The number of temperature sensors that read the temperature was reduc… #394

Merged
merged 1 commit into from
Nov 22, 2022

Conversation

mara-sys
Copy link
Contributor

@mara-sys mara-sys commented Nov 21, 2022

…ed from five to three.

PR描述:

Fixed the problem that the value read back by the sip board temperature sensor was incorrect.

详细描述:

The power supply pins of the first two temperature sensors in the sip chip are floating, so instead of reading the average value of five temperature sensors in the original drive, read the average value of three temperature sensors.

关联issue:

#393
fix #X

@mara-sys mara-sys added the bug Something isn't working label Nov 21, 2022
@mara-sys mara-sys added this to the v1.9 milestone Nov 21, 2022
@mara-sys mara-sys self-assigned this Nov 21, 2022
@zhangxiaojingCAN zhangxiaojingCAN merged commit fe7e59c into kendryte:dev Nov 22, 2022