fixed bug when coaxial ports are snapped to grid cell boundaries. #1785
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
The previous fix I had made, only fixed one symptom of the true bug. The real issue was incorrectly placing some of the monitors and path integrals in cases where the load resistor was snapped to a grid cell boundary.
I added more testing for the lumped ports to ensure that snapping takes place correctly.