Most everything needed for your heater-system to be shown at your 'hometop' -> pimp your heater.
This project is limited to recording/controlling and presentation of heating and solar informations.
Currently only heater-systems from german manufacturer: Junkers
and system-bus: Heatronic/EMS2 (c)
are supported.
This repo can not fulfill all wishes you could have to your 'hometop'. Each has his ideas such as the 'home' can be 'Top'. The presentation of informations from the own 'home' with it's heater-system is what this repo will do. Other projects are working too on this item, example: FHEM
This repo was started creating some different boards for the RaspberryPi(c).
The table shows the currently available boards:
Board-name | function | remark |
---|---|---|
HT3_Mini_Adapter | receiving Bus - data | for RaspberryPi, see: Mini-Adapter |
HT3_Micro_Adapter | receiving Bus - data | any USB-hoster, see: Micro-Adapter |
ht_piduino | transmit- and receiving Bus - data | for RaspberryPi, see: ht_piduino |
ht_pitiny | transmit- and receiving Bus - data | for RaspberryPi, see: ht_piduino |
ht_motherboard | usb-interface for above boards | see: ht_motherboard |
The software is written in python and designed for detection, decoding and controlling of HT - busdata with following features:
Modul-name | function | remark |
---|---|---|
create_databases.py | tool for creating databases: sqlite and rrdtool. | configureable |
HT3_Analyser.py | GUI for system-data and raw-hexdump of decoded ht - busdata | configureable, default running as ht_proxy.client |
HT3_Systemstatus.py | GUI to show system-data only | configureable, default running as ht_proxy.client |
ht_collgate.py | Running as daemon starting interfaces for ht_data decoding, mqtt-IF and/or SPS-IF, running without GUI | configureable, default running as ht_proxy.client and sqlite = Off; rrdtool = On, mqtt_IF = Off, SPS_IF = Off. |
ht_proxy.py | ht-server to collect data from serial port and supporting connected clients with raw - busdata | configureable, default accepting any client |
ht_netclient.py | ht-client sending commands to the heater-bus | configureable, default connecting to 'localhost' |
ht_binlogclient.py | ht-client acts as logger of binary ht - busdata | configureable, default connecting to 'localhost' |
ht_client_example.py | ht-client acts as example for your one ht-client | configureable, default connecting to 'localhost' |
~/HT3/sw/etc/upgrade_rrdtool_db/ | upgrade tool for upgrading your old rrdtool - database to release:0.2 | read the 'readme_add_ds_2_rrd.txt' at first. |
For project - details see the documentation (folder: ~/HT3/docu
) and the following links:
- RaspberryPi HT-board forum: HT-Boards
- Software-forum: HT-Software
The current software can be found in subfolders: ~/HT3/sw/...
Any hardware informations are in subfolders: ~/HT3/hw/...
The software is still under development, but any official release should be runable 'out of the box' under Linux.
For Windows some improvements are required and will be done in the future.
If you have got any problems with hard- or software, let me know.
Also your support with binary - logfiles is good to have for further development.
Thank's to all supporting me, in the past and future.
We all want to have the right thing in the right time.
The reproduction and the commissioning of the adaptations is at your own risk and the description and software do not claim to be complete. A change of software modules and hardware descriptions at any time is possible without notice. Warranty, liability and claims by malfunction of heating or adaptation are hereby expressly excluded.
Der Nachbau und die Inbetriebnahme der Adaptionen ist auf eigene Gefahr und die Beschreibung und die Software erheben nicht den Anspruch auf Vollständigkeit. Eine Änderung an Software-Modulen und Hardware-Beschreibungen ist jederzeit ohne Vorankündigung möglich. Gewährleistung, Haftung und Ansprüche durch Fehlfunktionen an Heizung oder Adaption sind hiermit ausdrücklich ausgeschlossen.
03.12.2019
moduls
: Issue: Deprecated property InterCharTimeout #7; port.setInterCharTimeout() removed.
20.01.2019
moduls
: modified for new log-values, decoding upgraded for Cxyz Controller. See modul-header for details.- minor modifications in configuration-files, already used databases (from 0.3) can be used further on.
24.06.2017
moduls
:ht_collgate.py
,lib/Ccollgate.py
,lib/mqtt_client_if.py
andlib/SPS_if.py
added.modul
:andHT3_Logger.py
aren't used anymore and renamed to:./etc/sysconfig/ht3_logger
*unused
- New configuration-files added for ht_collgate, mqtt- and SPS- interfaces.
20.10.2016
autocreate_draw in minutes:
modified in moduls: ht3_worker.py, data.py, HT3_db_cfg.xml.3-bytes for solarpump-runtime:
modified in modul: ht_discode.py.tempniveau for FRxyz-controller:
added in moduls: ht_const.py, ht_yanetcom.py.
31.08.2016
wrong path-extraction:
corrected in modul: ht3_worker.py
29.08.2016
Complete redesign
of decoder and dispatcher using new modul:ht_discode.py
.- Support for new controller-type: Cxyz added.
moduls
:ht_yanetcom.py
andht_netclinet.py
are modified for handling with new controller-type: Cxyz.moduls
:andht3_dispatch.py
aren't used anymore and renamed to:ht3_decoder.py
ht3_*.py_unused
autocreate_draw
added in configuration-file: HT3_db_cfg.xml for updating rrdtool-draw every minute.- Default configured to:
On
.
- Default configured to:
autoerase_olddata
added in configuration-file: HT3_db_cfg.xml for deleting old dataentries in sqlite-db.- Default configured to:
30 days
.
- Default configured to:
db-table
:unused and deleted in sqlite-db.rrdtool_info
- rrdtool-db is updated instead every 60 seconds with all current data.
modul
:renamed to:db_info.py
db_info.py_unused
.MsgID
added for every decoded message displayed as hexdump.GUI
display-layout optimised for viewing all data.Autodetection
of heater-circuit amount and mixed-/unmixed-circuit(s) results also now in GUI-layout update.Displaycode
andCausecode
added in GUI, database and configuration-file.Betriebsstatus
added in GUI, database and configuration-file.- Values:
Manuell
andAuto
are available.
- Values:
Displayed times
changed from seconds to hours.Renaming
ofBetriebsart
toTemperatur-Niveau
in GUI, database and configuration-file.Betriebsart
still in database but not supported anymore.script: rrdtool_draw.pl
modified for items:Temperatur-Niveau
andBetriebsstatus
.accessname
added in configuration-file for requesting decoded data [currently unused].upgrade rrdtool_db
tool added for upgrading available rrdtool-database to this release: 0.2.-
you must have a lot of free space on your drive (> 1 GB in folder: /tmp) doing this upgrade.
-
the upgrade takes a lot of time do be finished.
-
if this space isn't available, remove the old database and create a new rrdtool-database.
-
importend notice
the current sqlite-database must be deleted or renamed and has to be recreated for this release:0.2 using tool: ./create_databases.py.
05.08.2016
never been an official release
. Used only for testpurposes.
27.04.2016
HeizkreisMsg_ID677_max33byte()
corrected.msg:9x00FF00()
handling with length of 10byte added.
22.02.2016
IPM_LastschaltmodulMsg()
fixed wrong HK-circuit assignment in ht3_decode.py.
10.02.2016
HeizkreisMsg_ID677_max33byte()
modified for better decoding.__GetStrBetriebsart()
update with value 4:="Auto".
07.02.2016
HeizkreisMsg_ID677_max33byte()
added for CWxyz handling.
04.03.2015
heizungspumpenleistung
added.- logging from ht_utils added.
10.01.2015
first
release on github.com.