Fix Hybrid Unitary Operating Settings Initialization #8422

Merged
merged 5 commits into from
Feb 1, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
13 changes: 8 additions & 5 deletions src/EnergyPlus/HybridEvapCoolingModel.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1270,11 +1270,6 @@ namespace HybridEvapCoolingModel {
Real64 PreviousMaxiumConditioningOutput = 0;
Real64 PreviousMaxiumHumidOrDehumidOutput = 0;
std::string ObjectID = Name.c_str();
int size = CurrentOperatingSettings.size();
CSetting empty_setting;
for (int i = 0; i < size; i++) {
CurrentOperatingSettings[i] = empty_setting;
}
if (StepIns.RHosa > 1) {
ShowSevereError(state, "Unitary hybrid system error, required relative humidity value 0-1, called in object" + ObjectID + ".Check inputs");
assert(true);
Expand Down Expand Up @@ -1853,6 +1848,14 @@ namespace HybridEvapCoolingModel {
UnitOn = 0;
ForceOff = true;
}

// Initialize all settings for all operating modes
int size = CurrentOperatingSettings.size();
CSetting empty_setting;
for (int i = 1; i < size; i++) {
CurrentOperatingSettings[i] = empty_setting;
}

// Go into standby if unit is off or not needed
if ((!CoolingRequested && !HeatingRequested && !VentilationRequested && !HumidificationRequested && !DehumidificationRequested) ||
ForceOff)
Expand Down
119 changes: 119 additions & 0 deletions tst/EnergyPlus/unit/UnitaryHybridAirConditioner.unit.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1388,4 +1388,123 @@ TEST_F(EnergyPlusFixture, Test_UnitaryHybridAirConditioner_ValidateOptionalError

}

TEST_F(EnergyPlusFixture, Test_UnitaryHybridAirConditioner_RuntimeFraction_Initialization)
{
std::vector<std::string> snippet = getAllLinesInFile2(configured_source_directory() + "/tst/EnergyPlus/unit/Resources/UnitaryHybridUnitTest_DOSA.idf");
std::string string = delimited_string(snippet);
ASSERT_TRUE(process_idf(string));
// setup environment
bool ErrorsFound(false);
GetZoneData(*state, ErrorsFound);
EXPECT_FALSE(ErrorsFound);
// Initialize schedule values
state->dataGlobal->TimeStep = 1;
DataHVACGlobals::TimeStepSys = 1;
state->dataGlobal->NumOfTimeStepInHour = 1;
state->dataGlobal->MinutesPerTimeStep = 60;
state->dataEnvrn->Month = 1;
state->dataEnvrn->DayOfMonth = 21;
state->dataGlobal->HourOfDay = 1;
state->dataEnvrn->DSTIndicator = 0;
state->dataEnvrn->DayOfWeek = 2;
state->dataEnvrn->HolidayIndex = 0;
state->dataGlobal->WarmupFlag = false;
state->dataEnvrn->DayOfYear_Schedule = General::OrdinalDay(state->dataEnvrn->Month, state->dataEnvrn->DayOfMonth, 1);
ScheduleManager::UpdateScheduleValues(*state);
// Initialize zone areas and volumes - too many other things need to be set up to do these in the normal routines
DataHeatBalance::Zone(1).FloorArea = 232.26;
state->dataEnvrn->StdRhoAir = 1.225;
state->dataEnvrn->OutBaroPress = 101325;
DataHeatBalance::ZoneIntGain.allocate(1);

SizingManager::GetOARequirements(*state);
GetOAControllerInputs(*state);
using DataZoneEquipment::CalcDesignSpecificationOutdoorAir;

// Setup performance tables
using namespace EnergyPlus::DataEnvironment;
// process schedules
ProcessScheduleInput(*state); // read schedules
UpdateScheduleValues(*state);
// Get Unitary system
GetInputZoneHybridUnitaryAirConditioners(*state, ErrorsFound);
// All to get OA requirements
GetOARequirements(*state);

EXPECT_FALSE(ErrorsFound);
// Initialize unit
InitZoneHybridUnitaryAirConditioners(*state, 1, 1);
Model *pZoneHybridUnitaryAirConditioner = &HybridUnitaryAirConditioners::ZoneHybridUnitaryAirConditioner(1);
// setup local variables for model inputs
Real64 Tosa, Tra, Wra, Wosa, RHosa, RHra, DesignMinVR, Requestedheating, RequestedCooling, Requested_Humidification, Requested_Dehumidification;
RHosa = 0;
std::string TimeDate;
Real64 MsaRatio, OSAF;
MsaRatio = OSAF = 1;

Requestedheating = RequestedCooling = Requested_Humidification = Requested_Dehumidification = 0;

DesignMinVR = 1.622720855; // Zone Hybrid Unitary HVAC Requested Outdoor Air Ventilation Mass Flow Rate
Tra = 22.93929413; // Zone Hybrid Unitary HVAC Return Air Temperature
Tosa = 26.67733333; // Zone Hybrid Unitary HVAC Outside Air Temperature
RHra = 17.3042157; // Zone Hybrid Unitary HVAC Return Air Relative Humidity
RHosa = 13.1602401; // Zone Hybrid Unitary HVAC Outside Air Relative Humidity
Wra = PsyWFnTdbRhPb(*state, Tra, RHra / 100, 101325);
Wosa = PsyWFnTdbRhPb(*state, Tosa, RHosa / 100, 101325);
pZoneHybridUnitaryAirConditioner->InletTemp = Tra;
pZoneHybridUnitaryAirConditioner->InletHumRat = Wra;
pZoneHybridUnitaryAirConditioner->InletEnthalpy = PsyHFnTdbRhPb(*state, Tra, RHra / 100, 101325, "test");
pZoneHybridUnitaryAirConditioner->InletPressure = 101325;
pZoneHybridUnitaryAirConditioner->InletRH = RHra / 100;
pZoneHybridUnitaryAirConditioner->SecInletTemp = Tosa;
pZoneHybridUnitaryAirConditioner->SecInletHumRat = Wosa;
pZoneHybridUnitaryAirConditioner->SecInletEnthalpy = PsyHFnTdbRhPb(*state, Tosa, RHosa / 100, 101325, "test");
pZoneHybridUnitaryAirConditioner->SecInletPressure = 101325;
pZoneHybridUnitaryAirConditioner->SecInletRH = RHosa / 100;

// Scenario 1: Low Cooling

Requestedheating = -64358.68966; //-
RequestedCooling = -633.6613591; // W
pZoneHybridUnitaryAirConditioner->Initialize(1);
pZoneHybridUnitaryAirConditioner->InitializeModelParams();
pZoneHybridUnitaryAirConditioner->doStep(
*state, RequestedCooling, Requestedheating, Requested_Humidification, Requested_Dehumidification, DesignMinVR);

// output results
Real64 Setting0Mode = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[0].Mode;
Real64 Setting0RuntimeFraction = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[0].Runtime_Fraction;
Real64 Setting1Mode = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[1].Mode;
Real64 Setting1RuntimeFraction = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[1].Runtime_Fraction;

// checks
EXPECT_EQ(Setting0Mode, 1); // IEC Mode
EXPECT_NEAR(Setting0RuntimeFraction, 0.547, 0.001); // IEC RTF
EXPECT_EQ(Setting1Mode, 0); // Standby Mode
EXPECT_NEAR(Setting1RuntimeFraction, 0.453, 0.001); // Standby Mode

// Scenario 2: Outside of env conditions. should go to standby and have standby energy
Requestedheating = -55795.8058;
RequestedCooling = 8171.47128;
pZoneHybridUnitaryAirConditioner->Initialize(1);
pZoneHybridUnitaryAirConditioner->InitializeModelParams();
pZoneHybridUnitaryAirConditioner->SecInletTemp = 150;
pZoneHybridUnitaryAirConditioner->SecInletHumRat = 0;
pZoneHybridUnitaryAirConditioner->doStep(
*state, RequestedCooling, Requestedheating, Requested_Humidification, Requested_Dehumidification, 0);

// output results
Setting0Mode = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[0].Mode;
Setting0RuntimeFraction = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[0].Runtime_Fraction;
Setting1Mode = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[1].Mode;
Setting1RuntimeFraction = pZoneHybridUnitaryAirConditioner->CurrentOperatingSettings[1].Runtime_Fraction;

// checks
EXPECT_EQ(Setting0Mode, 0); // Standby Mode
EXPECT_EQ(Setting0RuntimeFraction, 1); // Standby RTF
EXPECT_EQ(Setting1Mode, 0); // Standby Mode
EXPECT_EQ(Setting1RuntimeFraction, 0); // Standby RTF

}

} // namespace EnergyPlus