Added phase-dependent particle options to LAM #4369
Conversation
Codecov ReportAttention: Patch coverage is
Additional details and impacted files@@ Coverage Diff @@
## develop #4369 +/- ##
===========================================
- Coverage 99.41% 99.41% -0.01%
===========================================
Files 292 292
Lines 22213 22223 +10
===========================================
+ Hits 22084 22093 +9
- Misses 129 130 +1 ☔ View full report in Codecov by Sentry. |
Check out this pull request on See visual diffs & provide feedback on Jupyter Notebooks. Powered by ReviewNB |
# and options["particle mechanics"] == "none" | ||
# and options["loss of active material"] == "none" |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Does this need to be put back or deleted?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This needs to be deleted.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hi Caitlin,
This is a capability that PyBaMM has required for some time, so thank you very much for taking the time to add it! A couple of small changes are required, and I also have some deeper questions.
Required changes
- The reason the integration tests are failing is that the volume change functions you added take
sto
andc_s_max
as arguments, when this parameter only takessto
as an argument. Removingc_s_max
as an argument will fix this. - The thickness changes are being added up in the wrong order. Phases should also be added before domains. Also, this code is not covered by any tests.
Broader questions
- I dispute your assertion that no parameter set exists for composite degradation. This paper from @mbonkile has one.
- Do you know why the model doesn't conserve lithium precisely?
Many thanks, Simon
@DrSOKane thanks for your input. I updated the code as you suggested. For the degradation parameter set, I meant that there wasn't an available parameter set in pybamm to cover a composite electrode with LAM. It would be great to add the parameter set from the paper you referenced. I'm not sure what's behind the drop in accuracy for lithium conservation. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hi Caity, thanks for fixing these! We definitely need a Bonkile2024
parameter set, but that can be a separate PR. I'm still concerned about conservation, but there is precedent for allowing 9 digits, and so I will now approve the changes for merging.
Description
Please include a summary of the change and which issue is fixed. Please also include relevant motivation and context. List any dependencies that are required for this change.
Fixes # (issue)
Type of change
Please add a line in the relevant section of CHANGELOG.md to document the change (include PR #) - note reverse order of PR #s. If necessary, also add to the list of breaking changes.
Key checklist:
$ pre-commit run
(or$ nox -s pre-commit
) (see CONTRIBUTING.md for how to set this up to run automatically when committing locally, in just two lines of code)$ python run-tests.py --all
(or$ nox -s tests
)$ python run-tests.py --doctest
(or$ nox -s doctests
)You can run integration tests, unit tests, and doctests together at once, using
$ python run-tests.py --quick
(or$ nox -s quick
).Further checks: