Skip to content

MEAS MS5611 pressure sensor library for altitude / variometer applications, uses floating point for better resolution

Notifications You must be signed in to change notification settings

har-in-air/ms5611

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

4 Commits
 
 
 
 
 
 
 
 

Repository files navigation

ms5611

MEAS MS5611 pressure sensor library for altitude / variometer applications

Integer code provided in datasheet does not have adequate resolution for variometer (rate-of-climb) applications. So I've modified some of the computations to use floating point operations. This does not mean the improved-resolution pa measurements are more accurate. You will still need noise-filtering algorithms to process the data. Sliding-window averaging is fine for barometric pressure/altimeter applications, but more sophisticated processing will be required for variometer applications. E.g. Kalman filtering, linear regression etc.

The pressure to altitude conversion is done via look up tables followed by linear interpolation. This is useful if using an 8bit/16bit processor and the processing time is critical. Accuracy can always be improved by decreasing the lookup table interval (more entries), but at the cost of code space.

Code assumes spi bit-bang interface to the MS5611.

About

MEAS MS5611 pressure sensor library for altitude / variometer applications, uses floating point for better resolution