Information about Values

Raomin edited this page Jan 14, 2021 · 33 revisions

Edit this page to enter your comments on the values.

Occurences Registry Name Comments
19 0x00,0,152,1,-1 Sensor Data Qty
1 0x00,0,405,0,-1 *Refrigerant type
12 0x00,0,801,0,-1 *Refrigerant type
6 0x00,0,802,0,-1 *Refrigerant type
6 0x00,0,995,1,-1
32 0x00,0,995,1,-1 NextDataGrid
9 0x00,0,996,0,-1 Override All Clear
3 0x00,0,998,1,-1
16 0x00,0,998,1,-1 In-Out separator
19 0x00,1,152,1,-1 INV compressor Qty
9 0x00,1,996,1,-1 Override CMD:0x00 N_INV=1
18 0x00,10,152,1,-1 O/U MPU ID (xx)
1 0x00,10,213,1,-1 O/U MPU ID
18 0x00,11,152,1,-1 O/U MPU ID (yy)
1 0x00,11,213,1,-1 O/U MPU ID
18 0x00,12,105,1,-1 O/U capacity (kW)
1 0x00,2,152,1,-1 STD Compressor
18 0x00,2,152,1,-1 STD compressor Qty
9 0x00,2,996,0,-1 Override CMD:0x00 N_STD=0
19 0x00,3,152,1,-1 Fan Data Qty
9 0x00,3,996,2,-1 Override CMD:0x00 N_FAN=2
19 0x00,4,152,1,-1 Expansion Valve Data Qty
2 0x00,4,996,1,-1 Override CMD:0x00 N_EV=1
7 0x00,4,996,2,-1 Override CMD:0x00 N_EV=2
19 0x00,5,152,1,-1 4 Way Valve Data Qty
9 0x00,5,996,1,-1 Override CMD:0x00 N_20S=1
19 0x00,6,152,1,-1 Crank Case Heater Qty
9 0x00,6,996,1,-1 Override CMD:0x00 N_CH=1
19 0x00,7,152,1,-1 Solenoid valve Qty
9 0x00,7,996,3,-1 Override CMD:0x00 N_SV=3
19 0x00,8,152,1,-1 Max. connectable indoor units
19 0x00,9,152,1,-1 Connected Indoor Unit Qty
19 0x10,0,217,1,-1 Operation Mode
19 0x10,1,300,1,-1 Low noise control
19 0x10,1,301,1,-1 Demand Signal
19 0x10,1,302,1,-1 Pressure equalizing operation
19 0x10,1,303,1,-1 Oil Return Operation
19 0x10,1,304,1,-1 Defrost Operation
19 0x10,1,305,1,-1 Startup Control
19 0x10,1,306,1,-1 Restart standby
19 0x10,1,307,1,-1 Thermostat ON/OFF
19 0x10,10,303,1,-1 Comp. INV Current Drop
19 0x10,10,307,1,-1 Discharge Temp. Drop
19 0x10,10,310,1,-1 Discharge Temp. Protection Retry Qty
19 0x10,10,311,1,-1 Comp. INV Current Protection Retry Qty
19 0x10,11,303,1,-1 LP Drop Control
19 0x10,11,307,1,-1 HP Drop Control
19 0x10,11,310,1,-1 HP Protection Retry Qty
19 0x10,11,311,1,-1 LP Protection Retry Qty
1 0x10,12,303,1,-1 Other Control
18 0x10,12,303,1,-1 Other Drop Control
18 0x10,12,307,1,-1 Fin Temp. Drop Control
18 0x10,12,310,1,-1 Fin Temp. Protection Retry Qty
18 0x10,12,311,1,-1 Not in use
1 0x10,2,300,1,-1 Other control 8
1 0x10,2,301,1,-1 Other control 7
1 0x10,2,302,1,-1 Other control 6
1 0x10,2,303,1,-1 Other control 5
1 0x10,2,304,1,-1 Other control 4
1 0x10,2,305,1,-1 Other control 3
1 0x10,2,306,1,-1 Other control 2
1 0x10,2,307,1,-1 Other control 1
1 0x10,3,300,1,-1 Other control 16
1 0x10,3,301,1,-1 Other control 15
1 0x10,3,302,1,-1 Other control 14
1 0x10,3,303,1,-1 Other control 13
1 0x10,3,304,1,-1 Other control 12
1 0x10,3,305,1,-1 Other control 11
1 0x10,3,306,1,-1 Other control 10
1 0x10,3,307,1,-1 Other control 9
19 0x10,4,203,1,-1 Error type
19 0x10,5,204,1,-1 Error Code
1 {0x10,6,114,2,1 Target Discharge Temp.
18 {0x10,6,114,2,1 Target Evap. Temp.
19 {0x10,8,114,2,1 Target Cond. Temp.
18 0x11,0,215,1,-1 O/U EEPROM (1st digit)
18 0x11,1,215,1,-1 O/U EEPROM (3rd 4th digit)
18 0x11,2,215,1,-1 O/U EEPROM (5th 6th digit)
18 0x11,3,215,1,-1 O/U EEPROM (7th 8th digit)
18 0x11,4,215,1,-1 O/U EEPROM (10th digit)
18 0x11,5,214,1,-1 O/U EEPROM (11th digit)
3 {0x20,0,105,2,1 Outdoor air temp.
16 {0x20,0,105,2,1 Outdoor air temp.(R1T)
2 {0x20,10,105,2,1 Leaving brine temp.(R6T)
4 {0x20,10,105,2,1 Liquid pipe temp.
12 {0x20,10,105,2,1 Liquid pipe temp.(R6T)
1 {0x20,10,105,2,1 Liquid temperature(R3T)
1 {0x20,12,105,2,1 Fin Temp.
10 {0x20,12,105,2,1 Heat sink temp.
1 {0x20,12,105,2,1 Heat sink temp.(R10T)
3 {0x20,12,105,2,1 INV fin temp.
4 {0x20,12,105,2,2 High Pressure
3 {0x20,12,405,2,1 High Pressure(T)
6 {0x20,14,105,2,2 Low Pressure
3 {0x20,14,105,2,2 Pressure sensor
10 {0x20,14,105,2,2 Pressure
5 {0x20,14,405,2,1 Low Pressure(T)
3 {0x20,14,405,2,1 Pressure sensor(T)
10 {0x20,14,405,2,1 Pressure(T)
5 0x20,16,105,2,-1 Not in use
1 0x20,16,105,2,-1 Sensor data 9
5 0x20,18,105,2,-1 Not in use
1 0x20,18,105,2,-1 Sensor data 10
2 {0x20,2,105,2,1 2 phase thermistor (R4T)
15 {0x20,2,105,2,1 O/U Heat Exch. Temp.
2 {0x20,2,105,2,1 Outdoor heat exchanger temp.
1 0x20,20,105,2,-1 Sensor data 11
19 {0x20,4,105,2,1 Discharge pipe temp.
1 {0x20,6,105,2,1 Suction Pipe Temperature
16 {0x20,6,105,2,1 Suction pipe temp.
2 {0x20,6,105,2,1 Suction pipe temp.(R3T)
2 {0x20,8,105,2,1 Entering brine temp.(R5T)
13 {0x20,8,105,2,1 Heat exchanger mid-temp.
2 {0x20,8,105,2,1 O/U Heat Exch. Mid-temp.
2 {0x20,8,105,2,1 Outdoor heat exchanger mid temp.
19 0x21,0,105,2,-1 INV primary current (A)
1 0x21,0,105,2,-1 INV secondary current (A)
1 0x21,10,105,2,-1 Sensor data 6
3 {0x21,10,105,2,1 Compressor outlet temperature
1 {0x21,10,105,2,1 Refrig. temp. evap.Out
1 {0x21,10,152,2,1 Compressor outlet temperature
13 {0x21,11,105,2,1 Refrig. temp. evap. In
1 0x21,12,105,2,-1 Sensor data 7
1 {0x21,12,105,2,1 Refrig. temp. evap.Out
13 {0x21,13,105,2,1 Refrig. temp. evap.Out
1 0x21,14,105,2,-1 Sensor data 8
14 0x21,15,105,1,-1 Not in use
14 0x21,16,105,1,-1 Not in use
1 0x21,16,105,2,-1 Sensor data 9
14 0x21,17,105,1,-1 Not in use
14 0x21,18,105,1,-1 Not in use
1 0x21,18,105,2,-1 Sensor data 10
1 0x21,2,101,2,-1 Voltage (N-phase) (V)
18 0x21,2,105,2,-1 INV secondary current (A)
1 0x21,20,105,2,-1 Sensor data 11
11 0x21,4,101,2,-1 Voltage (N-phase) (V)
2 0x21,4,101,2,-1 Voltage (V)
1 {0x21,4,105,2,1 Brine inlet temp.
5 {0x21,4,105,2,1 INV fin temp.
1 0x21,6,105,2,-1 Sensor data 4
1 {0x21,6,105,2,1 Brine inlet temp.
1 {0x21,6,105,2,1 Brine outlet temp.
2 {0x21,6,105,2,1 Fan1 Fin temp.
1 {0x21,6,152,2,1 Fan1 Fin temp.
13 0x21,6,300,1,-1 Not in use
13 0x21,6,301,1,-1 Not in use
13 0x21,6,302,1,-1 Not in use
13 0x21,6,303,1,-1 Not in use
13 0x21,6,304,1,-1 Not in use
13 0x21,6,305,1,-1 Not in use
13 0x21,6,306,1,-1 Not in use
13 0x21,6,307,1,-1 Brine Flow Switch
13 {0x21,7,105,2,1 Brine inlet temp.
1 0x21,8,105,2,-1 Sensor data 5
1 {0x21,8,105,2,1 Brine outlet temp.
2 {0x21,8,105,2,1 Fan2 Fin temp.
1 {0x21,8,105,2,1 Refrig. temp. evap. In
1 {0x21,8,152,2,1 Fan2 Fin temp.
13 {0x21,9,105,2,1 Brine outlet temp.
8 {0x*,0,151,2,-1 Expansion valve (pls)
2 {0x*,0,151,2,-1 Expansion valve 1 (pls)
10 {0x*,0,152,1,-1 INV frequency (rps)
3 {0x*,0,211,1,-1 Fan 1 (10 rpm)
7 {0x*,0,211,1,-1 Fan 1 (step)
10 {0x*,0,303,1,-1 4 Way Valve 5
1 {0x*,0,303,1,-1 Crank case heater 5
10 {0x*,0,303,1,-1 Solenoid Valve 5
10 {0x*,0,304,1,-1 4 Way Valve 4
10 {0x*,0,304,1,-1 Crank case heater 4
10 {0x*,0,304,1,-1 Solenoid Valve 4
10 {0x*,0,305,1,-1 4 Way Valve 3
10 {0x*,0,305,1,-1 Crank case heater 3
10 {0x*,0,305,1,-1 Solenoid Valve 3
10 {0x*,0,306,1,-1 4 Way Valve 2
10 {0x*,0,306,1,-1 Crank case heater 2
10 {0x*,0,306,1,-1 STD Compressor 2
2 {0x*,0,306,1,-1 SV (BPH)
1 {0x*,0,306,1,-1 SV2 (BPH)
7 {0x*,0,306,1,-1 Solenoid Valve 2
8 {0x*,0,307,1,-1 4 Way Valve 1
2 {0x*,0,307,1,-1 4 Way Valve
8 {0x*,0,307,1,-1 Crank case heater 1
2 {0x*,0,307,1,-1 Crank case heater
10 {0x*,0,307,1,-1 STD Compressor 1
1 {0x*,0,307,1,-1 SV (hot Gas)
1 {0x*,0,307,1,-1 SV1 (hot gas)
8 {0x*,0,307,1,-1 Solenoid Valve 1
10 {0x*,1,152,1,-1 INV frequency 2 (rps)
10 {0x*,1,211,1,-1 Fan 2 (step)
10 {0x*,2,151,2,-1 Expansion valve 2 (pls)
10 {0x*,4,151,2,-1 Expansion valve 3 (pls)
10 {0x*,6,151,2,-1 Expansion valve 4 (pls)
10 {0x*,8,151,2,-1 Expansion valve 5 (pls)
8 0x30,0,152,1,-1 INV frequency (rps)
1 0x30,0,152,1,-1 INV frequency 1 (rps)
1 0x30,0,303,1,-1 Solenoid Valve 5
1 0x30,0,304,1,-1 Solenoid Valve 4
1 0x30,1,211,1,-1 Brine pump feedback
3 0x30,1,211,1,-1 Fan 1 (10 rpm)
5 0x30,1,211,1,-1 Fan 1 (step)
1 {0x30,10,105,1,1 Inlet water temp. (DMW)
1 {0x30,10,113,1,1 Inlet water temp. (DMW)
1 0x30,10,306,1,-1 Solenoid Valve 10
1 0x30,10,307,1,-1 Solenoid Valve 9
1 {0x30,11,105,1,1 Outlet water hex temp. before BUH (DLWB2)
1 {0x30,11,113,1,1 Outlet water hex temp. before BUH (DLWB2)
3 0x30,11,307,1,-1 4 Way Valve
3 0x30,12,307,1,-1 Crank case heater
3 0x30,13,305,1,-1 Y3S
1 0x30,13,306,1,-1 LP bypass valve (Y2S)
1 0x30,13,306,1,-1 SV (drain pan heater)
1 0x30,13,306,1,-1 Y2S
1 0x30,13,307,1,-1 4 way valve (Y1S)
1 0x30,13,307,1,-1 Hot gas bypass valve (Y3S)
1 0x30,13,307,1,-1 Y1S
2 0x30,2,151,2,-1 Expansion valve (pls)
6 0x30,2,211,1,-1 Fan 2 (step)
1 0x30,2,211,1,-1 Not in use
7 0x30,3,151,2,-1 Expansion valve 1 (pls)
2 0x30,4,303,1,-1 4 Way Valve 5
2 0x30,4,304,1,-1 4 Way Valve 4
2 0x30,4,305,1,-1 4 Way Valve 3
2 0x30,4,306,1,-1 4 Way Valve 2
2 0x30,4,307,1,-1 4 Way Valve 1
7 0x30,5,151,2,-1 Expansion valve 2 (pls)
3 0x30,7,151,2,-1 Expansion valve 3 (pls)
1 0x30,7,300,1,-1 4 Way Valve 8
1 0x30,7,301,1,-1 4 Way Valve 7
1 0x30,7,302,1,-1 4 Way Valve 6
3 0x30,7,303,1,-1 4 Way Valve 5
3 0x30,7,304,1,-1 4 Way Valve 4
3 0x30,7,305,1,-1 4 Way Valve 3
4 0x30,7,306,1,-1 4 Way Valve 2
4 0x30,7,307,1,-1 4 Way Valve 1
1 0x30,8,303,1,-1 Crank case heater 5
2 0x30,8,304,1,-1 Crank case heater 4
2 0x30,8,305,1,-1 Crank case heater 3
3 0x30,8,306,1,-1 Crank case heater 2
3 0x30,8,307,1,-1 Crank case heater 1
1 0x30,8,307,1,-1 Crank case heater
3 0x30,9,151,2,-1 Expansion valve 4 (pls)
1 0x30,9,300,1,-1 Solenoid Valve 8
1 0x30,9,301,1,-1 Solenoid Valve 7
1 0x30,9,302,1,-1 Solenoid Valve 6
3 0x30,9,303,1,-1 Solenoid Valve 5
3 0x30,9,304,1,-1 Solenoid Valve 4
3 0x30,9,305,1,-1 Solenoid Valve 3
1 {0x30,9,305,1,1 Solenoid Valve 3
1 0x30,9,306,1,-1 SV2 (BPH)
2 0x30,9,306,1,-1 Solenoid Valve 2
1 {0x30,9,306,1,1 LP bypass valve (Y3S)
1 0x30,9,307,1,-1 SV1 (hot gas)
2 0x30,9,307,1,-1 Solenoid Valve 1
1 {0x30,9,307,1,1 Hot gas bypass valve (Y2S)
1 0x3x,0,306,1,-1 STD Compressor 2
1 0x3x,0,307,1,-1 STD Compressor 1
1 0x3x,1,152,1,-1 INV frequency 2 (rps)
18 0x60,0,304,1,-1 Data Enable/Disable
1 0x60,0,307,1,-1 Data Enable/Disable
19 0x60,1,152,1,-1 Indoor Unit Address
19 0x60,11,300,1,-1 Bivalent Operation
19 0x60,11,301,1,-1 Not in use
19 0x60,11,302,1,-1 Not in use
19 0x60,11,303,1,-1 Solar input
18 0x60,11,304,1,-1 Benefit kWh rate power supply
1 0x60,11,304,1,-1 HP tariff input
1 0x60,11,305,1,-1 Clixon BSH
18 0x60,11,305,1,-1 Thermal protector BSH
1 0x60,11,306,1,-1 Clixon BUH
2 0x60,11,306,1,-1 Thermal Protector BUH
16 0x60,11,306,1,-1 Thermal protector (Q1L) BUH
1 0x60,11,307,1,-1 Flow Switch
18 0x60,11,307,1,-1 Water flow switch
1 0x60,12,300,1,-1 Solar Output Signal
18 0x60,12,300,1,-1 Solar pump operation
1 0x60,12,301,1,-1 Pump Output
18 0x60,12,301,1,-1 Water pump operation
9 0x60,12,302,1,-1 BPH
1 0x60,12,302,1,-1 Bottom Plate Heater
9 0x60,12,302,1,-1 Floor loop shut off valve
18 0x60,12,303,1,-1 BUH Step2
1 0x60,12,303,1,-1 BUH2
18 0x60,12,304,1,-1 BUH Step1
1 0x60,12,304,1,-1 BUH1
19 0x60,12,305,1,-1 BSH
18 0x60,12,306,1,-1 3way valve(On:DHW_Off:Space)
1 0x60,12,306,1,-1 4way Valve(Space/DHW)
18 0x60,12,307,1,-1 2way valve(On:Heat_Off:Cool)
1 0x60,12,307,1,-1 3way Valve(Cool/Heat)
18 0x60,13,152,1,-1 Indoor Option Code
1 0x60,13,212,1,-1 Indoor Option Code
18 0x60,14,215,1,-1 I/U Software ID (yy)
1 0x60,14,314,2,-1 Indoor Software Version
1 0x60,15,212,1,-1 Indoor EEPROM Version
18 0x60,15,215,1,-1 I/U Software ID (xx)
18 0x60,16,152,1,-1 I/U EEPROM Ver.
19 0x60,2,300,1,-1 Freeze Protection for water piping
19 0x60,2,301,1,-1 Silent Mode
19 0x60,2,302,1,-1 Freeze Protection
19 0x60,2,303,1,-1 Thermostat ON/OFF
18 0x60,2,315,1,-1 I/U operation mode
1 0x60,2,315,1,-1 Indoor Operation Mode
19 0x60,3,204,1,-1 Error Code
11 0x60,4,152,1,-1 Error detailed code
2 0x60,4,152,2,-1 Indoor Unit Code
6 0x60,4,314,2,-1 Indoor Unit Code
11 0x60,5,203,1,-1 Error type
17 0x60,6,219,1,-1 I/U capacity code
2 0x60,6,219,1,-1 Indoor Unit Capacity
18 {0x60,7,105,2,1 DHW setpoint
1 {0x60,7,105,2,1 R/C Setpoint
1 {0x60,9,105,2,1 H/P Outlet Setpoint
18 {0x60,9,105,2,1 LW setpoint (main)
19 0x61,0,307,1,-1 Data Enable/Disable
19 0x61,1,152,1,-1 Indoor Unit Address
18 {0x61,10,105,2,1 DHW tank temp. (R5T)
1 {0x61,10,105,2,1 DHW temperature(R5T)
16 {0x61,12,105,2,1 Indoor ambient temp. (R1T)
2 {0x61,12,105,2,1 RT Temp.
1 {0x61,12,105,2,1 Remocon thermistor
2 {0x61,13,105,2,1 Ext. indoor ambient sensor (R6T)
13 {0x61,14,105,2,1 Ext. indoor ambient sensor (R6T)
2 {0x61,14,105,2,1 Outdoor Ambient or Ext Sensor
15 {0x61,2,105,2,1 Leaving water temp. before BUH (R1T)
1 {0x61,2,105,2,1 Outlet PHE(R1T)
3 {0x61,2,105,2,1 Outlet Water Heat Exch. Temp. (R1T)
15 {0x61,4,105,2,1 Leaving water temp. after BUH (R2T)
1 {0x61,4,105,2,1 Outlet BUH(R2T)
3 {0x61,4,105,2,1 Outlet Water BUH Temp. (R2T)
1 {0x61,6,105,2,1 Liquid temperature(R3T)
18 {0x61,6,105,2,1 Refrig. Temp. liquid side (R3T)
1 {0x61,8,105,2,1 Inlet temperature(R4T)
18 {0x61,8,105,2,1 Inlet water temp.(R4T)
18 0x62,0,307,1,-1 Data Enable/Disable
18 0x62,1,152,1,-1 Indoor Unit Address
18 {0x62,11,105,1,2 Water pressure
18 0x62,12,152,1,-1 Water pump signal (0:max-100:stop)
2 0x62,13,152,1,-1 3 way Valve Mixing 1
16 0x62,13,152,1,-1 [Future] 3 way Valve Mixing 1
2 0x62,14,152,1,-1 3 way Valve Mixing 2
16 0x62,14,152,1,-1 [Future] 3 way Valve Mixing 2
1 {0x62,15,105,2,2 Pressure sensor
3 {0x62,15,105,2,2 Refrigerant pressure sensor
10 0x62,15,152,1,-1 Not in use
1 0x62,15,152,2,-1 Not in use
3 {0x62,15,152,2,2 Refrigerant pressure sensor
10 0x62,16,300,1,-1 Not in use
10 0x62,16,301,1,-1 Not in use
10 0x62,16,302,1,-1 Not in use
10 0x62,16,303,1,-1 Not in use
10 0x62,16,304,1,-1 Not in use
10 0x62,16,305,1,-1 Not in use
10 0x62,16,306,1,-1 Not in use
10 0x62,16,307,1,-1 Not in use
1 0x62,17,300,1,-1 Not in use
1 0x62,17,301,1,-1 Not in use
1 0x62,17,302,1,-1 Not in use
1 0x62,17,303,1,-1 Not in use
1 0x62,17,304,1,-1 Not in use
1 0x62,17,305,1,-1 Not in use
1 0x62,17,306,1,-1 Not in use
1 0x62,17,307,1,-1 Not in use
18 0x62,2,300,1,-1 Emergency (indoor) active/not active
18 0x62,2,301,1,-1 Not in use
18 0x62,2,302,1,-1 System OFF (ON:System off)
18 0x62,2,303,1,-1 Space heating Operation ON/OFF
18 0x62,2,304,1,-1 Powerful DHW Operation. ON/OFF
18 0x62,2,305,1,-1 Storage comfort ON/OFF
18 0x62,2,306,1,-1 Storage eco ON/OFF
18 0x62,2,307,1,-1 Reheat ON/OFF
18 {0x62,3,105,2,1 LW setpoint (add)
18 {0x62,5,105,2,1 RT setpoint
18 0x62,7,300,1,-1 Pwr consumption limit 1
18 0x62,7,301,1,-1 Pwr consumption limit 2
18 0x62,7,302,1,-1 Pwr consumption limit 3
18 0x62,7,303,1,-1 Pwr consumption limit 4
18 0x62,7,304,1,-1 Main RT Heating
18 0x62,7,305,1,-1 Main RT Cooling
18 0x62,7,306,1,-1 Add. Ext. RT Input Heat.
18 0x62,7,307,1,-1 Add. Ext. RT Input Cool.
2 0x62,8,300,1,-1 Space C/H Op. or BPH
16 0x62,8,300,1,-1 Space H Operation output
18 0x62,8,301,1,-1 Alarm output
18 0x62,8,302,1,-1 Circulation pump operation
2 0x62,8,303,1,-1 Mode conflict
1 0x62,8,303,1,-1 Not in use
15 0x62,8,303,1,-1 Tank preheat ON/OFF
2 0x62,8,304,1,-1 DHW priority request
10 0x62,8,304,1,-1 Not in use
6 0x62,8,304,1,-1 PHE Heater
16 0x62,8,305,1,-1 Not in use
2 0x62,8,305,1,-1 Powerful demand
2 0x62,8,306,1,-1 Defrost prohibition ON/OFF
16 0x62,8,306,1,-1 Not in use
18 0x62,8,307,1,-1 None
18 0x62,9,105,2,-1 Flow sensor (l/min)
18 0x63,0,307,1,-1 Data Enable/Disable
18 0x63,1,152,1,-1 Indoor Unit Address
2 0x63,10,215,1,-1 Not in use
2 0x63,11,215,1,-1 Not in use
2 0x63,12,215,1,-1 Not in use
1 0x63,13,152,1,-1 BUH output capacity
2 0x63,13,311,1,-1 BUH output capacity
3 0x63,14,161,1,-1 Current measured by CT sensor of L1
3 0x63,15,161,1,-1 Current measured by CT sensor of L2
3 0x63,16,161,1,-1 Current measured by CT sensor of L3
3 0x63,16,307,1,-1 HP Forced FG
1 0x63,16,307,1,-1 HP is operation forced OFF by installer
18 0x63,2,215,1,-1 I/U EEPROM (3rd digit)
18 0x63,3,215,1,-1 I/U EEPROM (4th 5th digit)
18 0x63,4,215,1,-1 I/U EEPROM (6th 7th digit)
18 0x63,5,215,1,-1 I/U EEPROM (8th 9th digit)
18 0x63,6,215,1,-1 I/U EEPROM (11th digit)
16 0x63,7,214,1,-1 I/U EEPROM (12th digit)(rev.)
2 0x63,7,215,1,-1 I/U EEPROM (12th digit)(rev.)
2 0x63,8,215,1,-1 Not in use
2 0x63,9,215,1,-1 Not in use
17 0x64,0,307,1,-1 Data Enable/Disable
17 0x64,1,152,1,-1 Indoor Unit Address
7 {0x64,10,105,2,1 Mixed water temp.
7 {0x64,10,118,2,1 Mixed water temp.(R7T)
8 {0x64,12,105,2,1 2nd Domestic hot water temperature
1 0x64,14,152,1,-1 Target delta T heating
7 {0x64,14,152,1,1 Target delta T heating
1 0x64,15,152,1,-1 Target delta T cooling
7 {0x64,15,152,1,1 Target delta T cooling
3 0x64,2,300,1,-1 Hybrid DHW operation mode
17 0x64,2,301,1,-1 Bypass Valve Output
17 0x64,2,302,1,-1 Boiler DHW Demand
17 0x64,2,303,1,-1 Boiler Operation Demand
17 0x64,2,316,1,-1 Hybrid Op. Mode
17 0x64,3,105,2,-1 BE_COP
17 {0x64,5,105,2,1 Hybrid Heating Target Temp.
17 {0x64,7,105,2,1 Boiler Heating Target Temp.
2 0x64,9,300,1,-1 Main pump
2 0x64,9,301,1,-1 Add pump
12 0x64,9,301,1,-1 Main pump
12 0x64,9,302,1,-1 Add pump
2 {0xA0,0,119,2,1 Suction temp
2 0xA0,10,152,1,-1 O/U MPU ID
2 0xA0,11,152,1,-1 O/U MPU ID
2 0xA0,12,300,1,-1 52C Output
2 0xA0,12,301,1,-1 4 way valve (Y1S)
1 {0xA0,12,301,1,1 4 way valve (Y1S)
2 0xA0,12,302,1,-1 Solenoid Valve 1
1 0xA0,12,303,1,-1 SV (drain pan heater)
1 0xA0,12,303,1,-1 Solenoid Valve 2
2 0xA0,12,304,1,-1 Solenoid Valve 3
2 0xA0,12,305,1,-1 Crank case heater
2 0xA0,12,306,1,-1 Safeguard operation
2 0xA0,12,307,1,-1 HPS operation
2 0xA0,13,300,1,-1 Powerful bit (MT setting bit)
2 0xA0,13,301,1,-1 Indoor unit blowout 50 ° C flag
2 0xA0,13,302,1,-1 During emergency operation
2 0xA0,13,303,1,-1 Discharge Temp. Drop
2 {0xA0,14,105,2,1 Compressor port temperature
2 {0xA0,2,119,2,1 Outdoor heat exchanger temp.
2 {0xA0,4,119,2,1 Liquid pipe temp.
2 {0xA0,6,119,2,2 Pressure
2 0xA0,8,151,2,-1 Expansion valve 3 (pls)
3 {0xA1,0,119,2,1 Water heat exchanger inlet temp.
3 {0xA1,2,119,2,1 Water heat exchanger outlet temp.
3 0xA1,4,300,1,-1 PHE Heater
3 0xA1,4,301,1,-1 Bottom Plate Heater
2 0xA1,4,302,1,-1 Liquid INJ solenoid valve (Y4S)
2 {0xA1,5,114,2,1 Target Discharge Temp.
2 {0xA1,7,114,2,1 Target port temperature
2 0xA1,9,300,1,-1 Alterma LT setting
2 0xA1,9,301,1,-1 Hydro split setting
2 0xA1,9,302,1,-1 GSHP setting
2 0xA1,9,303,1,-1 MT setting
2 0xA1,9,304,1,-1 Minichiller setting
2 0xA1,9,305,1,-1 Monobloc setting