make
-
pipenv install
-
[optional] to identify interface:
3.1 udevadm monitor --udev
3.2 plug in co2 meter
3.3 get /hidraw/hidraw[x]
-
Plug-in co2 meter (if not yet)
-
export DATADOG_TOKEN=[DD-access-key]
-
export HID=<hid path from 3rd step> (e.g. /dev/hidraw1)
-
sudo -E bash -c 'python main.py' (or add in systemctl)
=========================================
Reverse engineered userspace driver for SLAB HT2000 CO2, temperature and relative humidity (RH) data logger made by Dongguan Xintai Instrument Co.
Full blogpost about reverse engineering this thing: http://globalblindspot.blogspot.be/2016/08/reverse-engineering-slab-ht2000-co2_11.html
Author: Tom Van Braeckel [email protected]