NOTE:
- This repository is a fork of https://github.com/nysbc/appion-protomo.
- CHPC developers should read through README-CHPC.md instead.
A Docker-based distribution of the Appion-Protomo fiducial-less tilt-series alignment suite.
Protomo aligns tilt-series based only on the accumulated SNR of the sample — no fiducials or features are used.
-
A modern operating system (Linux, MacOS, Windows) with 16+ GB of RAM (32+ GB is highly recommended).
-
Tilt-series stacks and tilt image information (ideally in SerialEM or TOMO4 format, including stacks and info files).
-
Basic Unix/Linux knowledge.
Do you have Docker installed? If not, click here
Click to expand
Download and install Docker 1.21 or greater for Linux or MacOS.
Consider using a Docker 'convenience script' to install (search on your OS's Docker installation webpage).
Launch docker according to your Docker engine's instructions, typically docker start
.
Note: You must have sudo or root access to install Docker. If you do not wish to run Docker as sudo/root, you need to configure user groups as described here: https://docs.docker.com/install/linux/linux-postinstall/
Note: You may need to update your Docker installation by commandline before being able to install Appion-Protomo.
Click to expand
Download and install Docker Toolbox for Windows.
Launch Kitematic.
If on first startup Kitematic displays a red error suggesting that you run using VirtualBox, do so.
Note: Docker Toolbox for MacOS has not yet been tested.
Click to expand
In Amazon EC2, search the public Amazon AMI instances for 'Appion-Protomo' and start an instance. This is a fully-configured Linux Docker Appion-Protomo with test datasets; everything is installed and ready to use!
This tutorial explains why Docker is used for Appion-Protomo.
Do you have Appion-Protomo installed in your Docker? If not, click here
Click to expand
git clone http://github.com/nysbc/appion-protomo
cd appion-protomo
./run.sh
Note: The installation directory will contain the data directory. It is recommended that you reserve at least 10 GB of space for each tilt-series alignment.
This performs the following operations (click to expand):
-
Downloads the semc/appion-protomo docker image from Docker Hub,
-
Creates a Docker volume to persist the Mariadb database,
-
Mounts
~/appion-protomo/emg/data
on the host side to/emg/data
inside the running container, -
Mounts the
mariadb-database
Docker volume to/var/lib/mysql
inside the running container, -
Mounts the
~/appion-protomo
directory to/local_data
inside the running container, -
Opens ports 80 for web traffic, 3306 for database traffic, and 5901 for VNC'ing into the running container,
-
Waits for the mysqld_safe database daemon to launch (for ~10 seconds, but could in rare instances take longer).
Click to expand
In the Kitematic search bar type: semc/appion-protomo
.
Select appion-protomo v1.2.2 ('latest' is currently broken, sorry!).
Click Create
on the semc
appion-protomo
repository and wait for the container to download and start.
In Windows, you may need to tweak your settings (click to expand)
If you needed to run Docker using VirtualBox, then you will need to increase the amount of RAM allocated to Docker:
-
Stop the Docker container,
-
Open VirtualBox,
-
Shut down the running virtual machine,
-
Edit the Settings for the virtual machine you just shut down,
- Increase the RAM to 8+ GB,
-
Re-start the container.
Click to expand
Everything is already installed and ready to use!
Is this your first time using Appion-Protomo in your Docker? If so, click here
Make sure Docker is running:
- On CentOS or Ubuntu, type:
sudo systemctl start docker
. - On OSX with Docker Toolbox, launch the 'Docker Quickstart Terminal'.
- On Windows, Kitematic launches Docker automatically.
Click to expand
- If you have not already launched the Appion-Protomo container, do:
./run.sh
- You should run Appion-Protomo commands from inside a VNC viewer as appionuser and not as the root user. First, download and install a VNC viewer such as TigerVNC or RealVNC:
https://bintray.com/tigervnc/stable/tigervnc/1.9.0
https://www.realvnc.com/en/connect/download/viewer/macos/
Use your IP and TCP port like 192.168.99.100:5901
as the VNC address with password appion-protomo
.
You might try
docker-machine ip
to find your IP.
Here are some more possible IP addresses/names: localhost, 0.0.0.0, 127.0.0.1, 192.168.0.1
- To ssh into the container as root, do:
./exec.sh
Click for additional Docker Appion-Protomo container commands
- To kill the container (this does not delete the container), do:
./kill.sh
(Warning, this will kill any other Docker containers you have running as well, use with caution!)
- To remove delete the container, but not the mounted data in /emg/data or the volume at /var/lib/mysql, do:
./rmContainers.sh
(Warning: This will delete any other inactive containers you may have running as well!)
- To delete the mariadb-database volume, do:
./rmVolume.sh
(Warning: This will delete the database and anything you have uploaded in Appion! The volume will be recreated the next time you do ./run.sh, but you will have an empty Appion database!)
- To re-build the appion-protomo image from scratch, do:
./build.sh
(This will take a while!)
- To access the Appion webviewer, navigate to:
http://192.168.99.100
(Your IP address will vary depending on your Docker installation. Possible addresses: localhost, 0.0.0.0, 127.0.0.1, 192.168.0.1)
Click to expand
-
To get to Appion-Protomo in your web browser, in Kitematic click on
Settings
theHostname/Ports
. Click on the IP next to Docker Port 80. -
This should open your web browser to the Apache test page. Append
/myamiweb/
to the URL to access Appion.
Click for images
- This should open up your web browser to the displayed address:
- Append
/myamiweb/
to the address:
- To VNC into the container, download and install a VNC viewer such as TigerVNC or RealVNC:
https://bintray.com/tigervnc/stable/tigervnc/1.8.0
https://www.realvnc.com/en/connect/download/viewer/windows/
Use the IP and port found in the running Kitematic container's Settings >> Hostname/Ports
next to Docker port 5901
as the VNC address with password appion-protomo
.
Single particle tilt-series from EMPIAR-10129)
Click to expand:
Expected results after following this example tutorial
- Initial tilt-series before any alignment:
- Tilt-series (left) and reconstruction (right) after coarse alignment:
- Tilt-series (left) and reconstruction (right) after Appion-Protomo refinement:
Upload first SerialEM-formatted tilt-series to a new session
Make sure your container is running via the ./run.sh
script.
- From inside the appion-protomo directory (on the host machine, not inside the container), do the following:
Download the following hemagglutinin SerialEM tilt-series (collected on an F20 with a DE-20; from [EMPIAR-10129]):
https://drive.google.com/open?id=1remm05G-R7w_6GLjW1R_jmV6Qzg0fcMx
tar -zxvf HAslow1.tar.gz <your appion-protomo/emg/data/tiltseries/ directory>
./exec.sh
> Now we are inside the container
For Windows you need to copy tilt-series to the container because there are no mounted drives. Click for image instructions
- Click on
DOCKER CLI
on the bottom-left of Kitematic:
- Nativate to the directory containing your tilt-series, use
docker ps
to get your container id, and usedocker cp
to copy the directory's contents to the container:
- Now your tilt-series should be in /home/appionuser/ in your container:
- Navigate to your web portal at an address like
192.168.99.100/myamiweb
Select Project DB
Select Add a new project
- Fill in the form for your project and click
add
Select View Projects
Select the link on the name of your newly created project (NOT the pencil-editing icon)
Select create processing db
and wait for the page to reload
Select upload images to new session
- On the next page click the dropdown for
Images grouped by
and selectSerialEM Tilt Series
Enter a description for Session Description
Enter the microscope's Cs value (2.0 mm for the provided hemagglutinin tilt-series)
Enter the SerialEM stack path
Enter the SerialEM mdoc path
Enter the voltage
(200 kV for the provided hemagglutinin tilt-series)
Select Just Show Command
at the bottom of the page.
- On the next page, copy the entire uploadSerialEM.py command
Next, VNC to vnc://192.168.99.100:5901
(replace with your VNC ip:port) with password appion-protomo
Paste the command to a terminal prompt and hit enter
- Wait for uploadSerialEM.py to finish processing.
Note: If uploadSerialEM.py
gives an error regarding binning, then edit the file and change line 79 to: binning = 1 . This bug will be fixed in the next version.
Click for images
- The tilt-series has been uploaded. Now let's go see it:
- All information from the SerialEM mdoc file has been imported - order of collection (for dose compensation), magnification, defocus, pixelsize, dose, and tilt angles. Tilt images are listed in chronological order from bottom to top.
Upload additional SerialEM-formatted tilt-series to an existing session
Place multiple SerialEM stacks and mdoc files (each pair with the same basename) into emg/data/tiltseries
Remove or move the previously-uploaded tilt-series stack and mdoc files.
- Navigate to 192.168.99.100/myamiweb
Select Image Viewer
Make sure your project is selected in the dropdown (you should now see images in the image viewer panel)
If you don't see images then you first need to upload one tilt-series to a new session.
Click processing
at the top
-
On the next page click
Upload more images
on the left -
On the next page click the dropdown for
Images grouped by
and selectSerialEM Tilt Series
Enter the SerialEM directory path
Enter the voltage
Select Just Show Command
at the bottom of the page
- On the next page, copy the entire uploadSerialEM.py command
Next, VNC to vnc://192.168.99.100:5901
with password appion-protomo
Paste the command to a terminal prompt and hit enter
- Wait for uploadSerialEM.py to finish processing.
Coarse align tilt-series
-
Navigate to your session in the image viewer and click
processing
. -
On the next page click
Align Tilt-Series
on the left. -
On the next page click
Protomo 2.4.1
. -
On the next page, Protomo Coarse Alignment, select the tilt-series you wish to align from the box.
- This will fill in the
Run name
and present a number of parameters below.
- This will fill in the
Note: All parameters in the Appion-Protomo tilt-series alignment workflow contain extensive help files that are accessible by simply pointing at the parameter name.
For most samples select 10 nm
as the Object Size
in Parameter Presets
.
Choose whether you wish to Estimate Defocus of the Untilted Plane
or Dose Compensate
the tilt-series.
Dose compensation often helps tilt-series alignment unless your sample is particularly thick, as is often the case with FIB-milled specimen.
Select Just Show Command
at the bottom of the page.
- On the next page, copy the entire protomo2aligner.py command and run it in the Docker container.
Click [Click here to View Coarse Alignment Results after protomo2aligner.py --coarse has been run] →
.
-
On the next page, Protomo Coarse Alignment Summary, watch the
Tilt-Series After Coarse Alignment
video.-
If there are any tilt images that are grossly shifted relative to the others then proceed to the next section
Manually fix tilt-series if necessary
. If not, proceed ontoRefine tilt-series
. -
If there are any tilt images that contain objects that significantly occlude objects of interest, take note of their tilt angles.
-
Note: The objects in the tilt-series that move the least image-to-image will have a higher chance of being closest to the center of the tomogram after refinement. See the Critical Note in the upcoming 'Refine tilt-series' section.
Manually fix tilt-series if necessary
- If there are any tilt images that are grossly shifted relative to the others then continue through this section.
Copy the command at the bottom of the Protomo Coarse Alignment webpage beginning with /usr/bin/python
.
- VNC into your Docker container.
Paste the command into a terminal in the container.
Follow the bolded instructions that first appear after running the manual alignment command.
Practically, find an object that you think might be near the middle of the ice and align each image such that this object does not move on the screen.
Note: The objects in the tilt-series that move the least image-to-image will have a higher chance of being closest to the center of the tomogram after refinement. See the Critical Note in the upcoming 'Refine tilt-series' section.
Refine tilt-series
-
On the Protomo Coarse Alignment Summary webpage click on
[Click here to continue onto Refinement if the Coarse Alignment results are satisfactory] →
. -
On the next page, select
Basic
orAdvanced
Settings Verbosity
.
For most tilt-series, select 10 nm object(s) - Steep lowpass
as the Object Size
in Parameter Presets
.
Select the largest Search Area
that is in common between all tilt-images in the previously-viewed tilt-series in Parameter Presets
.
-
If there are any tilt images that need to be removed, input their tilt angles in the
General Parameters
, as anAngle Limit
and/or usingExclude Images by Tilt Angles
. -
If the tilt-series was manually aligned, choose
More Manual
forBegin with Coarse Alignment Results or Initial Alignment?
in theGeneral Parameters
. -
Under
Window Parameters
, input comma-separated values for the estimatedThickness(es)
, where the thickness corresponds to the thickness of the objects to be aligned to or their combined thickness.
Select Just Show Command
at the bottom of the page.
- On the next page, copy the entire protomo2multirefine.py or protomo2aligner.py command and run it in the Docker container.
On the left under Align Tilt-Series
click ## runs processing or finished
to access the main alignment summary webpage.
- On the Protomo Alignment Summary webpage you can watch as each tilt-series aligns.
Note: The tilt-azimuth for each microscope relative to Appion-Protomo convention needs to be determined experimentally. Protomo will often refine the tilt azimuth properly after 10-50 iterations. Once this value is known, it should be inputted into all future tilt-series alignments for that microscope in the General Parameters during Coarse Alignment.
Note: The alignment thickness cannot be determined prior to tilt-series alignment. If a tilt-series alignment did not align as well as you wish, try re-aligning with additional alignment thickness values.
Critical Note: The objects in the search area (technically, search volume defines by the [search area] x [thickness]) in a Protomo reconstruction video are the objects that are being used for tilt-series refinement. The highest SNR objects are typically driven towards the middle of the reconstruction/search volume in the z-direction during iterative alignment. If the alignment thickness is not chosen appropriately, this can cause the following issues:
- If the sample consists of single particles in 200 nm thick ice, for instance, where the particles are on both air-water interfaces, then an alignment thickness less than ~200 nm will likely align to only one of the layers of particles whereas an alignment thickness greater than ~200 nm will likely align to both layers of particles. In this scenario, if the particle is ~10 nm in extent, then two completely different alignment thicknesses might be found to be ideal: ~10 nm and ~200 nm. However, if the alignment using the ~10 nm alignment thickness is reconstructed, the layer of particles that was aligned to will be well resolved while the layer of particles that was not aligned to will be less well resolved. If the alignment using the ~200 nm alignment thickness is reconstructed, both layers of particles will be well resolved. Thus the ~200 nm alignment should be used and the ~10 nm alignment should probably be discarded even though they both report that they are well aligned.
- If the sample consists of a roughly uniformly dense set of objects, such as a FIB-milled cellular lamella or reconstituted proteins on liposomes, then alignment thicknesses up to and including the thickness of the entire sample slab in the search area might align well, however the alignment closest to the thickness of the sample slab will likely align most accurately.
- Alignment thicknesses chosen to be significantly larger than the sample thickness will likely align worse than alignment thicknesses that are roughly the same as the sample thickness.
Assess refinement
A tilt-series refinement should be assessed in the following ways:
- (if possible) Watch the tilt-series video to see if the alignment is potentially good. Are any images clearly shifted or rotated improperly?
- If so, then use the command at the bottom of the refinement iteration webpage to manually fix the bad tilt images and/or remove the bad tilt images. You will likely want to further refine the tilt-series before continuing.
- Watch the tilt-series correlation peak video at the top of the refinement iteration webpage - the small square video. All but one frame (usually the middle frame) should have a clear correlation peak in the center of the box. The reference frame (usually the middle one) should be black.
- If there are more than one black frames, then this means that the search area had to shrink during the refinement, which is often caused by a tilt image shifting too far. This might or might not be an issue. Note that this makes the tilt-series quality rating unreliable.
- If the correlation peaks are not clear, then there might not be enough signal in the search volume to align the tilt-series.
- A black box appears partway through the reconstruction video. This box is the search volume that was used during refinement. The alignment thickness should be chosen such that the signal-to-noise in the black box is maximized. If the box includes substantial 'empty' volume (e.g. vitreous ice or vacuum), then the alignment thickness might be too large. Converselly, if not all of the signal-producing objects are in the search volume, then the alignment thickness might be too small.
- (if possible) Pause the reconstruction video at the bottom of the refinement iteration webpage at or near the middle of the video. If there is an object visible near the middle of the reconstruction video, then find the object in the tilt-series video, point at that object with your finger or mouse cursor, and let the tilt-series video play through. That object should not move throughout the tilt-series video; ie. the object at the middle of a tilt-series reconstruction should not move in the tilt-series that it was reconstructed from.
- If the object does move, then manually align the tilt-series to re-position the bad tilt images so that the object at the middle of the reconstruction doesn't move. Then re-refine the tilt-series.
- If there are no objects near the middle of the reconstruction, then you might choose an object away from the center of the reconstruction and follow it through the tilt-series video. That object should move at a continuous rate across the screen. If that object accelerates or decelerates, then the bad tilt images probably need to be re-positioned so that the object moves at a continuous rate. Then re-refine the tilt-series.
- If the tilt-series satisfies assessments 1-4 above, then look at the Correction Factor Plots on the refinement iteration webpage. An impossibly perfect alignment will have all correction factors for all tilt images equal to zero. This isn't possible, largely due to ice deformations, beam-induced motion, beam damage, and low SNR. For a real tilt-series that is well-aligned, each tilt image will have a correction factor in x, y, and scaling below |1%| and a correction factor in rotation below |1°|. If there are any clear outliers, particularly at high tilt angles, consider removing those images before reconstruction.
Note: If the tilt-series satisfies assessments 1-4 above, then the alignment quality rating - Bad, Okay, Good, Very Good, Excellent, Perfection!, and Suspiciously Perfect... - should be reliable.
Secondary refinement assessments include:
- The tilt azimuth should be within ~0.5 degrees of the known tilt azimuth for the given microscope + goniometer combination.
- The geometry model - ie. the plot of phi, psi, and theta - should be stable before/after the iteration being analyzed.
- Ideally, the search volume should not be too small or too rectangular. Sometimes one highly shifted tilt image severely reduces the search area and might better be excluded from the refinement so that a larger search area can be used.
- You might not want the search volume to include grid substrate. Substrate will likely move differently than biological objects when exposed to the electron beam, unless the objects are securely attached to the substrate. The goal of Protomo alignment is to align to the biological objects - any motion during the tilt-series exposure of the objects in the search volume will limit the alignment quality. Carbon substrate in particular has very high signal and will drive the alignment.
Reconstruct/export tilt-series
Note: Before proceeding to reconstruction, always check the best iteration(s) of the tilt-series you wish to reconstruct on the Protomo Alignment Summary. At the very least, view the aligned tilt-series video to confirm that there are no visual issues.
From the Protomo Alignment Summary webpage, copy the runname
of the tilt-series you wish to reconstruct, and take note of the desired reconstruction iteration.
- Click on
Align Tilt-Series
on the left. Click onProtomo 2.4.1
. Select the tilt-series number you wish to reconstruct from the box.
Paste the runname
in place of the generated Run name
.
Select Just Show Command
at the bottom of the page.
-
On the next page click
[or Click here to Go Directly to the Reconstruction Page] →
. -
On the next page, the options and parameters you choose will depend entirely on the desired post-processing of your tilt-series or tomogram.
-
For visualization and particle picking, it is recommended that you dose compensate your tilt images before reconstruction if they have not yet been dose compensated and that you reconstruct using Tomo3D SIRT.
-
For sub-volume alignment, it is recommended that WBP be used (either Protomo WBP or Tomo3D WBP).
-
You may also export an aligned tilt-series stack. If you wish to export a non-dose compensated stack, choose
Dose Compensate > Reconstruct
underReconstruction Actions
, then changeDose Compensation Type
accordingly. If you choose aDose Compensation Type
other thanNone
, then the stack will not be dose compensated, instead a dose compensation script will be outputted so that you may process the aligned tilt-series stack further and dose compensate at a later time. This can be useful for CTF estimation and correction outside of Appion-Protomo.
Select the correct alignment iteration from which to reconstruct.
Input an appropriate reconstruction thickness.
Exclude any bad tilt images in the alignment.
Select Just Show Command
at the bottom of the page.
- On the next page, copy the entire protomo2reconstruction.py command and run it in the Docker container.
Note: The objects in the middle of the resulting tomogram were the objects in the middle of the search volume during tilt-series refinement.
Note: Protomo reconstruction will orient the tomogram in accordance with the refined tilt geometry while Tomo3D reconstruction will not. Thus if you pick particles in a Tomo3D SIRT reconstruction and wish to perform subvolume processing with WBP, you should choose reconstruct with Tomo3D WBP.
Note: If Tomo3D WBP is being used for sub-volume processing, consider using the additional Tomo3D option
-m 0.5
. This will remove the default application of a Hamming filter intended for cutting off high frequency noise. Hamming filters applied during reconstruction might cause anomalous high frequency correlation during subvolume alignment.
Additional features
Batch alignment
Since it is often difficult to determine the sample thickness a priori, batch refinement is rarely recommended, and is thus left to the user to test on their own.
However, batch coarse alignment is very useful for being able to quickly visualize and assess large datasets and batch defocus estimation is also useful.
To use batch alignment, first click Align Tilt-Series
and select any tilt-series from the list - this will load metadata into the browser. Then click on Batch Align Tilt-Series
.
Restarting a refinement
If you would like to refine a tilt-series that has already been refined, it is recommended that you first go to the refinement iteration on the Protomo Alignment Summary
page, scroll to the bottom, and run the protomo2manualaligner.py
command (even if you don't need to manually fix any images). Then navigate to Align Tilt-Series
on the left. Click on Protomo 2.4.1
. Select the tilt-series number you wish to refine from the box. Change the Run name to the name of the run that you manually aligned on a particular iteration (e.g. tiltseries0003_thick500). Click on Just Show Command
, Click on View Coarse Alignment Results
. Click on the link to continue onto Refinement.
Change the Starting Alignment under Parameter Presets
to Manual. If you do not want to re-refine beginning with binned by 8 alignment iterations, then click the <- Shift Rounds Left
link at the top of General Parameters
.
Upload a Generic Tilt Series
If you have a tilt-series that is not in SerialEM format (stack.mrc/.st and stack.mdoc) or TOMO4 format (stack_orig.st and stack.txt), then you can upload the tilt-series one of two ways:
-
Unstack the tilt-series into a separate folder, where the filenames are in the order in which the tilt-series was collected chronologically. The tilt images should have the file format and extension of .mrc. Then proceed to upload a
Generic Tilt Series
to a new session. Fill in the information in the bottom section of the form that corresponds to the tilt-series metadata (tilt image folder, binning, magnification, tilt angles, etc.). Note that the order of the tilt angles and dose list should be the same order as the unstacked tilt images. -
Unstack the tilt-series into a separate folder. The tilt images should have the file format and extension of .mrc. Create a txt file in the format of the example below (generated from the EMPIAR-10129 dataset in Example #1), where the first image corresponds to the first image collected and the last image to the last image collected. Then input the txt file instead of filling out the form as in 1).
/home/appionuser/HAslow1_tmp/HAslow1_0023.mrc 2.340000e-10 1 1 19000 -5.174180e-6 200000 17.999900 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0022.mrc 2.340000e-10 1 1 19000 -5.291560e-6 200000 15.146100 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0021.mrc 2.340000e-10 1 1 19000 -5.217900e-6 200000 12.249800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0020.mrc 2.340000e-10 1 1 19000 -5.231850e-6 200000 9.317380 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0019.mrc 2.340000e-10 1 1 19000 -5.187400e-6 200000 6.358640 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0018.mrc 2.340000e-10 1 1 19000 -5.206210e-6 200000 3.375980 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0017.mrc 2.340000e-10 1 1 19000 -5.204870e-6 200000 0.382592 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0016.mrc 2.340000e-10 1 1 19000 -5.199690e-6 200000 -2.618120 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0015.mrc 2.340000e-10 1 1 19000 -5.097580e-6 200000 -5.614440 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0014.mrc 2.340000e-10 1 1 19000 -5.077370e-6 200000 -8.601000 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0013.mrc 2.340000e-10 1 1 19000 -5.049780e-6 200000 -11.567100 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0012.mrc 2.340000e-10 1 1 19000 -5.022180e-6 200000 -14.507800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0011.mrc 2.340000e-10 1 1 19000 -4.983710e-6 200000 -17.410400 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0010.mrc 2.340000e-10 1 1 19000 -4.948330e-6 200000 -20.272500 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0009.mrc 2.340000e-10 1 1 19000 -4.916720e-6 200000 -23.088700 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0008.mrc 2.340000e-10 1 1 19000 -4.885120e-6 200000 -25.846400 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0007.mrc 2.340000e-10 1 1 19000 -4.925620e-6 200000 -28.541700 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0006.mrc 2.340000e-10 1 1 19000 -4.894820e-6 200000 -31.179800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0005.mrc 2.340000e-10 1 1 19000 -4.873330e-6 200000 -33.746200 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0004.mrc 2.340000e-10 1 1 19000 -4.851830e-6 200000 -36.240800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0003.mrc 2.340000e-10 1 1 19000 -4.961730e-6 200000 -38.658900 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0002.mrc 2.340000e-10 1 1 19000 -4.943290e-6 200000 -41.000800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0001.mrc 2.340000e-10 1 1 19000 -4.940540e-6 200000 -43.261700 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0024.mrc 2.340000e-10 1 1 19000 -5.815860e-6 200000 20.852200 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0025.mrc 2.340000e-10 1 1 19000 -5.902490e-6 200000 23.656800 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0026.mrc 2.340000e-10 1 1 19000 -5.905990e-6 200000 26.404200 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0027.mrc 2.340000e-10 1 1 19000 -5.964920e-6 200000 29.090200 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0028.mrc 2.340000e-10 1 1 19000 -6.009980e-6 200000 31.711700 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0029.mrc 2.340000e-10 1 1 19000 -5.930460e-6 200000 34.263000 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0030.mrc 2.340000e-10 1 1 19000 -5.937190e-6 200000 36.740500 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0031.mrc 2.340000e-10 1 1 19000 -5.944450e-6 200000 39.143000 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0032.mrc 2.340000e-10 1 1 19000 -5.951710e-6 200000 41.468300 3.186660
/home/appionuser/HAslow1_tmp/HAslow1_0033.mrc 2.340000e-10 1 1 19000 -5.958970e-6 200000 43.714100 3.186660
The columns are:
full_file_path pixelsize_in_meters binning_x binning_y magnification defocus_in_meters keV tilt_angle image_dose
Defocus refinement
Defocus estimation in Appion-Protomo is performed using TomoCTF, which measures the defocus of the untilted plane by tiling all tilt images together while taking into account the relative heights of each tile in order to use all of the signal in the tilt-series. This method of defocus estimation assumes that each tilt image's center was recorded with the sample at the same z-height in the microscope. This requires perfect tracking during collection, which is rarely achieved. As a result, Thon rings often become incoherent before they fade away towards Nyquist.
After tiling, TomoCTF searches monotonically from just below the lower defocus range requested to the top of the range. Often, the search finds the defocus that is one zero off from the correct defocus and so needs to be refined using a proper search range. During refinement, also consider adjusting the maximum reslution used for defocus searching - look at the upper-half of the previous defocus estimations (ie. the SNR of the untilted plane) to determine whether to increase or decrease the maximum reslution used for defocus searching.
-
From the Protomo Alignment Summary webpage, click on
Refine defocus
. -
On the next page, select the correct tilt-series number, change the defocus range appropriately, and edit other parameters appropriately.
Select Just Show Command
at the bottom of the page.
- On the next page, copy the entire protomo2reconstruction.py command and run it in the Docker container.
In-depth explanations & discussions
Protomo refinement basics
Protomo refinement is described with some mathematical clarity in the Protomo user's guide found on the original Protomo website.
Conceptually, Protomo alignment combines common lines and iterative preliminary weighted back-projection > reprojection correlation methods along with a robust geometry model of the entire stage and sample in order to effectively maximize SNR/contrast in the weighted back-projection, which might be equivalent to aligning the tilt-series if alignment parameters are chosen appropriately. As a result, tilt-series alignment with Protomo does not require fiducials or features, only SNR.
Appion-Protomo refinement on a coarsely aligned tilt-series generally proceeds as follows:
-
Pre-process all tilt images with lowpass and highpass filters, a median or gaussian filter, gradient subtraction, pixel intensity thresholds, masks, and mask lowpass and highpass apodization filters. All images are then binned during the first several Rounds of refinement.
-
A reference image is chosen (usually the tilt image closest to 0°). This image will not be moved during each refinement iteration.
-
The two images on either side of the reference image are aligned to the reference image by correlation inside of a given search area.
-
These three aligned tilt images are weighted back-projected into a preliminary 3D reconstruction.
-
A volume is selected from the preliminary 3D reconstruction and is then re-projected in the direction of the next highest tilt angle and the corresponding tilt image is then aligned (rotation, translation, and/or isotropic scaling) to this reprojection inside of a given search area.
- Alignment by correlation allows for sub-pixel accuracy. The alignment algorithm also allows for an estimation of the alignment error in rotation, translation, and/or scaling because it is calculated by matrix diagnolization, which numerically results in left over non-zero off-diagonal terms.
-
These four aligned tilt images are weighted back-projected into a preliminary 3D reconstruction, and step 5 proceeds with the next highest tilt image on the opposite side of the last-aligned tilt image (ie. alternating alignment between positive and negative tilt angles).
This process (steps 4 through 6) continues until all tilt images have been aligned.
-
After all tilt images are aligned, Protomo re-estimates the entire tilt model geometry (tilt azimuth, tilt elevation, and/or sample orientation in the ice).
-
Steps 1 through 7 are repeated over dozens of iterations with less and less binning and filtering.
Tilt-series alignment quality is then assessed semi-automatically by plotting the iterations versus the errors in alignment (see 5. indent), and should be additionally assessed by the user by checking tilt model geometry stability, that the alignment thickness has been chosen appropriately, and by simply watching the aligned tilt-series and reconstruction videos.
Protomo refinement metrics
As described in the Protomo refinement basics section above, Protomo estimates the accuracy with which it could align each tilt image rotationally, translationally, and/or with scaling. These errors, called correction factors, are expressed as a percentage of image length for translation and scaling, and in degrees for rotation. Correction factors are a measure of uncorrectable tilt image alignment error given the geometry model and the amount of uncorrectable drift, beam-induced motion, doming, and charging of the specimen during collection.
When you click on a refinement iteration summary, you will see four correction factor plots that show the estimated alignment error for each tilt image in the x-direction, y-direction, rotationally, and/or in scaling. The goal is to select the iteration (given sufficiently accurate alignment parameters - binning, lowpass, alignment thickness, etc.) with the least amount of errors. A good rule of thumb is that all tilt images should have correction factors below 1% (and 1° for rotation) before considering reconstruction and post-processing.
Each correction factor plot, except for rotation, additionally has plotted the mean correction factor (solid line) plus/minus one standard deviation (dotted lines). Green lines are good, red lines are bad.
To simplify the assessment of these correction factors, a combined metric (CCMS plot) is plotted on the main refinement summary webpages:
- The dotted orange line records the average + 1 standard deviation of the x correction factor and y correction factor, summed.
- The x'd orange line records the average + 1 standard deviation of the scaling correction factor.
- The blue line records the average + 1 standard deviation of the rotation correction factor.
- The black line is a scaled sum of the above three lines.
The goal then becomes to minimize the black line.
To simplify this process further, the main Protomo Alignment Summary webpage locates the lowest points on the black line and grades the alignment quality depending on how low the line is at that iteration: Bad, Okay, Good, Very Good, Excellent, Perfection!, and Suspiciously Perfect...
As a secondary metric, the stability of the geometry model should be checked.
Protomo limitations
[Global alignment using a section of all tilt images - alignment is restricted by the overall 3D sample movement and drift in the search area, objects outside of the search area might not be aligned as well as inside the search area for the same reasons.]
Common alignment issues
- In general, Protomo and Appion-Protomo can align any tilt-series that has high enough SNR. All sample types are alignable — single particles of all sizes, filaments, microtubules, liposomes, (pseudo-)crystalline arrays (2D and 3D), reconstituted proteins on membranes, cryosections, FIB/SEM lamella, thin cells — however, some sample geometries are particularly difficult.
If the field of view of a tilt-series is dominated by rotational or translational (pseudo-)symmetry, per-image rotations or translations might diverge. To help guide tilt-series alignment of such samples, always begin refinement with a tilt-series that is decently aligned to the eye (no obvious errors) and determine the tilt azimuth beforehand to within a few degrees. (For rotationally symmetric samples in particular,) turn onCheck Azimuth Stability
in Advanced General Refinement Parameters, or turn off Tilt Azimuth Refinement inGeometry Refinement Parameters
. This will help avoid rotational alignment divergence. (For translationally symmetric samples in particular,) adjust theTranslational Limit
appropriately inCross-Correlation Parameters
. After making these adjustments, attempt refinement using a wide and dense range of sample thicknesses.
If the tilt-series is still unalignable, perform refinement using only low tilt angles (~ -30°:30°). If the low angle tilt-series is alignable, manually add the high tilt images back into the Protomo .tlt file in the tilt-series run directory. (This last possible step must be performed manually as there is currently no method built into Appion-Protomo for adding tilt images back into a tilt-series alignment. Use theMy tlt file
option inStarting Alignment
to insert the tlt file back into Appion-Protomo.)
[Discuss thickness, tilt azimuth, search area, individual bad/misaligned tilt images...]
Common collection issues
[Discuss grid hole edge in images, drift, beam-induced motion, doming, charging, tracking, dose (SNR), ...]
CTF estimation and correction
Currently Appion-Protomo in Docker does not include tilt-series CTF correction. We have not yet robustly tested TomoCTF correction in Appion-Protomo to ensure that tilt-series are being CTF corrected properly.
CTF correction can be accomplished through a number of different methods that are not discussed in depth here.
The following list orders CTF estimation and correction methods by their approximate accuracy (from most accurate to least) based on a typically-collected tilt-series of a reasonably thick specimen (~100+ nm) with uniformly-distributed particles in the z-direction:
-
Per-particle tilt image fine estimation and correction that takes into account overlapping objects in each tilt image of each particle and accounts for the 3D location of each particle.
-
Per-particle tilt image fine estimation and correction that accounts for the 3D location of each particle.
-
Collecting high-dose focus images on either side of the target along the tilt axis for every tilt image and using the average of those defocus estimations along with the known 3D locations of particles to correct (given that the focus images are at a known height relative to the field of view of interest).
-
Per-tilt-series estimation and correction based on the accumulated SNR of the entire tilt-series, often found by tiling each tilt image together.
-
Per-tomogram estimation based on sufficient sub-tomogram processing where the zeros are found in the resulting sub-tomogram alignment's FSC curve.
-
Per-tilt image estimation and correction.
Reasons for not using fiducials
Heavy objects, such as gold beads or gallium ion deposits from FIB-milling, may be used as fiducials to determine the tilt-series alignment parameters that best localize the fiducials in 3D space. However, relying on fiducials may cause several issues:
-
Fiducials limit imageable areas. Ideally, 10-20 fiducials should be scattered uniformly throughout the ice in the desired field of view, which would allow for linear deformations in the ice to be accounted for during tilt-series alignment by using software such as TomoAlign. However, uniform dispersion of fiducials rarely occurs. Instead, fiducials are often scattered on one or both ice surfaces. Furthermore, many desired exposure areas either have too few fiducials, too many fiducials, or aggregated fiducials, causing the areas to either be unalignable with fiducials or heavily contaminated with fiducials.
-
Fiducials may occlude objects of interest. Sometimes an object of interest is directly next to a fiducial, and since fiducials show fringing artifacts, the contrast and power spectra of the objects of interest vary greatly from objects not near fiducials. Also, an object of interest far away from fiducials may still have fiducials in the projection direction of some tilt images. These distant fiducials then contaminate the power spectra of those tilt images and subvolumes.
-
Fiducials move differently than the sample. Fiducials primarily absorb electrons, which impart momentum on them and cause them to move differently than biological objects, which don't absorb as many electrons. Thus aligning to fiducials may result in a very accurate 3D model of the fiducials, but not the sample.
These issues reduce efficiency of collection and processing. However, if the sample has sufficient signal, then tilt-series alignment can be done with Appion-Protomo and all of these issues can be bypassed.
Resolution limits in cryoET
Resolution in cryoET is limited critically by pixelsize, SNR from the microscope/camera combination, the motion of objects of interest over the course of frame/image collection, the motion of objects of interest in 3D in the ice, and the accumulated dose on the sample. Here we will discuss these resolution limits in some detail.
-
The pixelsize of a tilt-series will determine the maximum possible resolution of any objects imaged (Nyquist = 2 x pixelsize = resolution limit). As with single particle cryoEM, this is a fundamental information limit due to the digitization of the electron beam at the image plane.
-
The SNR delivered by the microscope/camera combination determines the maximum resolution where the CTF can be estimated (if collection is done with defocus) and the maximum resolution where coherent structures can be aligned and averaged during sub-tomogram alignment and averaging.
Note: If tilt images are collected with a low dose (~< 5e-/A^2 per tilt image), it is common to find that more SNR exists in the power spectrum of the summed frames rather than the sum of the power spectra of all frames. The opposite is often true with higher dose images in single particle cryoEM.
- Tilt image collection at high magnification can cause beam-induced motion, often in the direction of tilt. Additionally, non-gold grids also often drift in the direction of tilt. The combination of uncorrectable directional movement between frames (or over the course of a whole whole image exposure if no frames are collected) will be the drift resolution limit of that tilt image. The drift resolution limit of the tilt-series will vary, depending on the dose weighting applied.
Note: CFlat carbon grids in particular can drift up to 100 angstroms during a ~3e-/A^2 exposure at tilts > 45 degrees.
- Several factors can contribute to the anisotropic motion of objects of interest in 3D in the ice during tilt-series collection. Two such factors are ice doming and differences between electron absorption between objects.
Ice doming is the effect where the ice bends in the direction roughly normal to the grid during electron exposure. This is sometimes noticeable in grid holes. If this occurs and if the motion is not uniformly normal to the grid, then the objects of interest will move relative to one another during collection. If the possibility of this movement is not taken into account during tilt-series alignment and/or sub-tilt-series refinement, then this will limit the resolution of the tomogram and subvolumes extracted from it. Protomo uses a central search area to align tilt images and thus if there is any doming in that area, then the alignment accuracy and resolution of objects in that area will be limited. Any objects outside of that search area will also be limited in alignment accuracy and resolution.
Differences in electron absorption between objects might occur because the objects of interest (including potentially fiducials) might be composed of atoms with significantly different electron cross sections. Different objects might absorb different amounts of energy and be deflected in different directions with different momentum transfers. As a result, objects might move with complicated relative motions during the full tilt-series exposure. Like with ice doming, if a sample is behaving in this way, then Protomo and fiducial alignment will be limited due to the global nature of the alignment methods. Refinement of sub-tilt-series may be able to track this movement and thus recover this resolution loss.
The lower bound of the overall resolution limit of a tilt-series might be expressed conceptually as:
max(Nyquist, CTF correction accuracy, maximum uncorrectable drift, anisotropic/3D motion of objects of interest, beam-induced specimen damage with respect to the orientations of the objects of interest, tilt-series alignment accuracy, [remaining factors])
PHP issues
Appion's, and thus Appion-Protomo's, front-end is built on PHP and thus inherits PHP's complications. The main issue that you as a user may find annoying is that sometimes it seems that Appion-Protomo webpages forget the tilt-series you were working on or complain that you haven't entered in something basic like pixelsize. This is often because PHP SESSION variables have been been cleared from your browser's cache. To refresh Appion-Protomo, you must reload these SESSION variables. You can do this by:
-
Navigate to
Align Tilt-Series
. -
On the next page click
Protomo 2.4.1
. -
On the next page, Protomo Coarse Alignment, select the tilt-series you wish to align from the box.
At this point all SESSION variables required for using Batch Align Tilt-Series, for instance, should be loaded.
Note that clicking on Align Tilt-Series forcefully clears all PHP variables. Selecting a tilt-series in Protomo Coarse Alignment populates basic PHP variables.
Here you will find additional example tilt-series alignments showing different samples types and alignment scenarios.
[to be added]
Click here
[to be added]
Click to expand:
Expected results after following this example tutorial
- Initial tilt-series before any alignment:
...
- Tilt-series (left) and reconstruction (right) after coarse alignment:
...
- Tilt-series (left) and reconstruction (right) after Appion-Protomo refinement:
...
Docker Appion-Protomo
- 01-29-2019 - v1.2.2
- Cleaned up bashrc (cosmetic changes).
- Added .pystartup so that python keeps terminal autocompletes from history (press up) because it can be useful.
12-12-2018 - v1.2.1
- Installation is about 10% smaller (removed libcufft.so from IMOD libraries - might put this back if determined necessary).
- Updated Readme to explain the proper method for restarting a tilt-series refinement.
- Updated Readme to explain the proper method for uploading a tilt-series that is not in SerialEM or TOMO4 format.
11-28-2018 - v1.2
- Reduced Docker size by removing unnecessary things.
- EMAN2 reliance has been removed and so EMAN2 has been removed (normalization of Tomo3D tomograms is now done with IMOD).
- Added more xterms and opened Firefox in VNC.
11-14-2018 - v1.1.4
- Removed a few unused packages and simplified Dockerfile a bit more. Also cleaned up Dockerfile and installation scripts.
11-11-2018 - v1.1.3
- Decreased the size of the Docker image by ~10% by optimizing the Dockerfile commands.
- Added screen to make it easier to run multiple jobs and kill jobs.
- Removed AdblockPlus because why was it there?
11-09-2018 - v1.1.2
- Fixed critical database creation issue since v1.1. Sorry!!
11-04-2018 - v1.1.1
- Created an Appion-Protomo Google Group so that users can discuss how to align tilt-series amongst themselves: https://groups.google.com/forum/#!forum/appion-protomo
08-14-2018 - v1.0.2
- README (this file!) significantly updated.
07-05-2018 - v1.0.1
- Version number added to Appion main page.
02-27-2018 - v1.0.0
- IMOD 4.10.11 Added.
- Tomo3D Added.
- TomoCTF Added.
- Root password has been changed to
appion-protomo
. - /emg/sw/ has been re-located to /sw/. This was creating issues because since /emg/data/ is shared between the host and Docker container, this was also locking the sw/ directory, preventing the user from removing software if they wish.
- /home/appionuser/.Xauthority permissions have been changed from root to appionuser (CentOS7 in particular had default permissions as root:root, which makes X11 in the VNC viewer fail).
- Spider, Xmipp, Relion, CTFfind3&4, and FindEM have been removed from the container.
12-05-2017
- Initial commit.
Appion-Protomo
- 01-29-2019 - v1.2.2
- Fixed a small bug in reconstruction file handling.
12-12-2018 - v1.2.1
- Enabled terminal output to the manual aligner (the -log flag in tomoalign-gui).
- Minor bugs.
11-28-2018 - v1.2
- Added TOMO4 support!
- Re-ordered upload pull-down menu.
- Added 'Upload more tilt-series' link to Appion menubar on the left at the bottom of Tomography.
- Simplified Appion homepage.
- Updated tips that show up after a protomo2XXXX.py command completes.
- Tomograms made with Tomo3D are now normalized.
- Minor bugs.
11-14-2018 - v1.1.4
- Collapsed the sidebar on the webpage for all sections except for Protomo.
- Clicking on 'processing' in imageviewer now goes directly to 'Align Tilt-Series'.
- Changed the link to the User Guide on the website to the github Appion-Protomo page, and added the same link to the Appion webpage.
- Added a link to the Google group to the Appion webpage and to the end of the python commands.
- Added a link from the refinement command generation page to the all-encompassing alignment summary page.
- Fixed minor errors in text.
11-09-2018 - v1.1.2
- The pixelsize is hardcoded into the raw image headers now, so it is passed on to the tilt-series stacks and tomograms properly.
- Added a link from Coarse alignment to Batch alignment.
- Fixed a small bug where if you only have 2 CPU cores then tilt-series videos wouldn't be made.
- Removed unused protomo*py scripts.
11-04-2018 - v1.1.1
- SerialEM stack uploading now re-names files that have bad characters in them, such as [ or ) or , or . etc. Uploaded tilt-series with these characters in the filename are likely to break the alignment workflow.
- Cleanup and small adjustments:
- Removed Shift Limit|Angle Limit from Basic Settings in Coarse Alignment. These generally aren't used or useful.
- For Express and Basic Settings in Coarse Alignment, the default is now to change the reference image for alignment to the image closest to zero degrees. This used to only be defaulted for Advanced Settings.
- Removed CMDiameter options from Refinement webpage - this feature is not yet implemented.
- Made it so Scale Factor switch adjusts properly when Rounds are shifted left.
- Protomo tlt files are now forcibly ordered from negative to positive tilt. Not doing this makes tilt-series videos display out of order.
10-29-2018 - v1.1
- Added the option to re-center tilt images after coarse alignment and manual alignment. In many circumstances, this can dramatically increase the available search area, thus improving the alignment and even allowing previously unalignable tilt-series to be aligned.
- Added the option to begin a manual alignment from a previous manual alignment.
- Added single-letter names for manual alignment starting options: 'o' for original, 'c' for coarse, 'i' for Imod, 'm' for manual.
- Fixed the Translational Limit parameter in refinement. It didn't change if you enter in a different value.
- If you go to the Refine webpage with a manually-fixed iteration from a previous alignment, it will now default to choosing 'Manual' as the Starting Alignment.
- Added the ability to create tilt-series and reconstruction videos after a manual alignment by adding '--create_videos' to the protomo2manualaligner.py command.
- Updated the Preset Parameters on the refinement webpage.
- Minor bug fixes.
08-14-2018 - v1.0.2
- Batch IMOD coarse alignment bug fixed.
07-05-2018 - v1.0.1
- Bug in SerialEM upload script fixed.
- Main summary webpage has been slightly simplified by combining a couple columns.
- Links to stacks added to bottom of main summary webpage.
02-27-2018 - v1.0.0
- IMOD coarse alignment added. With two coarse alignment methods, this increases its robustness and reduces the time required to manually align.
- Image transformations for reconstruction/stack export are now performed with a single 5th order spline interpolation using scipy.ndimage.interpolation.affine_transform. In previous releases, three interpolations were performed sequentially (translation, scaling, and rotation).
- The maximum search area is now calculated automatically. This frees the user from having to estimate this value by eye, increases the search area used for refinement, and reduces the likelihood of search area re-sizing during refinement, which increases the reliability of the quality metrics. This feature currently allows the user to set the search area to be a fraction of the maximum search area available at the beginning of refinement. Currently, the maximum search area is not updated for each iteration.
- Unaligned tilt-series stacks and SerialEM-formatted mdoc files can easily be exported (useful with Leginon-collected tilt-series where the user wishes to align their tilt-series using their Docker Appion-Protomo).
- The Translational Limit in Refinement is now implemented properly. Default is 10% of image length. This decreases the likelihood of alignment to false correlation peaks, as long as the tilt-series was properly coarsely aligned before refinement.
- Batch coarse alignment now tries to find an existing coarse_series####.param file in the current run directory.
- If tilt image frames have been aligned in Appion, then the maximum per-tilt image frame drift is plotted automatically for the corresponsing tilt-series, like this: https://i.imgur.com/RCLcLv8.png
- Backup of
/sw/myami/
: https://drive.google.com/open?id=1djw1s0GiK64mV-Dz4H2Mv5fKMUP8cRlB
12-05-2017
- Initial commit.
- Backup of
/emg/sw/myami/
: https://drive.google.com/open?id=1zOKzIVpatgY1FNsCYjvhBDyZiwEEXnBS
Noble, A. J., & Stagg, S. M. (2015). Automated batch fiducial-less tilt-series alignment in Appion using Protomo. Journal of Structural Biology, 192(2), 270–278. https://doi.org/10.1016/j.jsb.2015.10.003
Noble, A. J., Dandey, V. P., Wei, H., Brasch, J., Chase, J., Acharya, P., Tan Y. Z., Zhang Z., Kim L. Y., Scapin G., Rapp M., Eng E. T., Rice M. J., Cheng A., Negro C. J., Shapiro L., Kwong P. D., Jeruzalmi D., des Georges A., Potter C. S., Carragher, B. (2017). Routine Single Particle CryoEM Sample and Grid Characterization by Tomography. eLife. https://doi.org/10.7554/eLife.34257
Winkler, H., & Taylor, K. A. (2006). Accurate marker-free alignment with simultaneous geometry determination and reconstruction of tilt series in electron tomography. Ultramicroscopy, 106(3), 240–254. https://doi.org/10.1016/j.ultramic.2005.07.007
Lander, G. C., Stagg, S. M., Voss, N. R., Cheng, A., Fellmann, D., Pulokas, J., Yoshioka C., Irving C., Mulder A., Lau P.-W., Lyumkis D., Potter C. S., Carragher, B. (2009). Appion: An integrated, database-driven pipeline to facilitate EM image processing. Journal of Structural Biology, 166(1), 95–102. https://doi.org/10.1016/j.jsb.2009.01.002
Appion may be found here.
Appion-Protomo repository may be found here.
Protomo source code may be found here.
Appion and thus Appion-Protomo are open source software packages released under the Apache License, Version 2.0. Protomo itself is licensed under GPLv3.
Docker Appion-Protomo has been tested in Mac OSX El Capitan 10.11.3, Ubuntu 14.04.3 LTS, CentOS 7, Windows 10, and Amazon EC2.
Please report any bugs, problems, suggestions, or requests as a Github issue.
Here is a Google Group where users may discuss alignment strategies and compare notes.