Device Support Request Bitron 902010/32 Wall Thermostat #2248
Comments
I actually searching for a compatible wall thermostat so that not just the light can be controlled. The only Zigbee thermostat I found was the above one .... did anybody already check if its compatible with deCONZ?? |
Should already be supported according to #1003 |
Thank you for this information! I will order one and test. |
@easybeat Please give feedback |
This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs. Thank you for your contributions. |
@Coalado I finally got it tested and the device is recognized in Deconz but does not show up in Phoscon app. And I'm using Deconz adapter in ioBroker and there I can see it and it also updates the current temperature BUT if I change the setpoint on the device, this value is not coming through to ioBroker. But if I change the setpoint in ioBroker it shows up on the device. Can I test if the value is shown in Deconz if I change it on the device? This would mean that there is a problem with the ioBroker adapter and this here could be closed. Thank you for help. Beat |
You can easily do that via deconz GUI, if you read the attributes of the corresponding cluster (I presume thermostat cluster). |
Looks like the attribute reporting is not defined. You may want to try this for the attribute you marked https://github.com/dresden-elektronik/deconz-rest-plugin/wiki/How-to...#manually-configure-attribute-reporting |
OK will try this but is this a bug on this device integration?
Am 2020-09-21 22:28, schrieb SwoopX:
Looks like the attribute reporting is not defined. You may want to try
this
https://github.com/dresden-elektronik/deconz-rest-plugin/wiki/How-to...#manually-configure-attribute-reporting
--
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub [1], or unsubscribe
[2].
|
No, it's not specific to the device. More a topic for the default settings. |
Hi
yes after I configured the attribute reporting it is now working!
Thank you very much.
Kind regards
Beat
Am 2020-09-21 22:28, schrieb SwoopX:
Looks like the attribute reporting is not defined. You may want to try
this
https://github.com/dresden-elektronik/deconz-rest-plugin/wiki/How-to...#manually-configure-attribute-reporting
--
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub [1], or unsubscribe
[2].
|
@SwoopX Hi, I just realised that the battery level is also not "reported" and I don't get it in ioBroker at all. Is this a similar problem or could that be not handled correctly in the ioBroker adaptor? |
I dont see the battery percentage in there at all. Just the voltage ? The cluster for that is greyed out afaik. |
Hi
It would be really good if this device would be supported. Here the link https://www.amazon.de/Bitron-902010-32-BITRONVIDEO-Wandtermostat-ZigBee/dp/B016V7IJRG
I think a device like that is missing to integrate a heating system.
Kind regards
Beat