Added SIGINT handler for stlink cleanup #135
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
SIGINT causes st-util to immediately exit, without closing the open
stlink. This leaves devices (at least the F4 Discovery) in a state
where they are unable to reset. st-util could still connect and control
them, but a power cycle was required before they could reset on their
own.
A signal handler is added for SIGINT, which performs cleanup and closing
of the open stlink device, allowing it to function normally on
disconnect.