Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Define window width and window level based on 2-98 percentiles saturates the high pixel intensities that usually cause the image to and makes the brightness and contrast more similar across different types of scanners.
This fixes #745 the visualization issue only for MRIs imported with NIfTI, but not with DICOM.
Tested with 3 different MRIs that were previously being visualized very dark in InVesalius.