Notifications
You must be signed in to change notification settings - Fork 245
fix: signal handling #227
fix: signal handling #227
Changes from all commits
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -10,7 +10,7 @@ function crossEnv(args, options = {}) { | |
const [envSetters, command, commandArgs] = parseCommand(args) | ||
const env = getEnvVars(envSetters) | ||
if (command) { | ||
const proc = spawn( | ||
let child = spawn( | ||
// run `path.normalize` for command(on windows) | ||
commandConvert(command, env, true), | ||
// by default normalize is `false`, so not run for cmd args | ||
|
@@ -21,20 +21,59 @@ function crossEnv(args, options = {}) { | |
env, | ||
}, | ||
) | ||
process.on('SIGTERM', () => proc.kill('SIGTERM')) | ||
process.on('SIGINT', () => proc.kill('SIGINT')) | ||
process.on('SIGBREAK', () => proc.kill('SIGBREAK')) | ||
process.on('SIGHUP', () => proc.kill('SIGHUP')) | ||
proc.on('exit', (code, signal) => { | ||
let crossEnvExitCode = code | ||
// exit code could be null when OS kills the process(out of memory, etc) or due to node handling it | ||
// but if the signal is SIGINT the user exited the process so we want exit code 0 | ||
if (crossEnvExitCode === null) { | ||
crossEnvExitCode = signal === 'SIGINT' ? 0 : 1 | ||
|
||
// See https://github.com/jtlapp/node-cleanup | ||
// | ||
// > When you hit Ctrl-C, you send a SIGINT signal to each process in the | ||
// > current process group. A process group is set of processes that are | ||
// > all supposed to end together as a group instead of persisting | ||
// > independently. However, some programs, such as Emacs, intercept and | ||
// > repurpose SIGINT so that it does not end the process. In such cases, | ||
// > SIGINT should not end any processes of the group. | ||
// | ||
// Delegate decision to terminate to child process, if the child exits on | ||
// SIGINT then the `child.on('exit')` callback will be invoked, re-raising | ||
// the signal to the parent process | ||
const delegateSignalToChild = signal => () => { | ||
// SIGINT is sent to all processes in group, no need to delegate. | ||
if (child && signal !== 'SIGINT') { | ||
process.kill(child.pid, signal) | ||
} | ||
} | ||
|
||
const sigtermHandler = delegateSignalToChild('SIGTERM') | ||
const sigintHandler = delegateSignalToChild('SIGINT') | ||
const sigbreakHandler = delegateSignalToChild('SIGBREAK') | ||
const sighupHandler = delegateSignalToChild('SIGHUP') | ||
const sigquitHandler = delegateSignalToChild('SIGQUIT') | ||
|
||
process.on('SIGTERM', sigtermHandler) | ||
process.on('SIGINT', sigintHandler) | ||
process.on('SIGBREAK', sigbreakHandler) | ||
process.on('SIGHUP', sighupHandler) | ||
process.on('SIGQUIT', sigquitHandler) | ||
|
||
child.on('exit', (exitCode, signal) => { | ||
// Child has decided to exit. | ||
child = null | ||
process.removeListener('SIGTERM', sigtermHandler) | ||
process.removeListener('SIGINT', sigintHandler) | ||
process.removeListener('SIGBREAK', sigbreakHandler) | ||
process.removeListener('SIGHUP', sighupHandler) | ||
process.removeListener('SIGQUIT', sigquitHandler) | ||
|
||
if (exitCode !== null) { | ||
// Calling process.exit is not necessary most of the time, | ||
// see https://nodejs.org/api/process.html#process_process_exit_code | ||
process.exitCode = exitCode | ||
} | ||
if (signal !== null) { | ||
// Pass through child's signal to parent. | ||
// SIGINT should not be transformed into a 0 exit code | ||
process.kill(process.pid, signal) | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Do I understand correctly that the code does the following?
The One case that looks a bit suspicious: if I kill the parent process explicitly, with There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Yes your understanding is correct for the example using For the example of SIGINT, all I can say is the documentation I found indicates this is what happens on Unix systems. I haven't tested this on that platform. If you can find a definitive guide to signal handling I"m happy to adjust the code. On Windows there is no such thing as signals, they are emulated by Node Signal Events Did you try the |
||
} | ||
process.exit(crossEnvExitCode) //eslint-disable-line no-process-exit | ||
}) | ||
return proc | ||
return child | ||
} | ||
return null | ||
} | ||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
The signal event receives the signal name as the argument. That means you don't need to create a special handler for each signal:
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Sure. I was following other examples around the place to get the correct handling working.
As the original code created inline arrow functions to handle the individual events I just kept a similar code flow.
I wasn't sure whether the listeners would vary or be removed independently so went with the more verbose style.