You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Establish front panel circuit and connect mounting holes to it.
Power connector - it was pointed out in Power supplu connector - panel isolation #91 that power connector in a current setup connects to the panel and, as a consequence can connect to GND via microUSB port or SFP cage effectively diminishing effect of EMI filters (FL1, FL2). As a solution we could pull the connector back and increase FP cutout, so that insulating sleeve can fit between connector and front panel. This would mean lack of nut, but should not be a problem.
microUSB shield should be connected to FP circuit and disconnected from GND.
SMA stays as it is.
Connect SFP cages to FP circuit.
The text was updated successfully, but these errors were encountered:
What does power source characterization has to do with it? Isn't it only the matter of consequent separation of chassis circuit from the module's ground?
Not only, but It also creates the common mode noise that is propagated across the crate via a ground loop it creates with the AC network.
There are many more such loops that are not obvious.
Depends on the final conclusions of sinara-hw/meta#64.
There are several points to consider:
The text was updated successfully, but these errors were encountered: