I assume you're using the 1st heating circuit. Do |
Hi
I have 2 circuits physically installed
the test:
thermostat read E3
Requesting type (0xE3) from dest 0x10
(00:16:18.816) Sending read of type 0xE3 to 0x10: telegram: 0B 90 E3 00 20
(CRC=D3), #data=1
(00:16:18.956) Thermostat -> me, type 0xE3 telegram: 10 0B E3 00 (CRC=73)
What is strange that when I set the thermostat to manual mode I receive the
temperature.
When switched back to Auto, the temp is gone
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: 21.5 C
Current room temperature: 22.0 C
Thermostat time is 21:23:35 4/4/2019
Mode is set to manual
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: ? C
Current room temperature: ? C
Thermostat time is 21:24:19 4/4/2019
Mode is set to auto
Thanks
M.
št 4. 4. 2019 o 20:41 Proddy <[email protected]> napísal(a):
… I assume you're using the 1st heating circuit. Do set log v and thermostat
read E3 and see if a telegram comes back.
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub
<#86 (comment)>, or mute
the thread
<https://github.com/notifications/unsubscribe-auth/AMurCAQdELxdNYNs_e1aKrryhbJm8Bkaks5vdkdggaJpZM4cdWwF>
.
|
the
and the mother of all tests is |
00:50:47.275) Sending read of type 0x48 to 0x10: telegram: 0B 90 48 00 20
(CRC=4D), #data=1
(00:50:47.474) Thermostat -> me, type 0x48 telegram: 10 0B 48 00 05 03 00
00 DB F0 3C 00 00 00 00 00 00 11 05 00 (CRC=41), #data=16
log t
System Logging set to Thermostat only
(00:51:55.935) Thermostat -> Boiler, type 0x14 telegram: 10 88 14 00 03
(CRC=6E), #data=1
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:52:00.999) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DB 66 05 00 00 00 00 00 00 00 05 00 (CRC=54), #data=16
(00:52:01.524) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:52:01.953) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 38 0F 03 01 (CRC=5F), #data=8
(00:52:08.695) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00 03
(CRC=0D), #data=3
(00:52:16.842) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E1 7D 00 7D 00 (CRC=7A), #data=13
(00:52:17.684) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:52:31.596) Thermostat -> all, type 0xA2 telegram: 10 00 A2 00 00 00 00
00 00 00 00 00 00 00 00 00 00 02 (CRC=9B), #data=14
(00:52:33.580) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 38 2F 03 01 (CRC=78), #data=8
(00:52:37.605) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
(00:52:38.448) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:52:48.492) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:53:00.723) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:53:01.266) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:53:01.709) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 39 0F 03 01 (CRC=57), #data=8
(00:53:08.947) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00 03
(CRC=0D), #data=3
(00:53:17.090) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:53:17.940) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:53:33.827) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 39 2F 03 01 (CRC=70), #data=8
(00:53:37.851) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
(00:53:38.694) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:53:48.806) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 00 1B
(CRC=66), #data=1
(00:53:48.832) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 00 33 4C
00 D6 93 01 0F 17 16 00 00 00 (CRC=9D), #data=12
(00:53:48.935) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 0C 1B
(CRC=7E), #data=1
(00:53:48.974) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 0C 33 4C
00 D6 93 01 11 16 23 00 00 00 (CRC=ED), #data=12
(00:53:49.065) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 18 1B
(CRC=56), #data=1
(00:53:49.113) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 18 33 4C
00 D6 93 01 11 16 22 00 00 00 (CRC=AB), #data=12
(00:53:49.181) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 24 1B
(CRC=2E), #data=1
(00:53:49.213) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 24 33 4C
00 D6 93 01 11 16 21 00 00 00 (CRC=61), #data=12
(00:53:49.681) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 30 1B
(CRC=06), #data=1
(00:53:49.719) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 30 33 4C
00 D6 93 01 11 16 20 00 00 00 (CRC=27), #data=12
(00:53:49.812) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 3C 1B
(CRC=1E), #data=1
(00:53:49.862) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 3C 33 4C
00 D6 93 01 04 16 32 00 00 00 (CRC=1F), #data=12
(00:53:49.931) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 48 18
(CRC=F5), #data=1
(00:53:49.964) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 48 33 4C
00 D6 93 01 03 16 23 00 00 00 (CRC=F0), #data=12
(00:53:50.063) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 54 0C
(CRC=D9), #data=1
(00:53:50.112) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 54 39 48
01 10 8D 05 05 12 3B 00 00 00 (CRC=04), #data=12
(00:53:50.431) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 00 1B
(CRC=62), #data=1
(00:53:50.466) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 00 36 4C
00 E5 93 01 03 16 22 00 00 00 (CRC=CC), #data=12
(00:53:50.562) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 0C 1B
(CRC=7A), #data=1
(00:53:50.610) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 0C 34 59
01 5F 91 08 09 10 11 00 00 00 (CRC=31), #data=12
(00:53:50.684) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 18 1B
(CRC=52), #data=1
(00:53:50.733) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 18 36 4C
00 E5 8D 01 0E 05 00 00 00 00 (CRC=A6), #data=12
(00:53:50.806) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 24 18
(CRC=29), #data=1
(00:53:50.839) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 24 36 41
00 E3 8C 09 0A 0E 0A 00 00 00 (CRC=16), #data=12
(00:53:51.307) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 30 0C
(CRC=15), #data=1
(00:53:51.355) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 30 36 41
00 E3 8C 09 0A 0E 09 00 00 00 (CRC=40), #data=12
(00:53:51.433) Thermostat -> 0x09, type 0x29 telegram: 10 89 29 00 01
(CRC=90), #data=1
(00:53:51.442) 0x09 -> Thermostat, type 0x29 telegram: 09 10 29 00 00
(CRC=B4), #data=1
(00:53:51.615) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
(00:53:56.181) Thermostat -> Boiler, type 0x14 telegram: 10 88 14 00 03
(CRC=6E), #data=1
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:54:01.972) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:54:02.530) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:54:02.950) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 3A 10 03 01 (CRC=33), #data=8
Publishing boiler data via MQTT
(00:54:09.194) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00 03
(CRC=0D), #data=3
(00:54:17.356) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:54:18.187) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:54:34.075) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 3A 2F 03 01 (CRC=68), #data=8
(00:54:38.106) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
Publishing boiler data via MQTT
(00:54:38.809) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:54:51.979) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:55:02.596) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:55:05.959) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 3B 13 03 01 (CRC=37), #data=8
(00:55:09.687) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00 03
(CRC=0D), #data=3
(00:55:17.592) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:55:18.437) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:55:34.963) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 3B 30 03 01 (CRC=1C), #data=8
(00:55:38.478) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
Publishing boiler data via MQTT
(00:55:39.064) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
št 4. 4. 2019 o 21:50 Proddy <[email protected]> napísal(a):
… the thermostat read E3 command fetches the temperatures from the RC35. In
your case it returns nothing back which is why it shows up as '?'. Can you
try two more things
thermostat read 48 (for HC2)
to see if anything comes back
and the mother of all tests is log t and leave it for 1-2 minutes and see
what messages are being broadcast by your RC35.
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub
<#86 (comment)>, or mute
the thread
<https://github.com/notifications/unsubscribe-auth/AMurCDkc4kST1dC-jopWZDb27zPAZcasks5vdleQgaJpZM4cdWwF>
.
|
one more test:
thermostat mode 1
Setting thermostat mode to 1
Write to 0x10 was successful
(00:58:45.393) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 01 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=4A), #data=27
Publishing boiler data via MQTT
Publishing thermostat data via MQTT
(00:58:45.813) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 1B 64
64 00 (CRC=08), #data=4
(00:58:53.356) Thermostat -> all, type 0x48 telegram: 10 00 48 00 04 01 00
00 DB F0 3C 00 00 00 00 00 00 00 05 00 (CRC=6D), #data=16
(00:58:53.767) Thermostat -> all, type 0x3D telegram: 10 00 3D 00 01 25 2B
25 08 28 00 01 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=B4), #data=27
(00:58:54.969) Thermostat -> all, type 0x3D telegram: 10 00 3D 1B 00 02 28
19 0A 01 00 FF 32 2D 00 F4 05 05 02 (CRC=F5), #data=15
info
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: 18.5 C
Current room temperature: 22.0 C
Thermostat time is 22:02:49 4/4/2019
Mode is set to manual
Calling scheduled data refresh from EMS devices...
(00:59:00.975) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 80 02 2B
00 DB 66 05 00 00 00 00 00 64 00 1B 00 (CRC=0A), #data=16
Publishing boiler data via MQTT
Publishing thermostat data via MQTT
(00:59:01.522) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 01 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=4A), #data=27
(00:59:02.070) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 16
04 03 0F 03 01 (CRC=FE), #data=8
Publishing boiler data via MQTT
Publishing boiler data via MQTT
thermostat read E3
(00:59:21.682) Thermostat -> me, type 0xE3 telegram: 10 0B E3 00 (CRC=73)
thermostat read 48
Publishing boiler data via MQTT
(01:02:07.967) Thermostat -> me, type 0x48 telegram: 10 0B 48 00 04 01 00
00 DB F0 3C 00 00 00 00 00 00 00 05 00 (CRC=05), #data=16
For Mode 1 the info comes back though reading E3 does not
št 4. 4. 2019 o 21:59 Majo <[email protected]> napísal(a):
… 00:50:47.275) Sending read of type 0x48 to 0x10: telegram: 0B 90 48 00 20
(CRC=4D), #data=1
(00:50:47.474) Thermostat -> me, type 0x48 telegram: 10 0B 48 00 05 03 00
00 DB F0 3C 00 00 00 00 00 00 11 05 00 (CRC=41), #data=16
log t
System Logging set to Thermostat only
(00:51:55.935) Thermostat -> Boiler, type 0x14 telegram: 10 88 14 00 03
(CRC=6E), #data=1
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:52:00.999) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DB 66 05 00 00 00 00 00 00 00 05 00 (CRC=54), #data=16
(00:52:01.524) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:52:01.953) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 38 0F 03 01 (CRC=5F), #data=8
(00:52:08.695) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00
03 (CRC=0D), #data=3
(00:52:16.842) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E1 7D 00 7D 00 (CRC=7A), #data=13
(00:52:17.684) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:52:31.596) Thermostat -> all, type 0xA2 telegram: 10 00 A2 00 00 00 00
00 00 00 00 00 00 00 00 00 00 02 (CRC=9B), #data=14
(00:52:33.580) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 38 2F 03 01 (CRC=78), #data=8
(00:52:37.605) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
(00:52:38.448) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:52:48.492) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:53:00.723) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:53:01.266) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:53:01.709) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 39 0F 03 01 (CRC=57), #data=8
(00:53:08.947) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00
03 (CRC=0D), #data=3
(00:53:17.090) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:53:17.940) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:53:33.827) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 39 2F 03 01 (CRC=70), #data=8
(00:53:37.851) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
(00:53:38.694) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:53:48.806) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 00 1B
(CRC=66), #data=1
(00:53:48.832) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 00 33 4C
00 D6 93 01 0F 17 16 00 00 00 (CRC=9D), #data=12
(00:53:48.935) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 0C 1B
(CRC=7E), #data=1
(00:53:48.974) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 0C 33 4C
00 D6 93 01 11 16 23 00 00 00 (CRC=ED), #data=12
(00:53:49.065) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 18 1B
(CRC=56), #data=1
(00:53:49.113) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 18 33 4C
00 D6 93 01 11 16 22 00 00 00 (CRC=AB), #data=12
(00:53:49.181) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 24 1B
(CRC=2E), #data=1
(00:53:49.213) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 24 33 4C
00 D6 93 01 11 16 21 00 00 00 (CRC=61), #data=12
(00:53:49.681) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 30 1B
(CRC=06), #data=1
(00:53:49.719) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 30 33 4C
00 D6 93 01 11 16 20 00 00 00 (CRC=27), #data=12
(00:53:49.812) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 3C 1B
(CRC=1E), #data=1
(00:53:49.862) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 3C 33 4C
00 D6 93 01 04 16 32 00 00 00 (CRC=1F), #data=12
(00:53:49.931) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 48 18
(CRC=F5), #data=1
(00:53:49.964) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 48 33 4C
00 D6 93 01 03 16 23 00 00 00 (CRC=F0), #data=12
(00:53:50.063) Thermostat -> Boiler, type 0x10 telegram: 10 88 10 54 0C
(CRC=D9), #data=1
(00:53:50.112) Boiler -> Thermostat, type 0x10 telegram: 08 10 10 54 39 48
01 10 8D 05 05 12 3B 00 00 00 (CRC=04), #data=12
(00:53:50.431) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 00 1B
(CRC=62), #data=1
(00:53:50.466) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 00 36 4C
00 E5 93 01 03 16 22 00 00 00 (CRC=CC), #data=12
(00:53:50.562) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 0C 1B
(CRC=7A), #data=1
(00:53:50.610) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 0C 34 59
01 5F 91 08 09 10 11 00 00 00 (CRC=31), #data=12
(00:53:50.684) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 18 1B
(CRC=52), #data=1
(00:53:50.733) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 18 36 4C
00 E5 8D 01 0E 05 00 00 00 00 (CRC=A6), #data=12
(00:53:50.806) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 24 18
(CRC=29), #data=1
(00:53:50.839) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 24 36 41
00 E3 8C 09 0A 0E 0A 00 00 00 (CRC=16), #data=12
(00:53:51.307) Thermostat -> Boiler, type 0x11 telegram: 10 88 11 30 0C
(CRC=15), #data=1
(00:53:51.355) Boiler -> Thermostat, type 0x11 telegram: 08 10 11 30 36 41
00 E3 8C 09 0A 0E 09 00 00 00 (CRC=40), #data=12
(00:53:51.433) Thermostat -> 0x09, type 0x29 telegram: 10 89 29 00 01
(CRC=90), #data=1
(00:53:51.442) 0x09 -> Thermostat, type 0x29 telegram: 09 10 29 00 00
(CRC=B4), #data=1
(00:53:51.615) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
(00:53:56.181) Thermostat -> Boiler, type 0x14 telegram: 10 88 14 00 03
(CRC=6E), #data=1
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:54:01.972) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:54:02.530) Thermostat -> me, type 0x3D telegram: 10 0B 3D 00 01 25 2B
25 08 28 00 02 00 05 05 2D 01 01 04 3C 05 3C 01 FF 3C FF 0E 05 05 02 02
(CRC=45), #data=27
(00:54:02.950) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 3A 10 03 01 (CRC=33), #data=8
Publishing boiler data via MQTT
(00:54:09.194) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00
03 (CRC=0D), #data=3
(00:54:17.356) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:54:18.187) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:54:34.075) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 3A 2F 03 01 (CRC=68), #data=8
(00:54:38.106) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
Publishing boiler data via MQTT
(00:54:38.809) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
(00:54:51.979) Thermostat -> all, type 0x48 telegram: 10 00 48 00 05 03 00
00 DC F0 3C 00 00 00 00 00 00 11 05 00 (CRC=63), #data=16
Publishing boiler data via MQTT
Calling scheduled data refresh from EMS devices...
(00:55:02.596) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=1E), #data=16
(00:55:05.959) Thermostat -> me, type 0x06 telegram: 10 0B 06 00 13 04 15
04 3B 13 03 01 (CRC=37), #data=8
(00:55:09.687) Thermostat -> 0x21, type 0xAC telegram: 10 21 AC 00 05 00
03 (CRC=0D), #data=3
(00:55:17.592) Thermostat -> all, type 0xA3 telegram: 10 00 A3 00 10 11 11
00 DC 00 E2 00 E2 7D 00 7D 00 (CRC=4A), #data=13
(00:55:18.437) Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11
(CRC=30), #data=2
(00:55:34.963) Thermostat -> all, type 0x06 telegram: 10 00 06 00 13 04 15
04 3B 30 03 01 (CRC=1C), #data=8
(00:55:38.478) Thermostat -> all, type 0x3E telegram: 10 00 3E 00 04 01 00
00 DC 66 05 00 00 00 00 00 00 00 05 00 (CRC=76), #data=16
Publishing boiler data via MQTT
(00:55:39.064) Thermostat -> Boiler, type 0x1A telegram: 10 08 1A 00 00 00
00 00 (CRC=91), #data=4
št 4. 4. 2019 o 21:50 Proddy ***@***.***> napísal(a):
> the thermostat read E3 command fetches the temperatures from the RC35.
> In your case it returns nothing back which is why it shows up as '?'. Can
> you try two more things
>
> thermostat read 48 (for HC2)
> to see if anything comes back
>
> and the mother of all tests is log t and leave it for 1-2 minutes and
> see what messages are being broadcast by your RC35.
>
> —
> You are receiving this because you authored the thread.
> Reply to this email directly, view it on GitHub
> <#86 (comment)>, or mute
> the thread
> <https://github.com/notifications/unsubscribe-auth/AMurCDkc4kST1dC-jopWZDb27zPAZcasks5vdleQgaJpZM4cdWwF>
> .
>
|
sorry, made a typo. It's 3E and not E3. But I can see the values are coming in nicely in the logs you sent. |
Hi
yes, my observation is that when the mode is Auto, it does not return
temperatures in info
When switching between modes, the temperature is sent in info.
I found one note regarding this similar issue in other issues:
#80 (comment)
This might be something to do with the RC35 software bug and the solution
might be switching modes ?(:-) before checking temperatures?
Mode Auto:
thermostat read 3E
(04:47:25.440) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01 *00
00 D8* 66 3C 00 00 00 00 00 00 00 05 00 (CRC=B3), #data=16
INFO:
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: ? C
Current room temperature: ? C
Thermostat time is 11:57:20 5/4/2019
Mode is set to auto
I wonder why at least the current temp is not shown, as the data payload
says: 00D8 = 216= 21.6 C. For the set temp it is 00, but current temp
value is available. Info shows "?" despite existing temp
*CHANGING MODE TO 1:*
thermostat read 3E
(04:52:02.562) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 80 02* 2B
00 D8* 66 3C 00 00 00 00 00 64 00 1F 00 (CRC=E5), #data=16
BOTH SET and CURRENT TEMP returned
*INFO:*
*Thermostat stats:*
* Thermostat type: RC35 (ProductID:86 Version:21.08)*
* Setpoint room temperature: 21.5 C*
* Current room temperature: 21.6 C*
* Thermostat time is 12:00:21 5/4/2019*
* Mode is set to manual*
*CHANGINGMODE TO 2:*
thermostat read 3E
(04:53:41.566) Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 04 01* 00
00 D8* 66 3C 00 00 00 00 00 00 00 1E 00 (CRC=85), #data=16
*Now again , in Auto mode the Set temp is gone, but the current is
available*
*but INFO is ? for both*
*Thermostat stats:*
* Thermostat type: RC35 (ProductID:86 Version:21.08)*
* Setpoint room temperature: ? C*
* Current room temperature: ? C*
* Thermostat time is 12:03:12 5/4/2019*
* Mode is set to auto*
pi 5. 4. 2019 o 9:00 Proddy <[email protected]> napísal(a):
… sorry, made a typo. It's 3E and not E3. But I can see the values are
coming in nicely in the logs you sent.
So right now I'm not sure exactly what the problem is anymore. Are you
saying if the thermostat mode is in auto and you do a 'refresh' the
temperatures don't get updated? It would help if you make an easy
reproducible test so you and I can find out what is not working. And look
at the code too and submit a pull request when any necessary changes.
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub
<#86 (comment)>, or mute
the thread
<https://github.com/notifications/unsubscribe-auth/AMurCN_k1AhG40c514rpcvCzLBcsTdaYks5vdvR1gaJpZM4cdWwF>
.
|
If you have 2 HC, then I would assume that your heating is on the 2nd one and if you have a floor-heating you have for sure the same issues like I had. I had the same issues like you and solved them by adapting the firmware (PR pending). Meanwhile you might want to give a try to my changes, which can also be found here.... For me all is now working using my firmware and internal commands "thermostat mode xxx" etc work again (and I added some additional commands). |
@lobocobra I've merged your changes into the latest dev. Thanks for the graet work. |
@proddy many thanks for merging. I shortly checked the new code and it works partially.... MQTT
CONSOLE
I will check which part of the adapted code does the difference. |
thanks for testing. change temp by mqtt => does not work - I confirm it works for me on a RC20. What do you see in the lof? thermostat stats - this also works for me and I don't see why it shouldn't for an RC35. What do you get printed exactly? thermostat mqtt reg. mess - so you want to always publish thermostat temperature values even if the values haven't changed? The logic now only sends if there is a difference since the last measurement. |
:-) While I still am searching for the reasons, let me meanwhile answer your questions....
|
I finally found the problem and will make a new PR. :-) BTW.... I get some good programming lessons here by looking at what and how you corrected my sniplets. Many thanks for that. :-) |
@majo551 As you have a similar setup to me, I believe that almost everything should workd |
Hi
I installed the EMS-ESP version 1.7.0b4
Info provided the temperatures now:
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: 21.5 C
Current room temperature: 22.9 C
Thermostat time is 11:49:26 14/4/2019
Mode is set to auto
I have to say though that I had to switch my boiler to the factory reset
few days ago . So it might work also due to this reset.
It seems that playing with telegram type 35 (DHW) caused unwanted
behavior with my boiler warm water functionality. The boiler did not wan to
prepare the warm water after few telegrams sent. I noticed my boiler and
thermostat use to send a different length telegram than in the
documentation:
https://domoticproject.com/ems-bus-buderus-nefit-boiler/#The_EMS_Bus
if you look at the description of 0x35 and the example, first thing that I
noticed is a typo(?) when in the telegram it says 33 not 35.
Second thing was that this sequence did not start the water warming at all
in an neither combinations of the code types (telegram type 35 or 33)
and values 35/39 for start
I even tried the built in shower functionality, and it seems for my Buderus
GB172 there might be a different telegram needed for this. Anyway after
playing with this telegram and the shower functionality my water warming
stopped completely which led to my boiler manual hard reset:-)
>>>>>>>>>
info
[image: image.png]
>>>>>>>>>>>
My Thermostat sends something like this (different to the documentation)
when I press DHW once button on RC35
Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 *11 33* (CRC=12),
#data=2
then I can find in the log :
0x30 -> Boiler, type 0x35 telegram: 30 08 35 00 00 00 00 (CRC=CE), #data=3
Thermostat -> Boiler, type 0x35 telegram: 10 08 35 00 11 11 (CRC=30),
#data=2
wheras the document says 0B 08 *33* 00 *39 (CRC)*
But to confirm the original question, I can see now the thermostat
temperatures in info.
M.
ne 7. 4. 2019 o 21:31 lobocobra <[email protected]> napísal(a):
… @majo551 <https://github.com/majo551>
Can you test the latest DEV code made by proddy and tell us, what is
working/not-working?
As you have a similar setup to me, I believe that almost everything should
workd
—
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub
<#86 (comment)>, or mute
the thread
<https://github.com/notifications/unsubscribe-auth/AMurCDsSJUxCXpu9lJIazUjXSb6_00qvks5vekeQgaJpZM4cdWwF>
.
|
the 33 vs 35 in that website is just a typo I think. So would it be useful to add this feature to this project too, like activate/deactivate the DHW once? I don't have an RC35 so never considered adding it. If so please create a new enhancement request. Can we close this issue if you have the temp values coming in correctly now? |
yes, we can close the issue with the temp not showing
ne 14. 4. 2019 o 13:28 Proddy <[email protected]> napísal(a):
… the 33 vs 35 in that website is just a typo I think. So would it be useful
to add this feature to this project too, like activate/deactivate the DHW
once? I don't have an RC35 so never considered adding it. If so please
create a new enhancement request.
Can we close this issue if you have the temp values coming in correctly
now?
—
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub
<#86 (comment)>, or mute
the thread
<https://github.com/notifications/unsubscribe-auth/ADF2WCEGMPAVHZFDRSTT25DPQMIONANCNFSM4HDVNQCQ>
.
|
Bug description
Set and Actual room temperature from RC35 thermostat is not read. The value provided in telnet using info is "? "
Steps to reproduce
*sending "info" in telnet *
Expected behavior
real values to be seen for set and room temperature
Screenshots
Additional context
Full output
EMS Bus stats:
Bus Connected=yes, Tx is active, # Rx telegrams=350, # Tx telegrams=0, # Crc Errors=55
Boiler stats:
Boiler type: Buderus GB172/Nefit Trendline (ProductID:123 Version:04.08)
Hot tap water: off
Central heating: off
Warm Water activated: on
Warm Water circulation pump available: on
Warm Water comfort setting: Eco
Warm Water selected temperature: 57 C
Warm Water desired temperature: 70 C
Warm Water current temperature: 44.1 C
Warm Water current tap water flow: 0.0 l/min
Warm Water # starts: 1420 times
Warm Water active time: 32 days 19 hours 0 minutes
Warm Water 3-way valve: on
Selected flow temperature: 5 C
Current flow temperature: 22.8 C
Return temperature: ? C
Gas: off
Boiler pump: off
Fan: off
Ignition: off
Circulation pump: off
Burner selected max power: 0 %
Burner current power: 0 %
Flame current: 0.0 uA
System pressure: ? bar
System service code: 0H (203)
Heating temperature setting on the boiler: 65 C
Boiler circuit pump modulation max power: 100 %
Boiler circuit pump modulation min power: 10 %
Outside temperature: 16.1 C
Boiler temperature: ? C
Pump modulation: 0 %
Burner # starts: 7759 times
Total burner operating time: 333 days 22 hours 0 minutes
Total heat operating time: 301 days 3 hours 0 minutes
Total UBA working time: 1334 days 18 hours 37 minutes
Solar Module stats:
Collector temperature: 42.8 C
Bottom temperature: 43.0 C
Pump modulation: 0 %
Pump active: off
Thermostat stats:
Thermostat type: RC35 (ProductID:86 Version:21.08)
Setpoint room temperature: ? C
Current room temperature: ? C
Thermostat time is 19:44:21 4/4/2019
Mode is set to auto