Fix(JsYetiSimulator): 0 kw charging if pwm duty cycle was set to 5% #773

Merged
merged 1 commit into from
Jul 11, 2024

Conversation

SebaLukas
Copy link
Contributor

Describe your changes

If the duty cycle was set to 5% (HLC), the current was set to 0 amps. If HLC is now active, the correct current value is set.

Issue ticket number and link

Fixed issue #645

Checklist before requesting a review

  • I have performed a self-review of my code
  • I have made corresponding changes to the documentation
  • I read the contribution documentation and made sure that my changes meet its requirements

@SebaLukas SebaLukas merged commit 372906e into main Jul 11, 2024
8 checks passed
@SebaLukas SebaLukas deleted the fix/sil_zero_kw_charging_pnc branch July 11, 2024 05:41