TX failed, code: 2
12:31:13.045 W: CMT TX failed, code: 2
12:31:13.046 -----
12:31:13.046 W: CMT TX failed, code: 2
12:31:13.065 W: CMT TX failed, code: 2
12:31:13.065 -----
12:31:13.066 W: CMT TX failed, code: 2
12:31:13.105 W: CMT TX failed, code: 2
12:31:13.105 -----
12:31:13.106 W: CMT TX failed, code: 2
12:31:13.348 W: CMT TX failed, code: 2
12:31:13.348 -----
12:31:13.349 I: com loop duration: 349ms
12:31:13.350 -----
12:31:28.000 W: CMT TX failed, code: 2
12:31:28.136 W: CMT TX failed, code: 2
12:31:28.137 -----
12:31:28.137 W: CMT TX failed, code: 2
12:31:28.343 W: CMT TX failed, code: 2
12:31:28.343 -----
12:31:28.344 W: CMT TX failed, code: 2
12:31:28.438 W: CMT TX failed, code: 2
12:31:28.438 -----
12:31:28.439 W: CMT TX failed, code: 2
12:31:28.684 W: CMT TX failed, code: 2
12:31:28.685 -----
12:31:28.686 I: com loop duration: 686ms
12:31:28.686 -----
12:31:43.000 W: CMT TX failed, code: 2
12:31:43.053 W: CMT TX failed, code: 2
12:31:43.054 -----
12:31:43.054 W: CMT TX failed, code: 2
12:31:43.218 W: CMT TX failed, code: 2
12:31:43.219 -----
12:31:43.220 W: CMT TX failed, code: 2
12:31:43.355 W: CMT TX failed, code: 2
12:31:43.355 -----
12:31:43.356 W: CMT TX failed, code: 2
12:31:43.518 W: CMT TX failed, code: 2
12:31:43.518 -----
12:31:43.519 I: com loop duration: 519ms
12:31:43.520 -----
12:31:58.000 W: CMT TX failed, code: 2
12:31:58.136 W: CMT TX failed, code: 2
12:31:58.137 -----
12:31:58.137 W: CMT TX failed, code: 2
12:31:58.195 W: CMT TX failed, code: 2
12:31:58.195 -----
12:31:58.196 W: CMT TX failed, code: 2
12:31:58.219 W: CMT TX failed, code: 2
12:31:58.219 -----
12:31:58.220 W: CMT TX failed, code: 2
12:31:58.506 W: CMT TX failed, code: 2
12:31:58.506 -----
12:31:58.507 I: com loop duration: 507ms
12:31:58.508 -----
12:32:13.000 W: CMT TX failed, code: 2
12:32:13.136 W: CMT TX failed, code: 2
12:32:13.137 -----
12:32:13.138 W: CMT TX failed, code: 2
12:32:13.334 W: CMT TX failed, code: 2
12:32:13.334 -----
12:32:13.335 W: CMT TX failed, code: 2
12:32:13.362 W: CMT TX failed, code: 2
12:32:13.362 -----
12:32:13.363 W: CMT TX failed, code: 2
12:32:13.403 W: CMT TX failed, code: 2
12:32:13.403 -----
12:32:13.404 I: com loop duration: 404ms
12:32:13.405 -----
12:32:28.000 W: CMT TX failed, code: 2
12:32:28.136 W: CMT TX failed, code: 2
12:32:28.137 -----
12:32:28.137 W: CMT TX failed, code: 2
12:32:28.423 W: CMT TX failed, code: 2
12:32:28.423 -----
12:32:28.424 W: CMT TX failed, code: 2
12:32:28.560 W: CMT TX failed, code: 2
12:32:28.560 -----
12:32:28.561 W: CMT TX failed, code: 2
12:32:28.790 W: CMT TX failed, code: 2
12:32:28.790 -----
12:32:28.791 I: com loop duration: 791ms
12:32:28.792 -----
12:32:43.001 W: CMT TX failed, code: 2
12:32:43.136 W: CMT TX failed, code: 2
12:32:43.137 -----
12:32:43.137 W: CMT TX failed, code: 2
12:32:43.423 W: CMT TX failed, code: 2
12:32:43.423 -----
12:32:43.424 W: CMT TX failed, code: 2
12:32:43.560 W: CMT TX failed, code: 2
12:32:43.560 -----
12:32:43.561 W: CMT TX failed, code: 2
12:32:43.847 W: CMT TX failed, code: 2
12:32:43.848 -----
12:32:43.849 I: com loop duration: 849ms
12:32:43.849 -----

@TheSCC1992
Copy link

yes, same for me, i went back to the last stable.

@Gubi2023
Copy link

are you shure you have HMS-1600-4t without intern WIFI? this one dont work with Ahoy!

@cypel21
Copy link
Author

cypel21 commented Sep 15, 2024

are you shure you have HMS-1600-4t without intern WIFI? this one dont work with Ahoy!

@Gubi2023 Yes, I am sure

@TheSCC1992 Did it worked? I used also opendtu and nothing

@Gubi2023
Copy link

do you have an entry in marked field?
Screenshot 2024-09-15 145642

@cypel21
Copy link
Author

cypel21 commented Sep 15, 2024

Screenshot_20240915-150325
@Gubi2023 just like yours

@DanielR92
Copy link
Collaborator

Please send us some additionall information.
Self builded Hardware, or buyed?
What is the serial number of your inverter?
What pin-configuration do you have now?

@TheSCC1992
Copy link

are you shure you have HMS-1600-4t without intern WIFI? this one dont work with Ahoy!

@Gubi2023 Yes, I am sure

@TheSCC1992 Did it worked? I used also opendtu and nothing

yes under 0.8.83 it works fine, but when i upgrades to the new stable no communication was available. i waited a whole day but nothing happend.
Self builded Hardware, or buyed? -> self made but with a bught board
What is the serial number of your inverter? 116492230980
What pin-configuration do you have now?
image

@cypel21
Copy link
Author

cypel21 commented Sep 15, 2024

@DanielR92

  1. Self build from ready boards (links in the beginning of this issue)
  2. 1164A00D4A83
    1164A00BECFF
  3. Pin below
    Screenshot_20240915-151722

@lumapu
Copy link
Owner

lumapu commented Sep 21, 2024

W: CMT TX failed, code: 2

for me it looks like having a connection problem to the CMT2300A module. How was it assembled / soldered? I have seen the linked AliExpress item, but how is it connected to the ESP? Are you using jump wires? Has anybody else already tested this baord?

@lumapu lumapu self-assigned this Sep 21, 2024
@lumapu lumapu added the help wanted Extra attention is needed label Sep 21, 2024
@TheSCC1992
Copy link

I don´t think it is a problem with wiring or module. I have got the same problems with my Module. Under 0.83 it is fine, but after updating it does´t work, so there couldn't be a module or wiring problem.

@lumapu
Copy link
Owner

lumapu commented Sep 22, 2024

Ok, understand, thanks for clarifying.
Have you tried to install the newer firmware during night or let it at least installed over night? We have seen communication issues while installing different versions during production of the inverters.

@TheSCC1992
Copy link

i installed now on a new esp32 the 0.8.145 version. after booting I get now my HM Series working, but the HMS are offline, i will check tomorrow, if i get some data.

@MyWebstage
Copy link

Ich habe bei den Großeltern ein Balkonkraftwerk mit dem HMS-1600 am Freitag in Betrieb nehmen wollen. Ich hatte noch eine ältere Version der ahoyDTU installiert und durch die Buchstaben in der Seriennummer festgestellt, dass ich updated muss. Nach dem Update auf 0.8.140 kam keine Verbindung Zustand. Bei mir wird in Version 0.8.140 unter System > CMT2300A > "Interrupt Pin funktioniert = False" angezeigt und ich vermutete einen Hardware-Fehler. Bin also wieder nach Hause.

Als ich das hier gelesen habe, habe ich nun die 0.8.83 installiert. Jetzt steht bei "Interrupt Pin funktioniert = Ja".

Vielleicht hilft das bei der Fehlersuche.

Was anderes zum Thema Limiter:
Wir wissen ja, dass wenn man den WR "normal" auf 800W drosselt, alle 4 Inverter auf fest 200W gedrosselt werden. Ist das Active Power Limiter von Ahoy eine dynamische Regelung der Ausgangsleistung auf 800W? Falls ja - erstmal richtig nice! Aber dann könnte man dieses Feature ein bisschen offensichtlicher präsentieren. Falls nein, gibt es dazu bereits eine Feature-Request?

@TheSCC1992
Copy link

TheSCC1992 commented Sep 23, 2024

also ich habe jetzt die Version 0.8.145 seit gestern laufen, es werden nr die HM WR ausgelesen, alle HMS werden nicht asgelesen, somit liegt es meiner Meinung nach an einem Programmfehler ab Version 0.8.83. Ich werde somit wieder auf die 0.8.83 wechseln. Da ja nicht nur ich sondern auch andere betroffen sind, gehe ich von einen Programmfehler aus.

image
image
` 0.8.145 - 2a99097

webSerial, buffer overflow!
webSerial, buffer overflow!
16:11:29.251 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:29.128 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:29.129 I:
16:11:29.129 I: Iv: 5
16:11:29.129 I: Schuppen oben/ch1/U_DC: 31.600 V
16:11:29.130 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:29.141 I: Schuppen oben/ch1/P_DC: 33.700 W
16:11:29.142 I: Schuppen oben/ch1/YieldDay: 342.000 Wh
16:11:29.142 I: Schuppen oben/ch1/Irradiation: 10.871 %
16:11:29.143 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:29.154 I: Schuppen oben/ch0/U_AC: 243.200 V
16:11:29.155 I: Schuppen oben/ch0/P_AC: 32.000 W
16:11:29.155 I: Schuppen oben/ch0/F_AC: 50.010 Hz
16:11:29.156 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:29.167 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:29.168 I: Schuppen oben/ch0/YieldDay: 342.000 Wh
16:11:29.168 I: Schuppen oben/ch0/P_DC: 33.700 W
16:11:29.180 I: Schuppen oben/ch0/Efficiency: 94.955 %
16:11:29.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:29.181 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:29.181 I:
16:11:29.182 I: Iv: 6
16:11:29.182 I: Balkon/ch1/U_DC: 35.400 V
16:11:29.193 I: Balkon/ch1/I_DC: 0.460 A
16:11:29.194 I: Balkon/ch1/P_DC: 16.200 W
16:11:29.195 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:29.195 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:29.206 I: Balkon/ch1/Irradiation: 4.050 %
16:11:29.207 I: Balkon/ch1/MaxPower: 54.500 W
16:11:29.208 I: Balkon/ch0/U_AC: 242.100 V
16:11:29.208 I: Balkon/ch0/I_AC: 0.060 A
16:11:29.209 I: Balkon/ch0/P_AC: 15.400 W
16:11:29.220 I: Balkon/ch0/F_AC: 50.020 Hz
16:11:29.221 I: Balkon/ch0/PF_AC: 1.000
16:11:29.221 I: Balkon/ch0/Temp: 28.300 °C
16:11:29.222 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:29.223 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:29.234 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:29.234 I: Balkon/ch0/P_DC: 16.200 W
16:11:29.235 I: Balkon/ch0/Efficiency: 95.062 %
16:11:29.236 I: Balkon/ch0/MaxPower: 51.800 W
16:11:29.237 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:11:34.250 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:34.128 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:34.128 I:
16:11:34.128 I: Iv: 5
16:11:34.129 I: Schuppen oben/ch1/U_DC: 31.600 V
16:11:34.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:34.140 I: Schuppen oben/ch1/P_DC: 33.700 W
16:11:34.141 I: Schuppen oben/ch1/YieldDay: 342.000 Wh
16:11:34.142 I: Schuppen oben/ch1/Irradiation: 10.871 %
16:11:34.143 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:34.154 I: Schuppen oben/ch0/U_AC: 243.200 V
16:11:34.154 I: Schuppen oben/ch0/P_AC: 32.000 W
16:11:34.155 I: Schuppen oben/ch0/F_AC: 50.010 Hz
16:11:34.156 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:34.167 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:34.167 I: Schuppen oben/ch0/YieldDay: 342.000 Wh
16:11:34.168 I: Schuppen oben/ch0/P_DC: 33.700 W
16:11:34.179 I: Schuppen oben/ch0/Efficiency: 94.955 %
16:11:34.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:34.181 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:34.181 I:
16:11:34.181 I: Iv: 6
16:11:34.182 I: Balkon/ch1/U_DC: 35.400 V
16:11:34.193 I: Balkon/ch1/I_DC: 0.460 A
16:11:34.193 I: Balkon/ch1/P_DC: 16.200 W
16:11:34.194 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:34.195 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:34.206 I: Balkon/ch1/Irradiation: 4.050 %
16:11:34.207 I: Balkon/ch1/MaxPower: 54.500 W
16:11:34.207 I: Balkon/ch0/U_AC: 242.100 V
16:11:34.208 I: Balkon/ch0/I_AC: 0.060 A
16:11:34.209 I: Balkon/ch0/P_AC: 15.400 W
16:11:34.220 I: Balkon/ch0/F_AC: 50.020 Hz
16:11:34.220 I: Balkon/ch0/PF_AC: 1.000
16:11:34.221 I: Balkon/ch0/Temp: 28.300 °C
16:11:34.222 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:34.222 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:34.233 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:34.234 I: Balkon/ch0/P_DC: 16.200 W
16:11:34.235 I: Balkon/ch0/Efficiency: 95.062 %
16:11:34.236 I: Balkon/ch0/MaxPower: 51.800 W
16:11:34.236 I: Balkon/ch0/MaxTemp: 29.700 °C16:11:38.001 I: (#0) Radio infos: -6 -4 -4 -4 2 | t: 1075, s: 907, f: 36, n: 132 | p: 2
16:11:38.003 I: (#0) TX 27 CH75, 9 ret. | 15 0b 80
16:11:38.305 I: (#0) request timeout: 300ms
16:11:38.306 I: (#0) TX 27 CH75, 9 ret. | 15 0b 80
16:11:38.445 I: (#0) RX 91ms | 27 CH23 | 95 82
16:11:38.446 W: (#0) frame 1 missing: request retransmit (2 attempts left)
16:11:38.447 I: (#0) TX 11 CH75, 9 ret. | 15 75 81
16:11:38.699 W: (#0) frame 1 missing: request retransmit (1 attempts left)
16:11:38.700 I: (#0) TX 11 CH75, 9 ret. | 15 75 81
16:11:38.775 I: (#0) RX 28ms | 27 CH40 | 95 01
16:11:38.776 I: (#0) Payload (30)
16:11:38.777 -----
16:11:38.778 I: (#1) Radio infos: t: 1940, s: 3, f: 0, n: 1937 | p: 10
16:11:38.779 I: (#1) TX 863.25Mhz | 15 02 80
16:11:38.826 W: (#1) frame 1 missing: request retransmit (3 attempts left)
16:11:38.826 I: (#1) TX 863.25Mhz | 15 61 81
16:11:38.857 W: (#1) frame 1 missing: request retransmit (2 attempts left)
16:11:38.857 I: (#1) TX 863.25Mhz | 15 61 81
16:11:38.890 W: (#1) frame 1 missing: request retransmit (1 attempts left)
16:11:38.890 I: (#1) TX 863.25Mhz | 15 61 81
16:11:38.920 W: (#1) frame 1 missing: request retransmit (0 attempts left)
16:11:38.920 I: (#1) TX 863.25Mhz | 15 61 81
16:11:38.959 I: (#1) timeout, no attempts left
16:11:38.959 -----
16:11:38.960 I: (#1) Radio infos: t: 1941, s: 3, f: 0, n: 1938 | p: 10
16:11:38.960 I: (#1) TX 863.25Mhz | 15 0b 80
webSerial, buffer overflow!
webSerial, buffer overflow!
webSerial, buffer overflow!
16:11:39.901 (#6) Radio infos: 3 -4 -4 -4 4 | t: 1065, s: 975, f: 3, n: 87 | p: 2
16:11:39.903 I: (#6) TX 27 CH75, 9 ret. | 15 0b 80
1:39.263 I: (#2) Radio infos: t: 1940, s: 0, f: 0, n: 1940 | p: 10
16:11:39.264 I: (#2) TX 863.25Mhz | 15 05 80
16:11:39.265 W: CMT TX failed, code: 2
16:11:39.300 I: (#2) request timeout: 2ms
16:11:39.300 I: (#2) TX 863.25Mhz | 56 15 02
16:11:39.302 -----
16:11:39.303 I: (#2) Radio infos: t: 1941, s: 0, f: 0, n: 1941 | p: 10
16:11:39.304 I: (#2) TX 863.25Mhz | 15 0b 80
16:11:39.305 W: CMT TX failed, code: 2
16:11:39.355 I: (#2) request timeout: 2ms
16:11:39.355 I: (#2) TX 868.00Mhz | 56 15 02
16:11:39.357 -----
16:11:39.358 I: (#3) Radio infos: t: 1940, s: 0, f: 0, n: 1940 | p: 20
16:11:39.358 I: (#3) TX 863.25Mhz | 15 05 80
16:11:39.359 W: CMT TX failed, code: 2
16:11:39.393 I: (#3) request timeout: 2ms
16:11:39.393 I: (#3) TX 863.25Mhz | 56 15 02
16:11:39.395 -----
16:11:39.396 I: (#3) Radio infos: t: 1941, s: 0, f: 0, n: 1941 | p: 20
16:11:39.397 I: (#3) TX 863.25Mhz | 15 0b 80
16:11:39.397 W: CMT TX failed, code: 2
16:11:39.431 I: (#3) request timeout: 2ms
16:11:39.431 I: (#3) TX 868.00Mhz | 56 15 02
16:11:39.433 -----
16:11:39.434 I: (#4) Radio infos: 4 -1 0 -1 -1 | t: 972, s: 875, f: 50, n: 47 | p: 2
16:11:39.435 I: (#4) TX 11 CH03, 9 ret. | 09 06 09
16:11:39.575 I: (#4) RX 25ms | 16 CH23 | 88 00
16:11:39.576 I: (#4) RX 93ms | 24 CH61 | 89 01
16:11:39.577 I: (#4) TX 11 CH03, 9 ret. | 11 17 00
16:11:39.579 I: (#4) next: (6 attempts left): 0x11
16:11:39.718 I: (#4) RX 25ms | 16 CH23 | 92 00
16:11:39.719 I: (#4) RX 93ms | 24 CH61 | 91 01
16:11:39.721 I: (#4) Payload (MI got all)
16:11:39.721 -----
16:11:39.722 I: (#5) Radio infos: -6 -4 -5 -4 4 | t: 974, s: 687, f: 137, n: 150 | p: 2
16:11:39.723 I: (#5) TX 11 CH75, 15 ret. | 09 e7 09
16:11:39.894 I: (#5) RX 112ms | 24 CH03 | 89 01
16:11:39.895 I: (#5) Payload (MI got all)
16:11:39.896 -----
29.700 °C16:11:40.028 I: (#6) RX 31ms | 27 CH23 | 95 01
16:11:40.029 I: (#6) RX 78ms | 27 CH23 | 95 82
16:11:40.030 I: (#6) Payload (30)
16:11:40.032 -----
16:11:40.033 I: com loop duration: 2033ms
16:11:40.033 -----
webSerial, buffer overflow!
webSerial, buffer overflow!
16:11:44.251 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:44.129 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:44.130 I:
16:11:44.130 I: Iv: 5
16:11:44.130 I: Schuppen oben/ch1/U_DC: 31.700 V
16:11:44.131 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:44.142 I: Schuppen oben/ch1/P_DC: 34.000 W
16:11:44.143 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:11:44.143 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:11:44.144 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:44.155 I: Schuppen oben/ch0/U_AC: 242.500 V
16:11:44.156 I: Schuppen oben/ch0/P_AC: 32.300 W
16:11:44.156 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:11:44.157 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:44.168 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:44.169 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:11:44.170 I: Schuppen oben/ch0/P_DC: 34.000 W
16:11:44.181 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:11:44.181 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:44.182 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:44.182 I:
16:11:44.182 I: Iv: 6
16:11:44.193 I: Balkon/ch1/U_DC: 35.600 V
16:11:44.194 I: Balkon/ch1/I_DC: 0.440 A
16:11:44.195 I: Balkon/ch1/P_DC: 15.700 W
16:11:44.195 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:44.196 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:44.207 I: Balkon/ch1/Irradiation: 3.925 %
16:11:44.208 I: Balkon/ch1/MaxPower: 54.500 W
16:11:44.208 I: Balkon/ch0/U_AC: 241.400 V
16:11:44.209 I: Balkon/ch0/I_AC: 0.060 A
16:11:44.210 I: Balkon/ch0/P_AC: 14.900 W
16:11:44.221 I: Balkon/ch0/F_AC: 50.010 Hz
16:11:44.221 I: Balkon/ch0/PF_AC: 1.000
16:11:44.222 I: Balkon/ch0/Temp: 28.300 °C
16:11:44.223 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:44.223 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:44.235 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:44.236 I: Balkon/ch0/P_DC: 15.700 W
16:11:44.236 I: Balkon/ch0/Efficiency: 94.904 %
16:11:44.237 I: Balkon/ch0/MaxPower: 51.800 W
16:11:44.238 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:11:49.252 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:49.128 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:49.128 I:
16:11:49.128 I: Iv: 5
16:11:49.129 I: Schuppen oben/ch1/U_DC: 31.700 V
16:11:49.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:49.140 I: Schuppen oben/ch1/P_DC: 34.000 W
16:11:49.141 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:11:49.142 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:11:49.143 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:49.154 I: Schuppen oben/ch0/U_AC: 242.500 V
16:11:49.155 I: Schuppen oben/ch0/P_AC: 32.300 W
16:11:49.156 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:11:49.156 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:49.167 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:49.168 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:11:49.169 I: Schuppen oben/ch0/P_DC: 34.000 W
16:11:49.169 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:11:49.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:49.181 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:49.181 I:
16:11:49.182 I: Iv: 6
16:11:49.182 I: Balkon/ch1/U_DC: 35.600 V
16:11:49.193 I: Balkon/ch1/I_DC: 0.440 A
16:11:49.194 I: Balkon/ch1/P_DC: 15.700 W
16:11:49.195 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:49.195 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:49.196 I: Balkon/ch1/Irradiation: 3.925 %
16:11:49.207 I: Balkon/ch1/MaxPower: 54.500 W
16:11:49.208 I: Balkon/ch0/U_AC: 241.400 V
16:11:49.208 I: Balkon/ch0/I_AC: 0.060 A
16:11:49.209 I: Balkon/ch0/P_AC: 14.900 W
16:11:49.210 I: Balkon/ch0/F_AC: 50.010 Hz
16:11:49.221 I: Balkon/ch0/PF_AC: 1.000
16:11:49.221 I: Balkon/ch0/Temp: 28.300 °C
16:11:49.222 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:49.223 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:49.234 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:49.234 I: Balkon/ch0/P_DC: 15.700 W
16:11:49.235 I: Balkon/ch0/Efficiency: 94.904 %
16:11:49.236 I: Balkon/ch0/MaxPower: 51.800 W
16:11:49.236 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:11:54.251 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:54.127 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:54.128 I:
16:11:54.128 I: Iv: 5
16:11:54.129 I: Schuppen oben/ch1/U_DC: 31.700 V
16:11:54.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:54.140 I: Schuppen oben/ch1/P_DC: 34.000 W
16:11:54.141 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:11:54.142 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:11:54.142 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:54.153 I: Schuppen oben/ch0/U_AC: 242.500 V
16:11:54.154 I: Schuppen oben/ch0/P_AC: 32.300 W
16:11:54.155 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:11:54.155 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:54.166 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:54.167 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:11:54.168 I: Schuppen oben/ch0/P_DC: 34.000 W
16:11:54.179 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:11:54.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:54.180 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:54.181 I:
16:11:54.181 I: Iv: 6
16:11:54.181 I: Balkon/ch1/U_DC: 35.600 V
16:11:54.192 I: Balkon/ch1/I_DC: 0.440 A
16:11:54.193 I: Balkon/ch1/P_DC: 15.700 W
16:11:54.194 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:54.195 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:54.206 I: Balkon/ch1/Irradiation: 3.925 %
16:11:54.206 I: Balkon/ch1/MaxPower: 54.500 W
16:11:54.207 I: Balkon/ch0/U_AC: 241.400 V
16:11:54.208 I: Balkon/ch0/I_AC: 0.060 A
16:11:54.208 I: Balkon/ch0/P_AC: 14.900 W
16:11:54.219 I: Balkon/ch0/F_AC: 50.010 Hz
16:11:54.220 I: Balkon/ch0/PF_AC: 1.000
16:11:54.221 I: Balkon/ch0/Temp: 28.300 °C
16:11:54.222 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:54.223 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:54.234 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:54.234 I: Balkon/ch0/P_DC: 15.700 W
16:11:54.235 I: Balkon/ch0/Efficiency: 94.904 %
16:11:54.236 I: Balkon/ch0/MaxPower: 51.800 W
16:11:54.236 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:11:59.251 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:11:59.127 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:11:59.127 I:
16:11:59.128 I: Iv: 5
16:11:59.128 I: Schuppen oben/ch1/U_DC: 31.700 V
16:11:59.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:11:59.140 I: Schuppen oben/ch1/P_DC: 34.000 W
16:11:59.141 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:11:59.141 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:11:59.142 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:11:59.153 I: Schuppen oben/ch0/U_AC: 242.500 V
16:11:59.154 I: Schuppen oben/ch0/P_AC: 32.300 W
16:11:59.154 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:11:59.155 I: Schuppen oben/ch0/Temp: 25.400 °C
16:11:59.166 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:11:59.167 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:11:59.167 I: Schuppen oben/ch0/P_DC: 34.000 W
16:11:59.179 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:11:59.179 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:11:59.180 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:11:59.180 I:
16:11:59.181 I: Iv: 6
16:11:59.181 I: Balkon/ch1/U_DC: 35.600 V
16:11:59.192 I: Balkon/ch1/I_DC: 0.440 A
16:11:59.193 I: Balkon/ch1/P_DC: 15.700 W
16:11:59.194 I: Balkon/ch1/YieldDay: 150.000 Wh
16:11:59.194 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:11:59.205 I: Balkon/ch1/Irradiation: 3.925 %
16:11:59.206 I: Balkon/ch1/MaxPower: 54.500 W
16:11:59.207 I: Balkon/ch0/U_AC: 241.400 V
16:11:59.207 I: Balkon/ch0/I_AC: 0.060 A
16:11:59.208 I: Balkon/ch0/P_AC: 14.900 W
16:11:59.219 I: Balkon/ch0/F_AC: 50.010 Hz
16:11:59.220 I: Balkon/ch0/PF_AC: 1.000
16:11:59.221 I: Balkon/ch0/Temp: 28.300 °C
16:11:59.221 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:11:59.222 I: Balkon/ch0/YieldDay: 150.000 Wh
16:11:59.233 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:11:59.234 I: Balkon/ch0/P_DC: 15.700 W
16:11:59.235 I: Balkon/ch0/Efficiency: 94.904 %
16:11:59.235 I: Balkon/ch0/MaxPower: 51.800 W
16:11:59.236 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:12:04.253 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:12:04.128 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:12:04.128 I:
16:12:04.129 I: Iv: 5
16:12:04.129 I: Schuppen oben/ch1/U_DC: 31.700 V
16:12:04.130 I: Schuppen oben/ch1/I_DC: 1.100 A
16:12:04.141 I: Schuppen oben/ch1/P_DC: 34.000 W
16:12:04.141 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:12:04.142 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:12:04.143 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:12:04.154 I: Schuppen oben/ch0/U_AC: 242.500 V
16:12:04.155 I: Schuppen oben/ch0/P_AC: 32.300 W
16:12:04.155 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:12:04.156 I: Schuppen oben/ch0/Temp: 25.400 °C
16:12:04.167 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:12:04.168 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:12:04.168 I: Schuppen oben/ch0/P_DC: 34.000 W
16:12:04.179 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:12:04.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:12:04.181 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:12:04.181 I:
16:12:04.181 I: Iv: 6
16:12:04.182 I: Balkon/ch1/U_DC: 35.600 V
16:12:04.193 I: Balkon/ch1/I_DC: 0.440 A
16:12:04.194 I: Balkon/ch1/P_DC: 15.700 W
16:12:04.195 I: Balkon/ch1/YieldDay: 150.000 Wh
16:12:04.196 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:12:04.197 I: Balkon/ch1/Irradiation: 3.925 %
16:12:04.208 I: Balkon/ch1/MaxPower: 54.500 W
16:12:04.208 I: Balkon/ch0/U_AC: 241.400 V
16:12:04.209 I: Balkon/ch0/I_AC: 0.060 A
16:12:04.210 I: Balkon/ch0/P_AC: 14.900 W
16:12:04.210 I: Balkon/ch0/F_AC: 50.010 Hz
16:12:04.221 I: Balkon/ch0/PF_AC: 1.000
16:12:04.222 I: Balkon/ch0/Temp: 28.300 °C
16:12:04.223 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:12:04.224 I: Balkon/ch0/YieldDay: 150.000 Wh
16:12:04.225 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:12:04.236 I: Balkon/ch0/P_DC: 15.700 W
16:12:04.236 I: Balkon/ch0/Efficiency: 94.904 %
16:12:04.237 I: Balkon/ch0/MaxPower: 51.800 W
16:12:04.238 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:12:09.250 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:12:09.128 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:12:09.129 I:
16:12:09.129 I: Iv: 5
16:12:09.129 I: Schuppen oben/ch1/U_DC: 31.700 V
16:12:09.130 I: Schuppen oben/ch1/I_DC: 1.100 A
16:12:09.141 I: Schuppen oben/ch1/P_DC: 34.000 W
16:12:09.142 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:12:09.142 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:12:09.143 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:12:09.154 I: Schuppen oben/ch0/U_AC: 242.500 V
16:12:09.155 I: Schuppen oben/ch0/P_AC: 32.300 W
16:12:09.156 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:12:09.156 I: Schuppen oben/ch0/Temp: 25.400 °C
16:12:09.167 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:12:09.168 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:12:09.169 I: Schuppen oben/ch0/P_DC: 34.000 W
16:12:09.180 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:12:09.180 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:12:09.181 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:12:09.182 I:
16:12:09.182 I: Iv: 6
16:12:09.182 I: Balkon/ch1/U_DC: 35.600 V
16:12:09.193 I: Balkon/ch1/I_DC: 0.440 A
16:12:09.194 I: Balkon/ch1/P_DC: 15.700 W
16:12:09.195 I: Balkon/ch1/YieldDay: 150.000 Wh
16:12:09.195 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:12:09.206 I: Balkon/ch1/Irradiation: 3.925 %
16:12:09.207 I: Balkon/ch1/MaxPower: 54.500 W
16:12:09.208 I: Balkon/ch0/U_AC: 241.400 V
16:12:09.208 I: Balkon/ch0/I_AC: 0.060 A
16:12:09.209 I: Balkon/ch0/P_AC: 14.900 W
16:12:09.220 I: Balkon/ch0/F_AC: 50.010 Hz
16:12:09.221 I: Balkon/ch0/PF_AC: 1.000
16:12:09.222 I: Balkon/ch0/Temp: 28.300 °C
16:12:09.222 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:12:09.223 I: Balkon/ch0/YieldDay: 150.000 Wh
16:12:09.234 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:12:09.235 I: Balkon/ch0/P_DC: 15.700 W
16:12:09.235 I: Balkon/ch0/Efficiency: 94.904 %
16:12:09.236 I: Balkon/ch0/MaxPower: 51.800 W
16:12:09.237 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:12:14.251 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:12:14.126 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:12:14.127 I:
16:12:14.127 I: Iv: 5
16:12:14.128 I: Schuppen oben/ch1/U_DC: 31.700 V
16:12:14.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:12:14.140 I: Schuppen oben/ch1/P_DC: 34.000 W
16:12:14.140 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:12:14.141 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:12:14.142 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:12:14.153 I: Schuppen oben/ch0/U_AC: 242.500 V
16:12:14.154 I: Schuppen oben/ch0/P_AC: 32.300 W
16:12:14.154 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:12:14.155 I: Schuppen oben/ch0/Temp: 25.400 °C
16:12:14.166 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:12:14.167 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:12:14.167 I: Schuppen oben/ch0/P_DC: 34.000 W
16:12:14.168 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:12:14.179 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:12:14.180 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:12:14.180 I:
16:12:14.180 I: Iv: 6
16:12:14.181 I: Balkon/ch1/U_DC: 35.600 V
16:12:14.192 I: Balkon/ch1/I_DC: 0.440 A
16:12:14.193 I: Balkon/ch1/P_DC: 15.700 W
16:12:14.193 I: Balkon/ch1/YieldDay: 150.000 Wh
16:12:14.194 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:12:14.195 I: Balkon/ch1/Irradiation: 3.925 %
16:12:14.206 I: Balkon/ch1/MaxPower: 54.500 W
16:12:14.206 I: Balkon/ch0/U_AC: 241.400 V
16:12:14.207 I: Balkon/ch0/I_AC: 0.060 A
16:12:14.208 I: Balkon/ch0/P_AC: 14.900 W
16:12:14.208 I: Balkon/ch0/F_AC: 50.010 Hz
16:12:14.219 I: Balkon/ch0/PF_AC: 1.000
16:12:14.220 I: Balkon/ch0/Temp: 28.300 °C
16:12:14.221 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:12:14.222 I: Balkon/ch0/YieldDay: 150.000 Wh
16:12:14.233 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:12:14.233 I: Balkon/ch0/P_DC: 15.700 W
16:12:14.234 I: Balkon/ch0/Efficiency: 94.904 %
16:12:14.235 I: Balkon/ch0/MaxPower: 51.800 W
16:12:14.236 I: Balkon/ch0/MaxTemp: 29.700 °CwebSerial, buffer overflow!
webSerial, buffer overflow!
16:12:19.252 I:
Schuppen unten/ch0/MaxPower: 139.900 W
16:12:19.127 I: Schuppen unten/ch0/MaxTemp: 28.300 °C
16:12:19.127 I:
16:12:19.127 I: Iv: 5
16:12:19.128 I: Schuppen oben/ch1/U_DC: 31.700 V
16:12:19.129 I: Schuppen oben/ch1/I_DC: 1.100 A
16:12:19.140 I: Schuppen oben/ch1/P_DC: 34.000 W
16:12:19.141 I: Schuppen oben/ch1/YieldDay: 343.000 Wh
16:12:19.141 I: Schuppen oben/ch1/Irradiation: 10.968 %
16:12:19.142 I: Schuppen oben/ch1/MaxPower: 73.700 W
16:12:19.153 I: Schuppen oben/ch0/U_AC: 242.500 V
16:12:19.154 I: Schuppen oben/ch0/P_AC: 32.300 W
16:12:19.154 I: Schuppen oben/ch0/F_AC: 50.000 Hz
16:12:19.155 I: Schuppen oben/ch0/Temp: 25.400 °C
16:12:19.166 I: Schuppen oben/ch0/ALARM_MES_ID: 1.000
16:12:19.167 I: Schuppen oben/ch0/YieldDay: 343.000 Wh
16:12:19.167 I: Schuppen oben/ch0/P_DC: 34.000 W
16:12:19.178 I: Schuppen oben/ch0/Efficiency: 95.000 %
16:12:19.179 I: Schuppen oben/ch0/MaxPower: 70.000 W
16:12:19.180 I: Schuppen oben/ch0/MaxTemp: 27.400 °C
16:12:19.181 I:
16:12:19.181 I: Iv: 6
16:12:19.181 I: Balkon/ch1/U_DC: 35.600 V
16:12:19.192 I: Balkon/ch1/I_DC: 0.440 A
16:12:19.193 I: Balkon/ch1/P_DC: 15.700 W
16:12:19.194 I: Balkon/ch1/YieldDay: 150.000 Wh
16:12:19.194 I: Balkon/ch1/YieldTotal: 245.846 kWh
16:12:19.195 I: Balkon/ch1/Irradiation: 3.925 %
16:12:19.206 I: Balkon/ch1/MaxPower: 54.500 W
16:12:19.207 I: Balkon/ch0/U_AC: 241.400 V
16:12:19.207 I: Balkon/ch0/I_AC: 0.060 A
16:12:19.208 I: Balkon/ch0/P_AC: 14.900 W
16:12:19.209 I: Balkon/ch0/F_AC: 50.010 Hz
16:12:19.220 I: Balkon/ch0/PF_AC: 1.000
16:12:19.220 I: Balkon/ch0/Temp: 28.300 °C
16:12:19.221 I: Balkon/ch0/ALARM_MES_ID: 1.000
16:12:19.222 I: Balkon/ch0/YieldDay: 150.000 Wh
16:12:19.233 I: Balkon/ch0/YieldTotal: 245.846 kWh
16:12:19.234 I: Balkon/ch0/P_DC: 15.700 W
16:12:19.234 I: Balkon/ch0/Efficiency: 94.904 %
16:12:19.235 I: Balkon/ch0/MaxPower: 51.800 W
16:12:19.236 I: Balkon/ch0/MaxTemp: 29.700 °C `

@MyWebstage
Copy link

So ich muss zurück rudern. Auch mit Version 0.8.140 bekomme ich nun Daten und der Interrupt-Pin ist auch wieder grün. Ich habe die Frequenz auf 865MHz geändert und ca. 20 Minuten gewartet.

Elko mit 100yF ist an den Spannungspins des CMT2300A.

Super, also die Software tut. 👍

@TheSCC1992
Copy link

so habe nun einen neuen CMT2300A bestellt, mal schauen ob das läuft

@lumapu
Copy link
Owner

lumapu commented Sep 23, 2024

ich sage es nochmal: installiert die neue Version am Abend / Nacht und wartet bis zum nächsten Morgen, dann wird alles wie gewohnt funktionieren.

lumapu added a commit that referenced this issue Oct 3, 2024
* add button for CMT inverters to catch them independend on which frequency they were before #1749
@mortiii
Copy link

mortiii commented Nov 17, 2024

ich habe ein ähnliches Problem. CMT2300a ESP32 (Set von Blinky Parts) HMS-1600-4T. Die Verbindung zum CMT2300a ist in Ordnung. Ich habe mehrere Builds ausprobiert. 0.8.83 (Buchstaben in Seriennummer nicht erlaubt) / 0.8.140 / 0.8.152. Leider wird nie eine Verbindung zum Wechselrichter aufgebaut. Wenn ich bei 0.8.152 auf Wechselrichter suchen klicke kommt folgende Meldung: Fehler:ERR_INDEX.

Die Seriennummer habe ich mehrmals geprüft.
Das HMS-1600-4T hat kein WLAN Modul eingebaut.

bitte um Hilfe.