This is a very, very beta interface for Bosch-Siemens Home Connect devices through their local network connection. Unlike most IoT devices that have a reputation for very bad security, BSG seem to have done a decent job of designing their system, especially since they allow a no-cloud local control configuration. The protocols seem sound, use well tested cryptographic libraries (TLS PSK with modern ciphres) or well understood primitives (AES-CBC with HMAC), and should prevent most any random attacker on your network from being able to take over your appliances to mine cryptocurrency.
WARNING: This tool not ready for prime time and is still beta!
To avoid running into issues later with your default python installs, it's recommended to use a py virtual env for doing this. Go to your desired test directory, and:
python3 -m venv venv
source venv/bin/activate
git clone https://github.com/osresearch/hcpy
cd hcpy
pip3 install -r requirements.txt
Install the Python dependencies; the sslpsk
one is a little weird
and we might need to revisit it later.
Installing sslpsk
needs some extra steps:
- The openssl package installed via brew:
brew install openssl
, and - Install
saslpsk
separately with flags:LDFLAGS="-L$(brew --prefix openssl)/lib" CFLAGS="-I$(brew --prefix openssl)/include" pip3 install sslpsk
- Rest of the requirements should be fine with
pip3 install -r requirements.txt
hc-login $USERNAME $PASSWORD > config.json
The hc-login
script perfoms the OAuth process to login to your
Home Connect account with your usename and password. It
receives a bearer token that can then be used to retrieves
a list of all the connected devices, their authentication
and encryption keys, and XML files that describe all of the
features and options.
This only needs to be done once or when you add new devices; the resulting configuration JSON file should be sufficient to connect to the devices on your local network, assuming that your mDNS or DNS server resolves the names correctly.
hc2mqtt config.json
This tool will establish websockets to the local devices and transform their messages into MQTT JSON messages. The exact format is likely to change; it is currently a thin translation layer over the XML retrieved from cloud servers during the initial configuration.
The dishwasher has a local HTTPS port open, although attempting to connect to
the HTTPS port with curl
results in a cryptic protocol error
due to the non-standard cipher selection, ECDHE-PSK-CHACHA20-POLY1305
.
PSK also requires that both sides agree on a symetric key,
so a special hacked version of sslpsk
is used to establish the
connection and then hand control to the Python websock-client
library.
Example message published to homeconnect/dishwasher
:
{
"state": "Run",
"door": "Closed",
"remaining": "2:49",
"power": true,
"lowwaterpressure": false,
"aquastop": false,
"error": false,
"remainingseconds": 10140
}
Full state information
{
'AllowBackendConnection': False,
'BackendConnected': False,
'RemoteControlLevel': 'ManualRemoteStart',
'SoftwareUpdateAvailable': 'Off',
'ConfirmPermanentRemoteStart': 'Off',
'ActiveProgram': 0,
'SelectedProgram': 8192,
'RemoteControlStartAllowed': False,
'520': '2022-02-21T16:48:54',
'RemoteControlActive': True,
'AquaStopOccured': 'Off',
'DoorState': 'Open',
'PowerState': 'Off',
'ProgramFinished': 'Off',
'ProgramProgress': 100,
'LowWaterPressure': 'Off',
'RemainingProgramTime': 0,
'ProgramAborted': 'Off',
'547': False,
'RemainingProgramTimeIsEstimated': True,
'OperationState': 'Inactive',
'StartInRelative': 0,
'EnergyForecast': 82,
'WaterForecast': 70,
'ConnectLocalWiFi': 'Off',
'SoftwareUpdateTransactionID': 0,
'SoftwareDownloadAvailable': 'Off',
'SoftwareUpdateSuccessful': 'Off',
'ProgramPhase': 'Drying',
'SilenceOnDemandRemainingTime': 0,
'EcoDryActive': False,
'RinseAid': 'R04',
'SensitivityTurbidity': 'Standard',
'ExtraDry': False,
'HotWater': 'ColdWater',
'TimeLight': 'On',
'EcoAsDefault': 'LastProgram',
'SoundLevelSignal': 'Off',
'SoundLevelKey': 'Medium',
'WaterHardness': 'H04',
'DryingAssistantAllPrograms': 'AllPrograms',
'SilenceOnDemandDefaultTime': 1800,
'SpeedOnDemand': False,
'InternalError': 'Off',
'CheckFilterSystem': 'Off',
'DrainingNotPossible': 'Off',
'DrainPumpBlocked': 'Off',
'WaterheaterCalcified': 'Off',
'LowVoltage': 'Off',
'SaltLack': 'Off',
'RinseAidLack': 'Off',
'SaltNearlyEmpty': 'Off',
'RinseAidNearlyEmpty': 'Off',
'MachineCareReminder': 'Off',
'5121': False,
'HalfLoad': False,
'IntensivZone': False,
'VarioSpeedPlus': False,
'5131': False,
'5134': True,
'SilenceOnDemand': False
}
The clothes washer has a local HTTP port that also responds to websocket
traffic, although the contents of the frames are AES-CBC encrypted with a key
derived from HMAC(PSK,"ENC")
and authenticated with SHA256-HMAC using another
key derived from HMAC(PSK,"MAC")
. The encrypted messages are send as
binary data over the websocket (type 0x82).
Example message published to homeconnect/washer
:
{
"state": "Ready",
"door": "Closed",
"remaining": "3:48",
"power": true,
"lowwaterpressure": false,
"aquastop": false,
"error": false,
"remainingseconds": 13680
}
Full state information
{
'BackendConnected': False,
'CustomerEnergyManagerPaired': False,
'CustomerServiceConnectionAllowed': False,
'DoorState': 'Open',
'FlexStart': 'Disabled',
'LocalControlActive': False,
'OperationState': 'Ready',
'RemoteControlActive': True,
'RemoteControlStartAllowed': False,
'WiFiSignalStrength': -50,
'LoadInformation': 0,
'AquaStopOccured': 'Off',
'CustomerServiceRequest': 'Off',
'LowWaterPressure': 'Off',
'ProgramFinished': 'Off',
'SoftwareUpdateAvailable': 'Off',
'WaterLevelTooHigh': 'Off',
'DoorNotLockable': 'Off',
'DoorNotUnlockable': 'Off',
'DoorOpen': 'Off',
'FatalErrorOccured': 'Off',
'FoamDetection': 'Off',
'DrumCleanReminder': 'Off',
'PumpError': 'Off',
'ReleaseRinseHoldPending': 'Off',
'EnergyForecast': 20,
'EstimatedTotalProgramTime': 13680,
'FinishInRelative': 13680,
'FlexFinishInRelative': 0,
'ProgramProgress': 0,
'RemainingProgramTime': 13680,
'RemainingProgramTimeIsEstimated': True,
'WaterForecast': 40,
'LoadRecommendation': 10000,
'ProcessPhase': 4,
'ReferToProgram': 0,
'LessIroning': False,
'Prewash': False,
'RinseHold': False,
'RinsePlus': 0,
'SilentWash': False,
'Soak': False,
'SpeedPerfect': False,
'SpinSpeed': 160,
'Stains': 0,
'Temperature': 254,
'WaterPlus': False,
'AllowBackendConnection': False,
'AllowEnergyManagement': False,
'AllowFlexStart': False,
'ChildLock': False,
'Language': 'En',
'PowerState': 'On',
'EndSignalVolume': 'Medium',
'KeySignalVolume': 'Loud',
'EnableDrumCleanReminder': True,
'ActiveProgram': 0,
'SelectedProgram': 28718
}
The coffee machine needs a better mapping to MQTT messages.
Full state information
{
'LastSelectedBeverage': 8217,
'LocalControlActive': False,
'PowerSupplyError': 'Off',
'DripTrayNotInserted': 'Off',
'DripTrayFull': 'Off',
'WaterFilterShouldBeChanged': 'Off',
'WaterTankEmpty': 'Off',
'WaterTankNearlyEmpty': 'Off',
'BrewingUnitIsMissing': 'Off',
'SelectedProgram': 0,
'MacchiatoPause': '5Sec',
'ActiveProgram': 0,
'BeverageCountdownWaterfilter': 48,
'BeverageCountdownCalcNClean': 153,
'RemoteControlStartAllowed': True,
'EmptyDripTray': 'Off',
'BeverageCountdownDescaling': 153,
'EmptyDripTrayRemoveContainer': 'Off',
'BeverageCounterRistrettoEspresso': 177,
'AllowBackendConnection': True,
'BeverageCounterHotWater': 37351,
'RemindForMilkAfter': 'Off',
'BeverageCounterFrothyMilk': 22,
'BeverageCounterCoffeeAndMilk': 1077,
'CustomerServiceRequest': 'Off',
'4645': 0,
'CoffeeMilkOrder': 'FirstCoffee',
'BackendConnected': True,
'BeverageCounterCoffee': 21,
'Enjoy': 'Off',
'UserMode': 'Barista',
'PlaceEmptyGlassUnderOutlet': 'Off',
'WaterTankNotInserted': 'Off',
'PlaylistRunning': False,
'BeverageCounterPowderCoffee': 9,
'DemoModeActive': False,
'CleanBrewingUnit': 'Off',
'WaterHardness': 'Medium',
'CloseDoor': 'Off',
'EmptyMilkTank': 'Off',
'SpecialRinsing': 'Off',
'AllowConsumerInsights': False,
'SwitchOffAfter': '01Hours15Minutes',
'4681': 0,
'LastSelectedCoffeeWorldBeverage': 20514,
'BrightnessDisplay': 7,
'CleanMilkTank': 'Off',
'NotEnoughWaterForThisKindOfBeverage': 'Off',
'ChildLock': False,
'4666': 0,
'Language': 'De',
'MilkContainerConnected': 'Off',
'SoftwareUpdateAvailable': 'Off',
'LeaveProfilesAutomatically': True,
'RemoveWaterFilter': 'Off',
'OperationState': 'Inactive',
'BeverageCounterHotMilk': 9,
'4362': 0,
'MilkTubeRemoved': 'Off',
'DeviceIsToCold4C': 'Off',
'SystemHasRunDry': 'Off',
'DeviceShouldBeDescaled': 'Off',
'PowerState': 'Standby',
'DeviceShouldBeCleaned': 'Off',
'DeviceShouldBeCalcNCleaned': 'Off',
'BeanContainerEmpty': 'Off',
'MilkStillOK': 'Off',
'CoffeeOutletMissing': 'Off',
'MilkReminder': 'Off',
'RefillEmptyWaterTank': 'Off',
'RefillEmptyBeanContainer': 'Off',
'UnderOverVoltage': 'Off',
'NotEnoughPomaceCapacityForThisKindOfBeverage': 'Off',
'AdjustGrindSetting': 'Off',
'InsertWaterFilter': 'Off',
'FillDescaler': 'Off',
'CleanFillWaterTank': 'Off',
'PlaceContainerUnderOutlet': 'Off',
'SwitchOffPower30sekBackOn': 'Off',
'ThrowCleaningDiscInTheDrawer': 'Off',
'RemoveMilkContainer': 'Off',
'RemoveContainerUnderOutlet': 'Off',
'MilkContainerRemoved': 'Off',
'ServiceProgramFinished': 'Off',
'DeviceDescalingOverdue': 'Off',
'DeviceDescalingBlockage': 'Off',
'CustomerServiceConnectionAllowed': False,
'BeverageCountdownCleaning': 38,
'ProcessPhase': 'None'
}
Moved to README-frida.md