Entering calibration when channel is in error mode #102

Closed
prasimix opened this issue Apr 6, 2017 · 2 comments
Closed

Entering calibration when channel is in error mode #102

prasimix opened this issue Apr 6, 2017 · 2 comments
Milestone

Comments

@prasimix
Copy link
Member

prasimix commented Apr 6, 2017

When channel is for any reason in error mode (e.g. power board is simply not connected) it's still possible to enter calibration wizard from system settings page.

@prasimix prasimix added this to the M5 milestone Apr 6, 2017
mvladic added a commit that referenced this issue Apr 18, 2017
@prasimix
Copy link
Member Author

Start calibration wizard option is now disabled if channel is in error mode and channel name become invisible. Yet, Disable and Recalibrate options are still visible and enabled. That don't make lots of sense. Why not simply make invisible complete section for channel in error mode?

mvladic added a commit that referenced this issue Apr 18, 2017
@prasimix
Copy link
Member Author

Fixed