encoder: lossless encode with BYPASS(1) + RESTART(4) mode results in lossy image #906

Closed
boxerab opened this issue Mar 25, 2017 · 1 comment

Comments

@boxerab
Copy link
Contributor

boxerab commented Mar 25, 2017

PSNR is around 50, so there seems to be quite a bit of loss.

There already is an issue open regarding BYPASS mode, but I think we still need this issue, since RESTART changes how raw passes are terminated - even with BYPASS fixed, the combination may still be broken.

@rouault
Copy link
Collaborator

rouault commented Jun 13, 2017

Fixed per #949