The number of temperature sensors that read the temperature was reduc… #394
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
…ed from five to three.
PR描述:
Fixed the problem that the value read back by the sip board temperature sensor was incorrect.
详细描述:
The power supply pins of the first two temperature sensors in the sip chip are floating, so instead of reading the average value of five temperature sensors in the original drive, read the average value of three temperature sensors.
关联issue:
#393
fix #X