* Copyright © 2017-2022 Matt Robinson
*
* SPDX-License-Identifier: GPL-3.0-or-later
*/
#include <iostream>
#include <thread>
#include <syslog.h>
#include "Boiler.h"
#include "LogLimit.h"
const std::chrono::hours IDENTIFY_INTERVAL(12);
const std::chrono::milliseconds SAMPLE_INTERVAL(500);
const std::chrono::minutes COUNTERS_INTERVAL(1);
void logToStdout(const std::string &message)
{
std::cout << message << std::endl;
}
void logToSyslog(const std::string &message)
{
syslog(LOG_NOTICE, "%s", message.c_str());
}
int main(int argc, const char* const argv[])
{
if(argc < 2 || argc > 3 || (argc == 3 && std::string(argv[1]) != "-d"))
{
std::cerr << "Usage: boiler-logger [-d] <port>" << std::endl;
return EXIT_FAILURE;
}
if(argc == 3)
{
LogLimitValue::LogFunc = logToStdout;
}
else
{
LogLimitValue::LogFunc = logToSyslog;
openlog(NULL, LOG_CONS | LOG_PID | LOG_NDELAY, LOG_USER);
}
Boiler boiler(argv[argc - 1]);
std::chrono::time_point<std::chrono::steady_clock> lastIdentify(-IDENTIFY_INTERVAL);
std::chrono::time_point<std::chrono::steady_clock> lastCounters(-COUNTERS_INTERVAL);
std::chrono::time_point<std::chrono::steady_clock> lastSample(-SAMPLE_INTERVAL);
LogLimit trackIdentifyVals;
LogLimit trackCountersVals;
LogLimit trackSampleVals;
while(true)
{
auto difference = std::chrono::steady_clock::now() - lastIdentify;
if(difference >= IDENTIFY_INTERVAL)
{
lastIdentify = std::chrono::steady_clock::now();
IdentifyMessage identify = boiler.ReadIdentifyData();
trackIdentifyVals.NewValues(identify.getValues());
}
difference = std::chrono::steady_clock::now() - lastCounters;
if(difference >= COUNTERS_INTERVAL)
{
lastCounters = std::chrono::steady_clock::now();
CountersMessage counters = boiler.ReadCountersData();
trackCountersVals.NewValues(counters.getValues());
}
difference = std::chrono::steady_clock::now() - lastSample;
std::this_thread::sleep_for(SAMPLE_INTERVAL - difference);
lastSample = std::chrono::steady_clock::now();
SampleMessage sample = boiler.ReadSampleData();
trackSampleVals.NewValues(sample.getValues());
}
return EXIT_SUCCESS;
}