Notifications
You must be signed in to change notification settings - Fork 503
Backup & Restore
roboticsalign edited this page Aug 2, 2020
·
5 revisions
The backup includes deCONZ and Phoscon App specific data for groups, lights, scenes, ZigBee network settings and other data like deCONZ GUI node positions and names.
Two scenarios:
- Move ConBee / RaspBee to a new gateway / Raspberry Pi
- Move network to a new controller (e.g. in case ConBee breaks and needs to be replaced)
Note: The old controller must be powered off completely before launching the new controller. In the case of a RaspBee, shutting down the system is not enough -- power must be cut from the Raspberry Pi (otherwise the RaspBee is still active as long as the power supply is connected).
- Open Phoscon App
- Open the Menu and go to Gateway > Settings
- If you do not use the the Zigbee channel 15: manually change it in Gateway > advanced
- Open Phoscon App
- If it is a new installation and the commissioning.html page is shown, replace it with index.html in the browser URL bar.
- Open the Menu and go to Gateway > Settings
Home Remember : Not all devices listed here are supported by deconz.