#!/usr/bin/env python
import sys
import requests
import time
# Run this script as:
# without parameters, it will toggle the power state and leave in manual mode
# with paramterer on or off, it will toggle to the selected state and leave in manual mode
# with parameter on or off and a numeric value, will toggle the switch to selected state for the selected amount of seconds. Will clean manual mode
# Enter the values below.
# Get a full list of relays data at: http://localhost:8090/api/relays/ and find the relay you need. Copy the value of the field 'id'
POWER_SWITCH_ID = "8ff3901484877cabb1f409eaf6c3b6ed"
ADMIN_NAME = "admin"
ADMIN_PASSWORD = "password"
TERRARIUMPI_SERVER = "http://localhost:8090"
# !!! No changes below this line !!!
action = "auto"
timeout = 0.0
if len(sys.argv) >= 2:
if "auto" == sys.argv[1]:
action = "auto"
elif sys.argv[1] in [1, "1", "On", "on", "true", "True"]:
action = "on"
else:
action = "off"
if len(sys.argv) == 3:
try:
timeout = float(sys.argv[2])
except Exception:
raise ValueError("Invalid timeout specified")
if action in ["auto", "on", "off"]:
power_switch_state = requests.get(
"{}/api/relays/{}/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID), auth=(ADMIN_NAME, ADMIN_PASSWORD)
)
if power_switch_state.status_code != 200:
raise RuntimeError("Not able to read power switch data...")
power_switch_state = power_switch_state.json()
# This script will break into the normal power switch state, so we need to put it in 'manual mode' despite the action is on or off.
# Also this will leave the system in manual mode as well... :(
if not power_switch_state["manual_mode"]:
manual_mode = requests.post(
"{}/api/relays/{}/manual/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID), auth=(ADMIN_NAME, ADMIN_PASSWORD)
)
if manual_mode.status_code != 200:
raise RuntimeError("Not able to put switch in manual mode...")
power_switch_state["manual_mode"] = True
if "auto" == action:
# Just toggle the state.....
switch_action = requests.post(
"{}/api/relays/{}/toggle/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID), auth=(ADMIN_NAME, ADMIN_PASSWORD)
)
else:
# Switch to specified sate
switch_action = requests.post(
"{}/api/relays/{}/{}/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID, ("off" if "off" == action else "on")),
auth=(ADMIN_NAME, ADMIN_PASSWORD),
)
if switch_action.status_code != 200:
raise RuntimeError("Not able to change the power switch state...")
# If we want the state go back to what it was, specify a timeout
if timeout > 0.0:
# Wait the specified time in seconds.... yes, will just sleep the script
time.sleep(timeout)
if "auto" == action:
switch_action = requests.post(
"{}/api/relays/{}/toggle/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID),
auth=(ADMIN_NAME, ADMIN_PASSWORD),
)
else:
switch_action = requests.post(
"{}/api/relays/{}/{}/".format(
TERRARIUMPI_SERVER, POWER_SWITCH_ID, ("on" if "off" == action else "off")
),
auth=(ADMIN_NAME, ADMIN_PASSWORD),
)
if switch_action.status_code != 200:
raise RuntimeError("Not able to change the power switch state...")
# Put manual mode to off... if it was off when we started
# This is only done when a timeout is specified
if power_switch_state["manual_mode"]:
# put out off manual mode
manual_mode = requests.post(
"{}/api/relays/{}/manual/".format(TERRARIUMPI_SERVER, POWER_SWITCH_ID),
auth=(ADMIN_NAME, ADMIN_PASSWORD),
)
if manual_mode.status_code != 200:
raise RuntimeError("Not able to put switch out of manual mode...")