How do you attach a lens to the RFD77402 as mentioned in section 6 of the datasheet?
The Qwiic connectors/JSTs are higher than the sensor so you can either hot air off the JSTs and glue acrylic to the FR4 base with silicon. Or you could leave the JSTs on leaving a 2mm air gap between the face of the RFD77402 and the cover glass. It's not known how the air gap will affect overall read range.
The text was updated successfully, but these errors were encountered:
How do you attach a lens to the RFD77402 as mentioned in section 6 of the datasheet?
The Qwiic connectors/JSTs are higher than the sensor so you can either hot air off the JSTs and glue acrylic to the FR4 base with silicon. Or you could leave the JSTs on leaving a 2mm air gap between the face of the RFD77402 and the cover glass. It's not known how the air gap will affect overall read range.