Skip to content

gs4711/oh2

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

1 Commit
 
 
 
 

Repository files navigation

Velux Binding

This binding integrates the Velux devices with help of a gateway, the Velux Bridge KLF200, which is able to control 200 actuators. The Velux Binding interacts via the Velux Bridge with any io-homecontrol-based devices like window openers, shutters and others.

Based on the VELUX API this binding integrates Velux and other io-homecontrol devices directly into the openHAB, avoiding the necessity of any cloud-based mediation infrastructures. The complete home-automation will work even without any Internet connectivity.

For details about the features, see the following websites:

Overview

As the API is widely open, there are several use cases which are supported by the Bridge: From the complete configuration of a set of io-homecontrol devices including registration, naming, grouping, crypto key setup and exchange, the definition of intended settings, so called scenes, up to the control of single devices, i.e. open window of bathroom up to 45%.

The following areas are covered:

Topic Details
General bridge commands SW version(*), Gateway state(*), Learn state, Clock, Reboot, FactoryReset, Network Setup(+)
Configuration Services Node Discovery, Node Removal, Controller Copy, Crypto Key Generation, Crypto Key Exchange, Actuator config
Information Services House Monitoring Service(*), Node information(+), Group information
Activation Logging
Command Handling Command activation(*), Command interruption(*), Status Request(*), Actuator Identification(*), Limitations
Scene Handling Scene definition, Scene execution(*), Scene deletion, Scene renaming, Scene Overview(*)
Physical I/O Handling I/O Port setup

Items marked with (*) are fully implemented. Items marked with (+) have only partial support.

Binding Configuration

The Velux KLF200 bridge has to be configured with some parameters, at least with the IP address of the bridge.

Property Default Required Description
ipAddress Yes Hostname or address for accessing the Velux Bridge.
protocol slip No Underlying communication protocol (http/https/slip).
tcpPort 51200 No TCP port (80 or 51200) for accessing the Velux Bridge.
password velux123 No Password for authentication against the Velux Bridge.(**)
timeoutMsecs 1000 No Initial Connection timeout in milliseconds.
retries 5 No Number of retries during I/O.
refreshMsecs 10000 No Refresh interval in milliseconds.
isBulkRetrievalEnabled yes No Load all scenes and actuators in one step.
isSequentialEnforced no No Enforce Sequential Actuator Control even for long operations.
isProtocolTraceEnabled no No Show any protocol interaction (loglevel INFO).

(**) Note: This password is the API password that is printed on the back of the unit. Normally it differs from the password of the web frontend.

Advise: if you see a significant number of messages per day like

 communicate(): socket I/O failed continuously (x times).

please increase the parameters retries or/and timeoutMsecs.

For your convenience you'll see a log entry for the recognized configuration within the log file i.e.

2018-07-23 20:40:24.746 [INFO ] [.b.velux.internal.VeluxBinding] - veluxConfig[ipAddress=192.168.42.1,tcpPort=80,password=********,timeoutMsecs=2000,retries=10]

The Velux Things (beside the mentioned bridge) are Velux Window, Velux Rollershutter, and a generic Velux Actuator and Velux Scene. The 1st three Things have to be configured with an identification by their serial number.

Property Default Required Description
serial Yes Serial number of the io-homecontrol device.
name No (Optional) name of the io-homecontrol device.
inverted false No Inverts any device values.

The fourth Thing, the Velux Scene, has to be configured with an identification by their scenename.

Property Default Required Description
sceneName Yes Name of the io-homecontrol configuration.

The fifth Thing, the Velux Virtual Shutter, has to be configured with pairs of level combined with the appropriate scenenames.

Property Default Required Description
sceneLevels Yes ,,,,....
currentLevel 0 No Inverts any device values.

Discovery

Unfortunately there is no way to discover the Velux bridge itself within the local network. But after configuring the Velux Bridge, it is possible to discover all scenes and actuators like windows and rollershutters by the binding.

Item Configuration

The Items of a Velux Bridge consists in general of a pair of mastertype and subtype definition. In the appropriate items file, i.e. velux.items, this looks like

{ velux="thing=<Mastertype>;channel=<Subtype>" }

Optionally the subtype is enhanced with parameters like the appropriate name of the scene.

{ velux="thing=<Mastertype>;channel=<Subtype>#<Parameter>" }
Mastertype Description
binding Provides informations for easier configuration of this binding.
bridge The Velux KLF200 represents a gateway to all Velux devices.
scene Named ordered set of product states which can be activated for execution.
actuator Generic IO-home controlled device which can be maintained by parameter settings.
window IO-home controlled device of type window.
rollershutter IO-home controlled device of type rollershutter.
vshutter IO-home controlled device of type rollershutter.

Subtype

Subtype Item Type Description Mastertype Parameter
information String Describes the current state of the binding binding N/A
status String Current Bridge State (***) bridge N/A
reload Switch Reload information from bridge into binding bridge N/A
timestamp Number Timestamp of last successful device interaction bridge N/A
doDetection Switch Start of the product detection mode bridge N/A
firmware String Software version of the Bridge bridge N/A
ipAddress String IP address of the Bridge bridge N/A
subnetMask String IP subnetmask of the Bridge bridge N/A
defaultGW String IP address of the Default Gateway of the Bridge bridge N/A
DHCP Switch Flag whether automatic IP configuration is enabled bridge N/A
WLANSSID String Name of the wireless network bridge N/A
WLANPassword String WLAN Authentication Password bridge N/A
products String List of all recognized products bridge N/A
scenes String List of all defined scenes bridge N/A
check String Result of the check of current item configuration bridge N/A
shutter Rollershutter Virtual rollershutter as combination of different scenes bridge required
-------------- --------------- ----------------------------------------------------------------- ------------ -----------
serial String IO-Homecontrol'ed device (****) (*****) actuator required
position Rollershutter Position of the IO-Homecontrol'ed device (****) actuator optional
state Switch State of the IO-Homecontrol'ed device actuator optional
limitMinimum Rollershutter Minimum position of the IO-Homecontrol'ed device (****) actuator optional
limitMaximum Rollershutter Maximum position of the IO-Homecontrol'ed device (****) actuator optional
-------------- --------------- ----------------------------------------------------------------- ------------ -----------
sceneName String Defines the scene by name according to registration in KLF200 scene required
action Switch Activates a set of predefined product settings scene optional
silentMode Switch Modification of the silent mode of the defined product settings scene optional

Notes: (***) The existence of this item triggers the continuous realtime status updates of any Velux item like shutters even if they are manually controlled by other controllers.

(****) To enable a complete invertion of all parameter values (i.e. for Velux windows), add a trailing star to the eight-byte serial number. For an example, see below at item Velux DG Window Bathroom.

(*****) Somfy devices does not provides a valid serial number to the Velux KLF200 gateway: The bridge reports a registration of the serial number 00:00:00:00:00:00:00:00. Therefore the binding implements a fallback to allow an item specification with a actuator name instead of actuator serial number whenever such an invalid serial number occurs. For an example, see below at item Velux OG Somfy Shutter.

Subtype Parameters

In case of the scene-related subtypes, action and silentMode, the specification of the related scene as parameters is necessary;

{ velux="thing=scene;channel=<Subtype>#<Parameter>" }

The subtype shutter requires an even pair of parameters, each defining the shutter level and the related scene:

{ velux="thing=brigde;channel=shutter#<Level1>,<Scene1>,<Level2>,<Scene2>" }

Virtual shutter

As the bridge does not support a real rollershutter interaction, this binding provides a virtual rollershutter consisting of different scenes which set a specific shutter level. Therefore the item definition contains multiple pairs of rollershutter levels each followed by a scene name, which leads to this setting.

Items

Sample items file for textual configuration

Sitemap

Sample sitemaps file for textual configuration

Rules

Sample rules file for textual configuration

Things

Sample things file for textual configuration

More automation samples

At this point some interesting automation rules are included to demonstrate the power of this gateway to the io-homecontrol world.

Closing windows after a period of time

Especially in the colder months, it is advisable to close the window after adequate ventilation. Therefore, automatic closing after one minute is good to save on heating costs. However, to allow the case of intentional prolonged opening, an automatic closure is made only with the window fully open.

/*
 * Start of imports
 */

import org.openhab.core.library.types.*

/*
 * Start of rules
 */

rule "V_WINDOW_changed"
when
	Item V_WINDOW changed
then
	logInfo("rules.V_WINDOW",	"V_WINDOW_changes() called.")
	//
	// Get the sensor value
	//
	val Number windowState = V_WINDOW.state as DecimalType
	logWarn("rules.V_WINDOW", "Window state is "+windowState+".")
	if (windowState < 80) {
		if (windowState == 0) {
			logWarn("rules.V_WINDOW", "V-WINDOW changed to fully open.")

			var int interval = 1
	
        		createTimer(now.plusMinutes(interval)) [|
				logWarn("rules.V_WINDOW:event", "event-V_WINDOW(): setting V-WINDOW to 100.")
                		sendCommand(V_WINDOW,100)
				V_WINDOW.postUpdate(100)
    				logWarn("rules.V_WINDOW:event", "event-V_WINDOW done.")
        		]
    		} else {
			logWarn("rules.V_WINDOW", "V-WINDOW changed to partially open.")
		}
    	}
	//
	// Check type of item
	//
	logDebug("rules.V_WINDOW",	"V_WINDOW_changes finished.")
end

/*
 * end-of-rules/V_WINDOW.rules
 */

Debugging

For those who are interested in more detailed insight of the processing of this binding, a deeper look can be achieved by increased loglevel.

With Karaf you can use the following command sequence:

log:set TRACE org.openhab.binding.velux
log:tail

This, of course, is possible on command line with the commands:

% openhab-cli console log:set TRACE org.openhab.binding.velux 
% openhab-cli console log:tail org.openhab.binding.velux

On the other hand, if you prefer a textual configuration, you can append the logging definition with:

	<logger name="org.openhab.binding.velux" level="TRACE">
		<appender-ref ref="FILE" />
	</logger>

During startup of normal operations, there should be only some few messages within the logfile, like:

[INFO ] [i.dashboard.internal.DashboardService] - Started Dashboard at http://192.168.45.150:8080
[INFO ] [i.dashboard.internal.DashboardService] - Started Dashboard at https://192.168.45.150:8443
[INFO ] [rthome.model.lsp.internal.ModelServer] - Started Language Server Protocol (LSP) service on port 5007
[INFO ] [e.core.internal.i18n.I18nProviderImpl] - Location set to '49.035932145739444,8.455450258310762'.
[INFO ] [smarthome.event.ExtensionEvent       ] - Extension 'package-expert' has been installed.
[INFO ] [marthome.ui.paper.internal.PaperUIApp] - Started Paper UI at /paperui
[INFO ] [.ui.habmin.internal.servlet.HABminApp] - Started HABmin servlet at /habmin
[INFO ] [ding.velux.handler.VeluxBridgeHandler] - Initializing Velux veluxBridge handler for 'velux:klf200:7dff2548'.
[INFO ] [ome.event.ThingStatusInfoChangedEvent] - 'velux:klf200:7dff2548' changed from UNINITIALIZED to INITIALIZING
[INFO ] [ome.event.ThingStatusInfoChangedEvent] - 'velux:klf200:7dff2548' changed from INITIALIZING to UNKNOWN
[INFO ] [nal.VeluxValidatedBridgeConfiguration] - veluxConfig[protocol=slip,ipAddress=192.168.45.9,tcpPort=51200,password=********,timeoutMsecs=1000,retries=5,refreshMsecs=15000,isBulkRetrievalEnabled=true]
[INFO ] [ng.velux.bridge.slip.io.SSLconnection] - Starting velux bridge connection.
[INFO ] [hab.binding.velux.bridge.slip.SClogin] - velux bridge connection successfully established (login succeeded).
[INFO ] [ding.velux.handler.VeluxBridgeHandler] - Found velux scenes:
        Scene "V_Shutter_West_100" (index 5) with non-silent mode and 0 actions
        Scene "V_Shutter_West_000" (index 4) with non-silent mode and 0 actions
        Scene "V_Shutter_Ost_090" (index 10) with non-silent mode and 0 actions
        Scene "V_Window_Mitte_005" (index 3) with non-silent mode and 0 actions
        Scene "V_Window_Mitte_000" (index 1) with non-silent mode and 0 actions
        Scene "V_Window_Mitte_100" (index 2) with non-silent mode and 0 actions
        Scene "V_Shutter_West_090" (index 7) with non-silent mode and 0 actions
        Scene "V_Window_Mitte_010" (index 0) with non-silent mode and 0 actions
        Scene "V_Shutter_Ost_000" (index 8) with non-silent mode and 0 actions
        Scene "V_Shutter_Ost_100" (index 9) with non-silent mode and 0 actions       .
[INFO ] [ding.velux.handler.VeluxBridgeHandler] - Found velux actuators:
        Product "M_Rollershutter" / ROLLER_SHUTTER (bridgeIndex=4,serial=43:12:14:5A:12:1C:05:5F,position=0010)
        Product "O_Rollershutter" / ROLLER_SHUTTER (bridgeIndex=3,serial=43:12:40:5A:0C:23:0A:6E,position=0000)
        Product "M_Window" / WINDOW_OPENER (bridgeIndex=0,serial=43:12:3E:26:0C:1B:00:10,position=C800)
        Product "W-Rollershutter" / ROLLER_SHUTTER (bridgeIndex=1,serial=43:12:40:5A:0C:2A:05:64,position=0000)      .
[INFO ] [ding.velux.handler.VeluxBridgeHandler] - velux Bridge is online with 10 scenes and 4 actuators, now.
[INFO ] [ome.event.ThingStatusInfoChangedEvent] - 'velux:klf200:7dff2548' changed from UNKNOWN to ONLINE
[INFO ] [thome.event.ItemChannelLinkAddedEvent] - Link 'velux_klf200_7dff2548_status-velux:klf200:7dff2548:status' has been added.
[INFO ] [smarthome.event.ItemStateChangedEvent] - velux_klf200_7dff2548_status changed from NULL to GW_S_GWM/GW_SS_IDLE
[INFO ] [thome.event.ItemChannelLinkAddedEvent] - Link 'velux_klf200_7dff2548_timestamp-velux:klf200:7dff2548:timestamp' has been added.
[WARN ] [ding.velux.handler.VeluxBridgeHandler] - Exception occurred during activated refresh scheduler: null
[INFO ] [smarthome.event.ItemStateChangedEvent] - velux_klf200_7dff2548_timestamp changed from NULL to 1565646559977
[INFO ] [thome.event.ItemChannelLinkAddedEvent] - Link 'velux_klf200_7dff2548_products-velux:klf200:7dff2548:products' has been added.
[INFO ] [smarthome.event.ItemStateChangedEvent] - velux_klf200_7dff2548_products changed from NULL to 4_members:_Product_"M_Rollershutter"_/_ROLLER_SHUTTER_(bridgeIndex=4,serial=56:32:14:5A:12:1C:05:5F,position=0010),Product_"O_Rollershutter"_/_ROLLER_SHUTTER_(bridgeIndex=3,serial=53:09:40:5A:0C:23:0A:6E,position=0000),Product_"M_Window"_/_WINDOW_OPENER_(bridgeIndex=0,serial=56:23:3E:26:0C:1B:00:10,position=C800),Product_"W-Rollershutter"_/_ROLLER_SHUTTER_(bridgeIndex=1,serial=53:09:40:5A:0C:2A:05:64,position=0000)
[INFO ] [thome.event.ItemChannelLinkAddedEvent] - Link 'velux_klf200_7dff2548_scenes-velux:klf200:7dff2548:scenes' has been added.
[INFO ] [smarthome.event.ItemStateChangedEvent] - velux_klf200_7dff2548_scenes changed from NULL to 10_members:_Scene_"V_Shutter_West_100"_(index_5)_with_non-silent_mode_and_0_actions,Scene_"V_Shutter_West_000"_(index_4)_with_non-silent_mode_and_0_actions,Scene_"V_Shutter_Ost_090"_(index_10)_with_non-silent_mode_and_0_actions,Scene_"V_Window_Mitte_005"_(index_3)_with_non-silent_mode_and_0_actions,Scene_"V_Window_Mitte_000"_(index_1)_with_non-silent_mode_and_0_actions,Scene_"V_Window_Mitte_100"_(index_2)_with_non-silent_mode_and_0_actions,Scene_"V_Shutter_West_090"_(index_7)_with_non-silent_mode_and_0_actions,Scene_"V_Window_Mitte_010"_(index_0)_with_non-silent_mode_and_0_actions,Scene_"V_Shutter_Ost_000"_(index_8)_with_non-silent_mode_and_0_actions,Scene_"V_Shutter_Ost_100"_(index_9)_with_non-silent_mode_and_0_actions
[INFO ] [smarthome.event.ItemStateChangedEvent] - velux_klf200_7dff2548_timestamp changed from 1565646559977 to 1565646593645
[INFO ] [ig.discovery.internal.PersistentInbox] - Added new thing 'velux:scene:7dff2548:V_Shutter_West_100' to inbox.
...

Supported/Tested Firmware Revisions

The Velux Bridge in API version one (firmware version 0.1.1.*) allows activating a set of predefined actions, so called scenes. Therefore beside the bridge, only one main thing exists, the scene element. The next-generation firmware version two is not backward compatible, and does not provide a public web frontend, but version two does provide full access to any IO-Home compatible devices not limited to Velux and includes many different features.

Firmware revision Release date Description
0.1.1.0.41.0 2016-06-01 Default factory shipping revision.
0.1.1.0.42.0 2017-07-01 Public Web Frontend w/ JSON-API.
0.1.1.0.44.0 2017-12-14 Public Web Frontend w/ JSON-API.
2.0.0.71 2018-09-27 Public SLIP-API w/ private-only WLAN-based Web Frontend w/ JSON-API.

Notes:

  • Velux bridges cannot be returned to version one of the firmware after being upgraded to version two.
  • Firmware updates are currently provided at Velux download area.

Is it possible to run the both communication methods in parallel?

For environments with the firmware version 0.1.* on the gateway, the interaction with the bridge is limited to the HTTP/JSON based communication, of course. On the other hand, after upgrading the gateway firmware to version 2, it is possible to run the binding either using HTTP/JSON if there is a permanent connectivity towards the WLAN interface of the KLF200 or using SLIP towards the LAN interface of the gateway. For example the Raspberry PI can directly be connected via WLAN to the Velux gateway and providing the other services via the LAN interface (but not vice versa).

Known Limitations

The communication based on HTTP/JSON is limited to one connection: If the binding is operational, you won't get access to the Web Frontend in parallel.

The SLIP communication is limited to two connections in parallel, i.e. two different openHAB bindings - or - one openHAB binding and another platform connection.

Both interfacing methods, HTTP/JSON and SLIP, can be run in parallel. Therefore, on the one hand you can use the Web Frontend for manual control and on the other hand a binding can do all automatic jobs.

Unknown Velux devices

All known Velux devices can be handled by this binding. However, there might be some new ones which will be reported within the logfiles. Therefore, error messages like the one below should be reported to the maintainers so that the new Velux device type can be incorporated."

[ERROR] [g.velux.things.VeluxProductReference] - PLEASE REPORT THIS TO MAINTAINER: VeluxProductReference(3) has found an unregistered ProductTypeId.

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published