Skip to content

The PyTorch re-implement of a 3D CNN Tracker to extract coronary artery centerlines with state-of-the-art (SOTA) performance. (paper: 'Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier')

License

Notifications You must be signed in to change notification settings

BubblyYi/Coronary-Artery-Tracking-via-3D-CNN-Classification

Repository files navigation

Coronary Artery Tracking via 3D CNN Classification Pytorch

The PyTorch re-implement of a 3D CNN Tracker to extract coronary artery centerlines with state-of-the-art (SOTA) performance. (paper: 'Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier')

Link to paper here.

Key idea

A 3D dilated CNN is trained to predict the most likely direction and radius of an artery at any given point in a CCTA image based on a local image patch. We use a 3D Fibonacci ball to model a CNN Tracker, where the radius of the ball represents the radius of the vessel at the current position, and the points on the ball represent a possible direction of movement.

Starting from a single seed point placed manually or automatically anywhere in a coronary artery, a tracker follows the vessel centerline in two directions using the predictions of the CNN.

Tracking is terminated when no direction can be identified with high certainty.

In order to create a vessel tree automatically, we need to train three neural networks.

  • Firstly, we need to train a centerline net to predict the two directions(d0, d1) of the current position that can be moved and the vessel radius.
  • Secondly, we need to train a neural network to find two entrance points of a coronary artery.
  • The third network is responsible for placing seed points in the image

Architecture of Centerline Net

Layer 1 2 3 4 5 6 7
Kernel width 3 3 3 3 3 1 1
Dilation 1 1 2 4 1 1 1
Channels 32 32 32 32 64 64 D+1
Field width 3 5 9 17 19 19 19

The number of output channels is equal to the number of potential directions in D, plus one channel for radius estimation.

The architecture of seedspint_net and ostiapoint_net are very similar to centerline_net. The only difference is in the output layer: instead of combining classification and regression, the final layer only performs regression.

Installation

To install all the required dependencies:

$ pip install -r requirement.txt

Training

1. Preparing CTA08 dataset

⚠ Tip:
CAT08 datasets need to be registered and certified in this website before it can be downloaded. It should be noted that your registration email may not be received by the server of the above website. If you have this problem, download this form, compile it and contact Dr.Theo van Walsum ([email protected]).

  1. Unzip training.tar.gz to:
    Coronary-Artery-Tracking-via-3D-CNN-Classification/
            -data_process_tools/
                -train_data/
                    -dataset00/
                    -dataset01/
                    -dataset02/
                    -dataset03/
                    -dataset04/
                    -dataset05/
                    -dataset06/
                    -dataset07/
  1. Create spacing_info.csv and nii.gz data
python3 creat_spacinginfo_data_tool.py
  1. Create centerline patch data
  • Create no offset samples
python3 centerline_patch_generater_no_offset.py
  • Create samples with offset
python3 centerline_patch_generater_offset.py
  1. Create seeds patch data
  • Create positve samples
python3 seedpoints_patch_generater_postive.py     
  • Create negative sample
python3 seedpoints_patch_generater_negative.py

those scripts will automaticlly create folders

-data_process_tools/
    -patch_data/
         -centerline_patch/
            -no_offset/
                 -point_500_gp_1/
                     -d0/
                     d0_patch_info_500.csv 
                     .
                     .
                     .
                     -d7/
                     d7_patch_info_500.csv
            -offset/
                  -point_500_gp_1/
                     -d0/
                     d0_patch_info_500.csv
                     .
                     .
                     .
                     -d7/
                     d7_patch_info_500.csv
  1. Create osita patch data
  • Create positve samples
python3 ostiapoints_patch_generater_positive.py
  • Create negative sample
python3 ostiapoints_patch_generater_negative.py

It should be noted that 8 samples corresponding to the data will be produced here, and the specific training set and test set division also need to write your own code to divide the data set and generate the train CSV file and val CSV file

2.Training Models

  1. Training centerline net
cd centerline_train_tools/
CUDA_VISIBLE_DEVICES=0 python3 centerline_train_tools.py
  1. Training seedpoints net
cd seedspoints_train_tools/
CUDA_VISIBLE_DEVICES=0 python3 seeds_train_tools.py
  1. Training ostiapoints net
cd ostiapoints_train_tools
CUDA_VISIBLE_DEVICES=0 python3 ostia_train_tools.py 

3.Create coronary artery vessels tree

cd infer_tools_tree/

First, you need to modify settingy.yaml replacing the path inside to the path of the file you saved

python3 vessels_tree_infer.py

The predicted vessel tree is shown in the figure below

The vessels from different seed points are spliced by breadth-first search, and then a complete single vessel is generated by depth-first search

Seedpoints net will generate 200 seed points as shown in the figure below. It can be seen that the seed points are distributed near several coronary arteries

References

@article{wolterink2019coronary,
  title={Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier},
  author={Wolterink, Jelmer M and van Hamersvelt, Robbert W and Viergever, Max A and Leiner, Tim Leiner, Ivana},
  journal={Medical image analysis},
  volume={51},
  pages={46--60},
  year={2019},
  publisher={Elsevier}
}

About

The PyTorch re-implement of a 3D CNN Tracker to extract coronary artery centerlines with state-of-the-art (SOTA) performance. (paper: 'Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier')

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages